Detailed introduction:
Instrument Introduction:The WS-108 model is a newly developed instrument for measuring and analyzing trace moisture. The instrument adopts a high-resolution color touch LCD display, which is convenient, intuitive, and easy to operate for human-machine dialogue. The instrument adopts a high-performance microprocessor with large data storage capacity, fast and stable operation, and excellent anti-interference performance, which has outstanding advantages of fast detection speed and high accuracy. The instrument has a fault self diagnosis function. After the test is completed, the measurement results will be displayed and printed. The instrument has the function of indicating the electrolytic current curve, making the testing status more intuitive; The instrument has a large data storage capacity and can store up to 250 data records; The instrument has a delay measurement function, which is very effective in testing samples with low moisture content; The instrument adopts touch stirring speed regulation; The formula for calculating moisture content includes multiple algorithms based on key parameters such as volume and weight; During the testing process, if it is necessary to modify the relevant parameters of the calculation formula, it can be done in a timely manner without affecting the moisture measurement results. The moisture content is calculated according to the newly modified parameters, which is convenient for users to use. This instrument adopts the Karl Fischer coulometric titration method, which can reliably determine trace moisture in liquid, gas, and solid samples. During testing, for solids that are insoluble in reagents and substances that are prone to contaminating electrodes and reagent reactions, corresponding solid, gas, and liquid samplers can be used for indirect measurement. It is an efficient and fully automatic analytical instrument. Widely used in industries such as power, petroleum, chemical, pharmaceutical, railway, environmental protection, scientific research institutions, etc.
Main technical parameters
Titration method:coulometric titration(coulometric analysis)
measure calm Fan Surrounding:2ug~100mg(Typical value)10ug~100ug)0.0001-100%water
quick Min Threshold:0.1ug
accurate true Degree: AccurateConversion from 2ug to 1mg ± 3ug and above 1mg to 0.3% (excluding injection errors)
try appearance class Type: Solid, liquid, and gas states
apparent show square Formula: 5.7Inch color high-definition touch display data storage:250Test record
form state finger Show: Electrolytic current curve and text display stir stir and mix transfer Speed: Touch panel speed control
sun designated time time Between: Ten years of normal operation real-time time after power failure
electricity Source:AC 220V±10V、50Hz±2.5HzPower:50VA
Environmental temperature for use: 5~35℃ usage environment humidity:≤85%