WP-R301C Blue Screen Paperless Recorder
WP-R301C 16 channel universal input blue screen paperless recorder, can input various signals such as standard current, standard voltage, frequency, m
Product details

WP-R301C 16 channel universal input blue screen paperless recorder, can input various signals such as standard current, standard voltage, frequency, millivolts, thermocouple, thermal resistance, etc.


It has sensor isolation distribution output, relay alarm output, transmission output, flow accumulation calculation, temperature and pressure compensation, cumulative report, historical data transfer, printing, and remote communication functions.


Features

• System

1. Adopting the latest large-scale integrated circuits and carefully designed components from internationally renowned factories.
2. High speed and high-performance 32-bit ARM microprocessor, with a screen response time of less than 0.2 seconds, capable of detecting, recording, displaying, and alerting 16 signals simultaneously.
3.5.6 inch 320 * 234 dot matrix TFT high brightness color graphic LCD display, LED backlight, clear picture, wide viewing angle.
4. Fully isolated universal input, capable of inputting multiple signals without the need for jumpers, can be configured through software.
5. The new switch power supply operates normally within the range of 85VAC~265VAC.
6. Integrated hardware real-time clock, which can run accurately even in the event of power failure.
7. Provide 24VDC isolated power distribution for the transmitter.
8. The all aluminum sealed shell and internal shielding plate ensure the normal operation of the instrument in harsh environments.
9. Large capacity FLASH flash memory chips store historical data and never lose data in case of power failure.
10.12 relay alarm output.
• Signal 1. Various standard signals can be input: standard current, standard voltage, frequency, millivolts, thermistor, thermocouple.
2. The full range accuracy of the signal is ± 0.5%.
3. Optoelectronic devices are used between channels for complete isolation.
4. Provide standard 4-20mA transmission output.
• Software 1. The software password lock ensures user configuration security.
2. Chinese menu configuration, which can be freely configured and display engineering tag numbers and engineering units.
3. The quantity display value reaches 4 and a half digits, and the display range is -9999~19999. It also supports vacuum degree calculation and Scientific notation display.
4. Simultaneously indicate the lower limit, lower limit, upper limit, and upper limit alarms of each channel, and record and display the latest 187 alarm messages.
5. Each channel supports traffic accumulation function, providing various report formats such as hourly reports, 8-hour shift reports, 12 hour shift reports, daily and monthly reports, etc.
6. Up to 4 sets of temperature and pressure compensation, supporting compensation calculations for flow devices such as orifice plates and vortex streets, as well as compensation media such as steam, water, and general gases.
7. The curve display mode can choose between horizontal or vertical curves.
8. Built in GB2312 second level Chinese character library (6500 Chinese characters).
9. The powerful T6 input method is easy to operate. Support input of Chinese Pinyin, numbers, English, special symbols, subscripts and other characters, using international standard encoding to solve the input problem of special units and Chinese character numbers.
• Communication

1. Standard serial communication interfaces: RS485 and RS232C.

2. Support standard Modbus RTU communication protocol, providing multiple data types such as percentage, engineering quantity, cumulative quantity, etc. In addition to supporting our company's upper computer management software, it also supports iFix, Kingview MCGS、 General professional configuration software such as force control does not require dedicated drivers.
3. Use USB 2.0 interface to transfer and backup historical data, supporting up to 2GB USB flash drive.
4. Supports FAT32 file system, Windows can automatically recognize backup data files without format conversion.
5. External micro printer can manually print data and curves, and automatically print real-time data at regular intervals to meet the needs of users for on-site printing.
display

• Construction

Installation method: Embedded instrument panel installation (vertical instrument panel), allowing for a maximum tilt of 30 degrees backwards and horizontal installation on both sides.

Instrument panel thickness: 2-26mm

Dimensions: 144 (W) * 144 (H) * 220 (D) mm

Weight: 4kg


• Input section

Input points: 1-12 channels, 16 channels

Measurement cycle: 1 second

Type of input:



• Display section

Display: 5.6-inch TFT color LCD (320 * 234 dots)

Display color: Blue/White

Channel identifier: 5 Chinese characters or 10 letters (digits)

Channel unit: 3 Chinese characters or 7 letters (numbers)

Status display: Display screen name, board status, alarm status, USB device flag, loop display flag

Display screen: Measurement data display (overview, numerical display, bar chart display, curve display), historical curve display, information display (alarm information, cumulative report), functional screen (data backup, printing)

Overview display: Display data and alarm status of all measurement channels

Update rate: 1 second

Curve display: can be selected vertically or horizontally

Historical curve: reproducible data stored in memory

Can be enlarged by 1/2/4/8/16/32 times

Alarm information: A total of 15 records are displayed


• Temperature and pressure compensation function

Measurement devices: orifice plate, vortex street (current type), vortex street (frequency type)

Measurement medium: steam, water, general gas

Steam temperature: 0-600 ℃

Steam pressure: 0.1-22MPa

Steam state: automatically determines saturated steam and superheated steam

Water temperature: 0-150 ℃

Water pressure: 0.6MPa, 1.6MPa

Gas compression coefficient: Air, oxygen, nitrogen can be automatically queried,

A constant can be set for general gases.

Vortex coefficient: 0.00000~999999


• Storage function

External storage
Media: USB drive
Format: FAT32
Method: Document recording
Capacity: Maximum 2G

Internal storage

Media: Flash Memory

Format: Binary Save

Method: Continuous recording

Capacity: Channel 1-12
Record Interval storage time
1 second 3 days

2 seconds

6 days

5 seconds

15 Days

10 seconds

30 days

15 seconds

45 days

30 seconds

90 days

1 point

180 days

2 points

360 days

4 points

720 days

16 channels

Record Interval

storage time

1 second

40 hours

2 seconds

3 days

5 seconds

8 days

10 seconds

16 days

15 seconds

24 days

30 seconds

48 days

1 point

96 days

2 points

192 days
4 points 384 days

• Alarm function

Alarm function

Number of settings: Each channel can set up to 4 alarms.

Alarm types: upper limit alarm, upper limit alarm, lower limit alarm, lower limit alarm

Delay alarm: It can be set in the parameter settings, and all alarms use the same setting.

Setting range: 0-10 seconds.

Display: When an alarm occurs, the measurement data display screen shows the alarm status.

Regarding the clock

Clock: Hardware clock, keeps running when powered off.

Operating range: 2001 to 2099

Clock accuracy: ± 10ppm (0-50 ℃), excluding delay errors caused by turning on the power (less than 1 second).


• Power supply section

Rated voltage: 220VAC

Power supply voltage range: 85VAC~265VAC

Rated frequency: 50Hz

Starting current: maximum 7.5A

Power consumption: up to 30W (including optional features)

Normal operating conditions

Power supply voltage: 220VAC

Power frequency: 50Hz

Environmental temperature: 0-50 ℃

Environmental humidity: 0% to 85% (non condensing)

Preheating time: 30 minutes after turning on the power

Installation location: Indoor

• Additional specifications


Alarm output relay

Output points:

Channels 1 to 12: 0 to 12 o'clock

Channels 13-16: 0-8 o'clock

Contact type: normally open contact

Contact capacity: 3A/250VAC


• Communication function

Media: RS-232 or RS-485

Protocol: Modbus RTU (Slave) Protocol

Communication speed: 1200/2400/4800/9600/19200/38400/57600


• Printing function

Printer: Panel Micro Printer

Print content: real-time data, historical data, cumulative reports

Printing methods: manual printing, timed printing


• Analog output

Signal type: 4-20mA

Number of output channels: 0-4 channels are optional.

Output method: Measure the transmission output of the channel.

Maximum load: 750 Ω


24VDC transmitter power output

Output points: 4 circuits

Output voltage: 24VDC

Rated output current: 65mADC (overcurrent protection action current: approximately 90mA)


• Frequency input power output

Output voltage: 12VDC, 24VDC

Output point count: Same as the selected frequency input count.

Maximum output current: 30mADC

USB interface

USB interface specifications: compliant with Rev2.0 standard, host functionality

Number of interfaces: 1 (front)

Connectable devices: USB storage (USB flash drive)


• Accumulation/reporting function

Accumulated points: Same as the number of input channels, each input channel can accumulate points

Cumulative range: 0 to 999999999

Report types: daily report, 8-hour shift report, 12 hour shift report, daily report+monthly report

Report length: report type duration
TIMES 16 days
8-hour shift report 128 days
12 hour shift report 192 days
Daily and Monthly Reports 1 year
Online inquiry