Jiangsu Tianmei Measurement and Control Instrument Co., Ltd
Home>Products>Turbine flowmeter (flange connection)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    258-8 Huancheng West Road, Jinhu County Development Zone
Contact Now
Turbine flowmeter (flange connection)
Turbine flowmeter (flange connection) Click count: 181 Time of listing: 2020-01-01 National service hotline: I want to inquire Product description 1.
Product details
Turbine flowmeter (flange connection)

Click count: 181

Listing time: January 1, 2020

National Service Hotline:

I want to inquire about the price

product description

1、 Overview of liquid turbine flowmeter:
TM-LWGY turbine flowmeterIt is composed of a turbine flow sensor and a display head, and is one of the ideal flow meters for liquid flow measurement.It has the characteristics of simple structure, high precision, and easy installation, maintenance, and use.Widely used in petroleum, chemical, metallurgical, water supply, papermaking, environmental protection, food and other fields, suitable for measuring stainless steel in closed pipelines1Cr18Ni9Ti2Cr13And corundumAl2O3Hard alloy is a liquid that does not corrode and has no impurities such as fibers or particles. If used in conjunction with display instruments with special functions, it can be used for automatic quantitative control, over limit alarm, and other purposes.

2、 Characteristics of liquid turbine flowmeter:
1The pressure loss is small, and the impeller has anti-corrosion function.
2
Has high resistance to electromagnetic interference and vibration, reliable performance, and long working life.
3
Adopting advanced ultra-low power single-chip microcomputer technology, the whole machine has strong functions, low power consumption, and superior performance. Intelligent flow display with non-linear accuracy compensation function. The accuracy of the correction formula is better than0.02%.
4
The instrument coefficient can be set online by pressing the button and can be displayed on the screenLCDOn the screen,LCDThe screen is intuitive, clear, and highly reliable.
5
The intelligent turbine flowmeter adoptsEEPROMProvide power-off protection for accumulated flow and instrument coefficients. Protection time greater than10Year.

High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;
·Good repeatability, short-term repeatability can reach 0.05%~0.2%, precisely due to its good repeatability, such as regular calibration or online calibration can be obtained
High precision flow meters are preferred for trade settlement;
·Output pulse frequency signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;
·Can obtain high frequency signals (3-4kHz) with strong signal resolution;
·Wide range, with a medium to large caliber of up to 1:20 and a small caliber of 1:10;
·Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;
·Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;
·There are various types of specialized sensors that can be designed according to the specific needs of users, such as low-temperature, bidirectional, and downhole sensors
Type, sand mixing special type, etc;
·Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance.


3、 Working principle of liquid turbine flowmeter:
Liquid turbine flowmeterThe fluid flows through the sensor housing, and due to the angle between the blades of the impeller and the flow direction, the impulse of the fluid causes the blades to have a rotational torque. After overcoming the friction torque and fluid resistance, the blades rotate. After the torque is balanced, the speed is stable. Under certain conditions, the speed is proportional to the flow rate. Due to the magnetic conductivity of the blades, they are in the magnetic field of the signal detector (composed of permanent magnet and coil). The rotating blades cut the magnetic field lines and periodically change the magnetic flux of the coil, causing electrical pulse signals to be induced at both ends of the coil. This signal is amplified and shaped by the amplifier, forming a continuous rectangular pulse wave with a certain amplitude, which can be transmitted to the display instrument remotely to display the instantaneous flow rate and cumulative flow rate of the fluid.

4、 Technical performance of liquid turbine flowmeter:
1.Nominal diameter: (4200mmBasic parameters are shown in Table 1;
2.Medium temperature: (-2080)℃ (-20120)℃;
3.Environmental temperature: (-2055)℃;
4.accurate true Degree:±0.2%±0.5%±1%;
5.Detector signal transmission line system: three wire voltage pulse (three core shielded cable);
6.Power supply: Voltage:12V±0.144V,electric current:≤10mA
7.Output voltage amplitude: high level≥8V, low level≤0.8V
8.Transmission distance: The distance from the sensor to the display instrument can reach500Rice;
9.On site display power supply:3VPowered by lithium batteries, it can be used continuously3Year);
10.Display mode: On site LCD displays 6-digit instantaneous flow and 8-bit cumulative flow;
11.On site display with signal output power supply:24V420mATwo wire current output, long-distance transmission1000Rice.

5、 Selection Table for Liquid Turbine Flowmeters:


TM
LWGY□
□□□
Explanation
class
type
LWGYA




Flow sensor, pulse output three wire system+ 12V power supply;
LWGYB




On site display type 3V battery power supply;
LWGYC




On site display with 4-20mA, two-wire current output+ 24V power supply;
LWGYD




Transmitter; 4-20mA output current output+ 24V power supply;
state-owned
call
open up or clear out by poking or jabbing
footpath
4



Normal flow range
m3/h
0.04~0.25
Expand traffic range
m3/h
0.040.4
6



0.1~0.6
0.060.6
10



0.2~1.2
0.151.5
15



0.6~6
0.48
20



0.8~8
0.459
25



1~10
0.510
32



1.5~15
0.7515
40



2~20
120
50



4~40
240
65



7~70
3.570
80



10~100
5100
100



20~200
10200
125



25~250
12.5250
150



30~300
15300
200



80~800
40800
explosion-proof



Unmarked, non explosion proof type
B


Explosion proof type
accuracy class
A

Accuracy level 0.2
B

Accuracy level 0.5
C

Accuracy level 1.0
Turbine type
A
Normal flow range
B
Expand traffic range
explain:
Sensors with diameters ranging from DN4 to DN40 are threaded connections, equipped with front and rear straight pipe sections and filters, with a maximum pressure of 6.3 Mpa.
Sensors with diameters ranging from DN50 to DN200 are connected via flanges, with a maximum pressure of 2.5Mpa.
DN15~DN40 pipe diameter can be equipped with front and rear straight pipe sections or flexible joints, and the materials are divided into carbon steel and stainless steel.
If flange connection is required for DN15~DN40 pipe diameter, please specify when ordering.
★ High voltage type and special requirements should be specified when ordering.



6、 Installation requirements for liquid turbine flowmeter:

1. The instrument installation adopts flange connection, threaded connection and clamping type;
2. The direction of liquid flow during installation should be consistent with the direction indicated by the arrow on the sensor housing, and the upstream straight pipe section should be ≥ 20dn, and the downstream straight pipe section should be ≥ 5dn (dn is the inner diameter of the pipeline).
3. Sensors should be kept away from external magnetic fields. If unavoidable, necessary measures should be taken;
4. In order to avoid affecting the normal transportation of liquids during maintenance, bypass pipelines should be installed outside the straight pipe sections at both ends of the sensor (as shown in Figure 4);
5. When installing sensors outdoors, please ensure that the amplifier plug is waterproofed;
6. The wiring of sensors and display instruments should be selected according to the power supply of the amplifier. Please refer to the relevant "User Manual" for details.


Previous: Thermal gas mass flowmeter

Next article: Electromagnetic flowmeter (integrated)

Related products

  • 便携式 精密数字压力计
    Portable precision digital pressure gauge
  • GNS-JYY-3过程信号校验仪
    GNS-JYY-3 Process Signal Verification Instrument
  • 热电偶、热电阻自动校验装置
    Automatic calibration device for thermocouple and thermistor
  • GNS-JYY-T热工仪表校验装置
    GNS-JYY-T Thermal Instrument Calibration Device

news

  • Analysis of the advantages and disadvantages of plug-in vortex flowmeter[2020-01-01]
  • The setting of circuit parameters for measuring different media using vortex flowmeter[2020-01-01]
  • Analysis of the influence of the stabilizing system of the regulating water flow standard device on the instrument coefficient of the vortex flowmeter[2020-01-01]
  • Requirements for installation environment of vortex flowmeter[2020-01-01]
  • Manufacturer of vortex flowmeter briefly describes the problems encountered during operation[2020-01-01]
  • Analysis of the advantages of intelligent orifice flowmeter in practical measurement[2020-01-01]
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!