Tianjin Zhibo Lian Testing Instrument Sales Co., Ltd
Home>Products>Where to sell coating thickness gauges in Tianjin - Coating thickness gauge prices
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18222639567
  • Address
    No. 1-188, Ligang Park, Shuanggang Industrial Zone, Jinnan District, Tianjin
Contact Now
Where to sell coating thickness gauges in Tianjin - Coating thickness gauge prices
Our company operates various types of coating thickness gauges, suitable for metal coatings, wood, plastic, concrete coatings, steel structure firepro
Product details
detailed information
  • Product features: Complete variety
  • Whether to import: No
  • Origin: Tianjin
  • Customized processing: No
  • Brand: Tianjin Huayin
  • Model: Thickness Gauge
  • Measurement range: 0-11000 micrometers
  • Measurement accuracy: 0.1 micrometers
  • Size: 102x66x24mm
  • Weight: 0.2kg
  • Cross border source: No

Coating thickness gauge HY-200FA (iron substrate)

The coating thickness gauge is a magnetic instrument with a wide range of applications, and its technical parameters fully comply with national standards.

This instrument is a magnetic portable coating thickness gauge that uses magnetic induction testing method to quickly, non destructively, and accurately test the thickness of non-magnetic coatings and plating on magnetic substrates.

It can be used in both laboratories and engineering sites. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields.

It is an essential instrument for material protection professionals.
Fe probes can detect the thickness of all non-magnetic coatings, such as paints, powder coatings, plastics, ceramics, chromium, copper, zinc, etc. applied to steel and iron.

Function of coating thickness gauge:

The magnetic thickness measurement method is used to measure the thickness of the non-magnetic coating layer on the magnetic metal substrate;
The instrument can be calibrated using two methods: single point calibration and two-point calibration;

Basic calibration correction method can be used to update and correct the system errors of the measuring head, ensuring the accuracy of the instrument during the measurement process;

Negative display function ensures the accuracy of instrument zero point calibration and improves testing precision;
● There is a buzzing sound during the operation process to prompt;

● Two shutdown modes: manual shutdown mode and automatic shutdown mode;

● Battery voltage indication: low voltage prompt;

● Micro power design, with a current of less than 10 microamperes in standby mode;
Measurement method: F-magnetic induction.


Basic working principle of magnetic method

Technical parameters of coating thickness gauge:
Measurement range: 0~1500um

Resolution: 0.1/1

***Small curved surface: convex 5mm/concave 5mm

***Small measurement area: 10 × 10mm

***Thin substrate: 0.4mm

Usage environment: Temperature: 0-40 ℃ Humidity: 10-85% RH

Measurement accuracy error: zero calibration ± (1+3% H); Two point calibration ± [(1%~3% H)] H+1.5

Metric/Imperial: Convertible Body Size: 102mm x 66mm x24mm

Power supply: 2 No. 5 batteries

Weight: 99g (including battery)

Coating thickness gauge accessories:

5 standard films: 50 μ m, 100 μ m, 250 μ m, 500 μ m, 1000 μ m (optional: 12 μ m, 25 μ m)

1 piece of substrate (iron substrate)

1 copy of instruction manual

2 batteries

1 warranty card


Introduction to TT220 Coating Thickness Gauge
The TT220 coating thickness gauge adopts the magnetic thickness measurement method, which can quickly, non destructively, and accurately measure the coating thickness on ferromagnetic metal substrates.

It can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields. Due to its small size and integrated probe, this instrument is particularly suitable for on-site engineering measurements.
TT220 Coating Thickness GaugeMain functions:
Zero point calibration and two-point calibration can be performed.
Basic calibration can be performed on the measuring head.
There are five statistical measures: mean(MEAN)Value(MAX)* * * * Small value(MIN)Test frequency(NO)Standard deviation(S.DEV).
Can store and perform statistical calculations15A measurement value.
There are two measurement methods: continuous measurement method(CONTINUE)And single measurement method(SINGLE).
It has an automatic shutdown function.
Delete function: Delete single suspicious data that appears during measurement, or delete all data in the storage area for new measurement.
There is a buzzing sound during the operation process.
There is an undervoltage indication function.
There is an error prompt function.
TT220 Coating Thickness GaugeMain technical indicators:
Measurement principle: magnetic method
measuring range: one1250μm
Measurement accuracy:±3%H+1μm(Zero point calibration)
±[(13)%H+1] μm(Two point calibration)
TT220 Coating Thickness GaugeStandard configuration:
host
Calibration test block
Standard test piece
Charger
Random file


Extra large range coating thickness gauge (30mm)
The MC-3000S FN30 coating thickness gauge can measure the thickness of coatings quickly, without damage, and with precision. It can be used in both laboratories and engineering sites. By using different probes, various measurement needs can also be met. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields. This instrument meets the following standards: GB/T 4956-1985 Measurement of thickness of non-magnetic coatings on magnetic metal substrates Magnetic methods GB/T 4957-1985 Measurement of thickness of non-conductive coatings on non-magnetic metal substrates Eddy current methods JB/T 8393-1996 Magnetic and eddy current coating thickness measuring instruments JJG 889-95 "Magnetic resistance thickness gauge" JJG 818-93 "Eddy current thickness gauge".
Functional features:
The eddy current thickness measurement method is adopted to non destructively measure the thickness of non-conductive coatings on metal substrates such as steel, iron, alloys, and aluminum copper
7 types of probes (F0.5, F1.2, F3, F5, F10, N1.2, F16, FN30) can be used. This configuration includes the FN30 probe
● Equipped with temperature compensation function: equipped with "phase-locked loop" technology
● Equipped with screen flipping function: can manually select to flip and display measurement data
Measurement speed: Customers can choose between single measurement and continuous measurement speeds according to different application scenarios
Display mode: 2.4-inch TFT high-definition color screen, 320 * 240 pixels, large digital display.
Three methods can be used to calibrate the instrument, and the basic calibration method can be used to correct the system error of the measuring head
● With storage function: can store over 10000 measurement points
● It has a deletion function: it can delete a suspicious data in the storage group, or delete all stored data for new measurements
● Set limit: Automatic alarm for measurement values outside the limit; And a histogram can be used to analyze a batch of measurement values
● Display language: Built in Chinese and English
● Measurement units: metric, imperial convertible
● Printing function: can be connected to a Bluetooth printer to print measurement data
● Equipped with wireless communication function: Bluetooth 2.0, capable of wireless communication with computers and printers
● Equipped with power undervoltage indication function
● There is a buzzing sound during the operation process to prompt
There are two shutdown modes available: manual shutdown mode and automatic shutdown mode
V-shaped groove: The user-friendly V-shaped groove structure facilitates the measurement of coatings on the outer surface of pipes of various sizes
● Large flat bottom: The specialized large flat bottom probe structure makes the instrument measurement more stable and has higher repeatability
Anti slip pad: The professionally designed anti slip pad, combined with the anti slip texture on the back of the chassis, ensures that customers are not easily fatigued even after long-term operation, reflecting the consistent concept of customer first
Function Introduction:
Simplified measurement mode, monitoring mode, statistical mode, * * * small value capture
Measurement principle: eddy current
Measurement range probe determines FN30 range: F 5~30mm N 3~30mm
Probe connection method MC-3000S split type wire connection (other probes cannot be replaced)
Temperature compensation equipped with * * * "phase-locked loop" technology
Built in Chinese and English languages
Display mode: 2.4-inch TFT high-definition color screen, 320 * 240 pixels, large digital display, supports flip display.
Customers can choose between single measurement and continuous measurement speeds based on different application scenarios
Data interface Bluetooth 2.0, capable of wireless communication with computers and printers
Storage options include manual and automatic storage, with a storage capacity of over 10000 readings.
Calibration methods include basic calibration, system calibration, and point calibration
A calendar can display time information and also make stored data traceable with time
Units in metric and imperial systems are convertible
Two AA batteries for power supply
Operating temperature and relative humidity: ≤ 90%; Temperature:- 10℃~+40℃
Host size 150mm (L) * 68mm (W) * 33mm (H)
Weight 220g (including battery)
Resolution (μ m) 0.1
Error ± (2-3%) H ± 1 Note: H is the thickness value of the measured coating
Display accuracy 0~100 μ m: 0.1μm; 100~999μm: 1μm; 1mm~9mm: 0.01mm; Above 10mm and 0.1mm
Base * * * small plane diameter 80mm
***Small substrate thickness 5mm


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!