Click count: 181
Listing time: January 1, 2020
National Service Hotline:
I want to inquire about the priceproduct description
1、 Overview of liquid turbine flowmeter:
TM-LWGY turbine flowmeterIt is composed of a turbine flow sensor and a display head, and is one of the ideal flow meters for liquid flow measurement.It has the characteristics of simple structure, high precision, and easy installation, maintenance, and use.Widely used in petroleum, chemical, metallurgical, water supply, papermaking, environmental protection, food and other fields, suitable for measuring stainless steel in closed pipelines1Cr18Ni9Ti、2Cr13And corundumAl2O3Hard alloy is a liquid that does not corrode and has no impurities such as fibers or particles. If used in conjunction with display instruments with special functions, it can be used for automatic quantitative control, over limit alarm, and other purposes.
2、 Characteristics of liquid turbine flowmeter:
1The pressure loss is small, and the impeller has anti-corrosion function.
2Has high resistance to electromagnetic interference and vibration, reliable performance, and long working life.
3Adopting advanced ultra-low power single-chip microcomputer technology, the whole machine has strong functions, low power consumption, and superior performance. Intelligent flow display with non-linear accuracy compensation function. The accuracy of the correction formula is better than0.02%.
4The instrument coefficient can be set online by pressing the button and can be displayed on the screenLCDOn the screen,LCDThe screen is intuitive, clear, and highly reliable.
5The intelligent turbine flowmeter adoptsEEPROMProvide power-off protection for accumulated flow and instrument coefficients. Protection time greater than10Year.
3、 Working principle of liquid turbine flowmeter:
Liquid turbine flowmeterThe fluid flows through the sensor housing, and due to the angle between the blades of the impeller and the flow direction, the impulse of the fluid causes the blades to have a rotational torque. After overcoming the friction torque and fluid resistance, the blades rotate. After the torque is balanced, the speed is stable. Under certain conditions, the speed is proportional to the flow rate. Due to the magnetic conductivity of the blades, they are in the magnetic field of the signal detector (composed of permanent magnet and coil). The rotating blades cut the magnetic field lines and periodically change the magnetic flux of the coil, causing electrical pulse signals to be induced at both ends of the coil. This signal is amplified and shaped by the amplifier, forming a continuous rectangular pulse wave with a certain amplitude, which can be transmitted to the display instrument remotely to display the instantaneous flow rate and cumulative flow rate of the fluid.
4、 Technical performance of liquid turbine flowmeter:
1.Nominal diameter: (4~200)mmBasic parameters are shown in Table 1;
2.Medium temperature: (-20~80)℃ (-20~120)℃;
3.Environmental temperature: (-20~55)℃;
4.accurate true Degree:±0.2%、±0.5%、±1%;
5.Detector signal transmission line system: three wire voltage pulse (three core shielded cable);
6.Power supply: Voltage:12V±0.144V,electric current:≤10mA;
7.Output voltage amplitude: high level≥8V, low level≤0.8V;
8.Transmission distance: The distance from the sensor to the display instrument can reach500Rice;
9.On site display power supply:3VPowered by lithium batteries, it can be used continuously3Year);
10.Display mode: On site LCD displays 6-digit instantaneous flow and 8-bit cumulative flow;
11.On site display with signal output power supply:24V;4~20mATwo wire current output, long-distance transmission1000Rice.
5、 Selection Table for Liquid Turbine Flowmeters:
TM
|
LWGY□
|
□□□
|
□
|
□
|
□
|
Explanation
|
|||
class
type
|
LWGYA
|
Flow sensor, pulse output three wire system+ 12V power supply;
|
|||||||
LWGYB
|
On site display type 3V battery power supply;
|
||||||||
LWGYC
|
On site display with 4-20mA, two-wire current output+ 24V power supply;
|
||||||||
LWGYD
|
Transmitter; 4-20mA output current output+ 24V power supply;
|
||||||||
state-owned
call
open up or clear out by poking or jabbing
footpath
|
4
|
Normal flow range
m3/h
|
0.04~0.25
|
Expand traffic range
m3/h
|
0.04~0.4
|
||||
6
|
0.1~0.6
|
0.06~0.6
|
|||||||
10
|
0.2~1.2
|
0.15~1.5
|
|||||||
15
|
0.6~6
|
0.4~8
|
|||||||
20
|
0.8~8
|
0.45~9
|
|||||||
25
|
1~10
|
0.5~10
|
|||||||
32
|
1.5~15
|
0.75~15
|
|||||||
40
|
2~20
|
1~20
|
|||||||
50
|
4~40
|
2~40
|
|||||||
65
|
7~70
|
3.5~70
|
|||||||
80
|
10~100
|
5~100
|
|||||||
100
|
20~200
|
10~200
|
|||||||
125
|
25~250
|
12.5~250
|
|||||||
150
|
30~300
|
15~300
|
|||||||
200
|
80~800
|
40~800
|
|||||||
explosion-proof
|
Unmarked, non explosion proof type
|
||||||||
B
|
Explosion proof type
|
||||||||
accuracy class
|
A
|
Accuracy level 0.2
|
|||||||
B
|
Accuracy level 0.5
|
||||||||
C
|
Accuracy level 1.0
|
||||||||
Turbine type
|
A
|
Normal flow range
|
|||||||
B
|
Expand traffic range
|
||||||||
explain:
Sensors with diameters ranging from DN4 to DN40 are threaded connections, equipped with front and rear straight pipe sections and filters, with a maximum pressure of 6.3 Mpa.
Sensors with diameters ranging from DN50 to DN200 are connected via flanges, with a maximum pressure of 2.5Mpa.
DN15~DN40 pipe diameter can be equipped with front and rear straight pipe sections or flexible joints, and the materials are divided into carbon steel and stainless steel.
If flange connection is required for DN15~DN40 pipe diameter, please specify when ordering.
★ High voltage type and special requirements should be specified when ordering.
|
6、 Installation requirements for liquid turbine flowmeter:
Previous: Thermal gas mass flowmeter
Next article: Electromagnetic flowmeter (integrated)
Related products
news
- Analysis of the advantages and disadvantages of plug-in vortex flowmeter[2020-01-01]
- The setting of circuit parameters for measuring different media using vortex flowmeter[2020-01-01]
- Analysis of the influence of the stabilizing system of the regulating water flow standard device on the instrument coefficient of the vortex flowmeter[2020-01-01]
- Requirements for installation environment of vortex flowmeter[2020-01-01]
- Manufacturer of vortex flowmeter briefly describes the problems encountered during operation[2020-01-01]
- Analysis of the advantages of intelligent orifice flowmeter in practical measurement[2020-01-01]