Beijing Stawo Technology Co., Ltd
Home>Products>VERSASTAR series desktop multi parameter water quality measuring instrument
VERSASTAR series desktop multi parameter water quality measuring instrument
The VERSA STAR desktop multi parameter pH/ISE (ion concentration)/conductivity/dissolved oxygen measuring instrument features a large, color LCD scree
Product details

VERSA STAR desktop multi parameter pH/ISE (ion concentration)/conductivity/dissolved oxygen measuring instrumentFeaturing a large-sized, color LCD screen, it can simultaneously display readings, channels, time, date, sample number, user number, and calibration information. The loading and unloading module is plug and play, without the need to shut down.

Product features:

  • 5 measurement modules can be freely combined
  • The operation interface has 6 languages to choose from, including Chinese and English
  • Temperature calibration and automatic temperature compensation can compensate for the influence of temperature on electrode slope, ensuring measurement accuracy and making measurement results more reliable
  • Can save 2000 sets of measurement data, in compliance with GLP standards
  • Use USB or RS232 ports to transfer data or update instrument software
  • Built in data analysis software to transfer stored data or display real-time readings
  • Can simultaneously connect two Orion Star mixers
  • The pH/temperature module can automatically recognize USA, NIST, DIN buffer solutions
  • The pH/ISE (ion concentration)/temperature module has all the characteristics of the pH/temperature module and can edit the calibration results of pH/ISE, optimize the calibration curve, and avoid repeated calibration
  • The pH/LogR module includes all the advantages of the pH module, as well as electrode diagnostic function, which eliminates the need for additional temperature probes during measurement
  • The conductivity/temperature module can choose conductivity TDS、 Built in seawater salinity curve for salinity and resistivity measurement modes
  • Dissolved oxygen/temperature module instrument can automatically recognize polarographic dissolved oxygen probe and RDO fluorescence dissolved oxygen probe

Technical parameters:
pH measuring range -2.000 – 20.000
resolution 0.1, 0.01, zero point zero zero one
relative accuracy ±0.001
calibrated point 5 more points
Calibration editing function have
mV/RmV measuring range ±2000.0mV
resolution 0.1
relative accuracy ± 0.1mV or ± 0.05% of the reading, whichever is greater
EH ORP mode have
ion concentration measuring range 0 - 19999
resolution Three more significant digits
relative accuracy ± 0.1mV or ± 0.05% of the reading, whichever is greater
unit Ppm, M, mg/L,%, ppb or no unit
calibrated point 5 more points
Calibration editing function have
Calibration function Timed endpoint, linear calibration, optional non-linear automatic blank, low concentration measurement stability
conductivity measuring range 0.001μS – 3000mS
resolution 0.001 μ S or four significant digits
relative accuracy 0.5% ± 1 digit of the reading
Reference Temperature 5. 10, 15, 20, 25 ℃
Temperature compensation type Linear (0-10.0%/℃), non-linear, pure water non-linear, USP pure water limit value
Range of electrical constants 0.001 – 199.9
calibrated point 5 more points
Calibration editing function have
resistivity measuring range 2Ω – 100MΩ
resolution 2Ω-cm
relative accuracy 0.5% ± 1 digit of the reading
salinity type Actual salinity or seawater salinity
range
  1. -80.0pt NaCl (relative); 0.01-42 ppt actual salinity
resolution 0.01
relative accuracy ±0.1
TDS range 0 – 200ppt
resolution 4 significant digits
relative accuracy 0.5% ± 1 digit of the reading
TDS factor range Linear 0.01-10.00, default 0.49
dissolved oxygen probe Type Spectral dissolved oxygen or RDO fluorescence dissolved oxygen probe
Spectral dissolved oxygen concentration measuring range 0 – 90mg/L
resolution 0.1, zero point zero one
relative accuracy ±0.2
Saturation% measuring range 0 – 600%
resolution 1, zero point one
relative accuracy ±2%
RDO fluorescence method for dissolved oxygen concentration measuring range 0 – 50mg/L
resolution 0.1, zero point zero one
relative accuracy ±0.1mg/L(0- 8 mg/L);
±0.2mg/L(8- 20 mg/L);
10% of the reading (20-50 mg/L);
Saturation% measuring range 0 – 500%
resolution 1, zero point one
relative accuracy ±2%
Automatic compensation range for atmospheric pressure 450.0 – 850.0 mmHg
Salinity correction coefficient When using conductivity modules and electricity simultaneously, automatic salinity compensation can be achieved, or manual compensation can be used; 0 – 45ppt
calibration type Saturated water air, saturated air water, Winkler titration, anaerobic water
temperature range -5-105 ℃ (RDO is 0-50 ℃)
resolution 0.1
relative accuracy ±0.1
Temperature calibration function Yes, 1 o'clock
Data Storage quantity 5000 pieces, compliant with GLP standards
RECORD Manual, automatic, timed (interval)
Record editing Single deletion, selective deletion in whole or in part
input PH electricity BNC, Reference electrical interface
Conductivity or ATC probe 8-pin mini DIN interface
dissolved oxygen probe 9-pin mini DIN interface
output RS232 interface, USB interface
power supply The power adapter 100-240V AC, optional
AA battery 4 sections, standard configuration
BATTERY LIFE >800 hours
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!