Water temperature modeling machine
DESCRIPTION
Production Description:
Thermostat/Mold Temperature Controllers/There is no temperature control feature.
1Computer touch control, simple and easy to understand operation.
2Japanese imported microcomputer dual groupP.I.DTemperature control table,Touch sensitive internal storage,autotune,Less electricity35%the above
3Complete security protection and fault indication system.
4Advanced components for imported products,Long service life.
5Fast temperature rise and fall speed,Accurate and stable temperature.
6Unique and powerful heating design,Suitable for use in different temperature controlled locations,Significant energy-saving effect.
7Non induced steel integrated molding,Manage small donations,Cook evenly.
8Automatic exhaust function upon startup.
9Mold return water temperature detection table.
Application scope
Suitable for laser marking,Laser Engraving,laser cutting,Small injection molding machine and coating machine,Cooling of food and drug production equipment, etc
model |
YYM-003 |
YYM-006 |
YYM-009 |
YYM-012 |
YYM-018 |
YYM-024 |
YYM-009H |
YYM-012H |
YYM-018H |
YYM-024H |
||||
Heat transfer media |
oil |
|||||||||||||
temperature range |
℃ |
30~200 |
30~300 |
|||||||||||
HEATING CAPACITY |
Kw |
3 |
6 |
9 |
12 |
18 |
24 |
9 |
12 |
18 |
24 |
|||
power supply |
Volt |
3phase-380v-50HZ |
||||||||||||
pumping |
power |
Kw |
0.37 |
.037 |
.075 |
1.5 |
1.5 |
2.2 |
1.5 |
1.5 |
2.2 |
3 |
||
maximum flow |
l/min |
40 |
40 |
58 |
115 |
115 |
250 |
120 |
120 |
158 |
210 |
|||
Maximum pressure |
Ka/cm |
2.7 |
2.7 |
3.7 |
4.6 |
4.6 |
2.7 |
2.3 |
2.3 |
2.6 |
2.72.7 |
|||
Cooling method |
Indirect cooling |
|||||||||||||
Pipe diameter |
External pipe diameter |
lnch |
3/8” |
3*-/8” |
3/8”” |
1” |
1” |
1” |
1” |
1” |
1” |
1” |
||
entrance and exit |
quantity |
2*2 |
2*2 |
2*2 |
3*2 |
1*2 |
1*2 |
1*2 |
1*2 |
1*2 |
1*2 |
|||
But the diameter of the pipe |
lnch |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
|||
Mechanical dimensions
|
mm |
650 |
650 |
650 |
680 |
750 |
750 |
1150 |
1150 |
1200 |
1200 |
|||
300 |
300 |
300 |
350 |
400 |
400 |
500 |
500 |
500 |
500 |
|||||
550 |
550 |
580 |
600 |
650 |
650 |
1050 |
1050 |
1200 |
1200 |
|||||
Mechanical weight |
kg |
60 |
65 |
90 |
105 |
120 |
128 |
103 |
125 |
138 |
145 |
Compared to oil temperature control systems, water temperature heaters, ultra-high temperature water heaters, circulating temperature controllers, and mold temperature controllers have advantages in using water as a medium; Thermal transmission instructors have high efficiency, minimal pollution, and easy access to water resources, but their temperature control range is small, with a maximum of only98The temperature control range of the super boiling point water temperature machine developed by our company has reached180Degree, recently launched temperature control accuracy has reached0.1Degree, model (suitable for laser disc production)
)This provides a broader space for the application of water temperature machines
Ultra high temperature water temperature machine180Characteristics: Water temperature heater, ultra-high temperature water temperature machine, with circulating temperature control machine, mold temperature machine
1. Computer touch mode control, separate electrical control operation is simple and easy to understand, (optional)
2. Temperature controlled watchmaking color in JapanOMRON、RKCMicrocomputer dual groupP.I.DControl control,Automatic calculation of triggered internal storage,Accurate and reliable,save electricity35%the above,
3. Improve safety protection and fault indication system
4. Adopting imported advanced components,JapanFUJI,OMROU, FranceschneiderGermanySIEMNS,TaiwanANLYclass
5. Functions such as sucking out the mold and returning oil, full negative pressure operation, etc. (optional)
6. Stainless steel integrated molding, small tube donation, uniform heating
7. Automatic exhaust function upon startup.
model |
YYM-003 |
YYM-006 |
YYM-009 |
YYM-012 |
YYM-018 |
YYM-024 |
YYM-003H |
YYM-006H |
YYM-019H |
YYM-012H |
|||
Heat transfer media |
water |
||||||||||||
temperature range |
Kw |
30~100 |
30~150 |
||||||||||
HEATING CAPACITY |
Volt |
3 |
6 |
9 |
12 |
18 |
24 |
3 |
6 |
9 |
12 |
||
power supply |
3Phase-380V-50HZ |
||||||||||||
pumping |
power |
Kw |
0.37 |
0.37 |
0.75 |
1.5 |
1.5 |
2.2 |
0.37 |
0.37 |
0.75 |
0.75 |
|
maximum flow |
l/min |
43 |
43 |
55 |
112 |
112 |
260 |
42 |
42 |
61 |
61 |
||
Maximum pressure |
Ka/cm |
2.7 |
2.8 |
3.7 |
4.6 |
4.6 |
2.7 |
3.9 |
3.9 |
5.7 |
5.7 |
||
Cooling method |
direct cooling |
Indirect cooling |
|||||||||||
Pipe diameter |
External pipe diameter |
lnch |
3/8” |
3/8” |
3/8” |
3/8” |
1” |
1” |
3/8” |
3/8” |
3/8” |
3/8” |
|
entrance and exit |
quantity |
2*2 |
2*2 |
2*2 |
3*2 |
1*2 |
1*2 |
2*2 |
2*2 |
2*2 |
3*2 |
||
Cooling pipe diameter |
lnch |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
1/2” |
||
Mechanical dimensions
|
mm |
650 |
650 |
650 |
680 |
750 |
750 |
650 |
650 |
700 |
700 |
||
300 |
300 |
300 |
350 |
400 |
400 |
300 |
300 |
330 |
330 |
||||
500 |
500 |
550 |
550 |
650 |
650 |
500 |
500 |
550 |
550 |
||||
Mechanical weight |
kg |
55 |
60 |
85 |
100 |
115 |
125 |
55 |
60 |
85 |
95 |