The measurement lower limit is as low as 1mg/m3, fully capable of meeting the technical requirements for ultra-low emission monitoring scenarios;
The system has a simple structure and high reliability;
All core modules and algorithms are independently developed;
Compact structure, convenient for transportation and installation;
It can achieve full calibration.
Application scenarios
Monitoring and process control of exhaust emissions from coal-fired power plants, waste to energy plants, cement plants, glass plants, lime plants, ceramic plants, sintering plants, coke ovens, desulfurization processes, denitrification processes, etc.
Can monitor SO2 in gases NOx、O2、 Parameters such as dust, temperature, pressure, flow rate, etc. can also be extended to HCl for specific occasions HF、CO、CO2、 Monitoring of humidity and other parameters. The measurement lower limit is as low as 1mg/m3, fully capable of meeting the technical requirements for ultra-low emission monitoring scenarios. The laser backscatter dust analyzer is suitable for applications such as high humidity flue gas, leaky chimneys, and ultra-low dust emissions.
Specification parameters
SO2, NO: 0~50~100ppm (lower range can be customized)
NO2:0~100~200ppm (lower range can be customized)
O2 : 0-25%, humidity: 0-40%
Dust: 0~20mg/m3, 0~50mg/m3
Flow rate: 0-40m/s (customizable)
Temperature: 0-300 ℃ (customizable)
Pressure:- 10kPa~+10kPa (customizable)
Dimensions: 860mm × 650mm × 1800mm
Heat tracing temperature: 120 ℃~180 ℃
Protection level: Cabinet IP42, other IP65
Power supply: 220VAC, 5000W
Working temperature:- 20℃~+50℃
Working humidity: 0-95% RH (non condensing)
Compressed air requirements: (0.4~0.8)MPa,0.25m3/min,
Clean, oil-free, and waterless