Jinhu Borui Instrument Co., Ltd
Home>Products>Thermal gas mass flowmeter (pipe section type)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13915181617
  • Address
    Jinhu County Industrial Park, Jiangsu Province
Contact Now
Thermal gas mass flowmeter (pipe section type)
Product features: The thermal gas mass flowmeter has the advantages of small volume, easy installation, high degree of digitization, good seismic perf
Product details

1Thermal gas mass flow meteroverview

BR-RSL seriesThermal gas mass flow meterIt is an instrument that uses the principle of heat conduction to measure fluid flow rate. The instrument uses the constant temperature difference method to accurately measure gas mass flow rate. Thermal gas mass flow meters have the advantages of small volume, high degree of digitization, easy installation, and accurate measurement.

热式气体质量流量计图片
2、 Advantages of Thermal Gas Mass Flow Meter Technology
1. Traffic data model algorithm; Fuzzy theory control algorithm for temperature and humidity;
2. High performance intelligent microprocessors and analog-to-digital/analog-to-digital conversion chips;
3. Wide range ratio 1000:1; Large caliber, low flow rate, negligible pressure loss;
4. Directly measure mass flow without temperature and pressure compensation;
5. Low flow velocity measurement is very sensitive;
6. Convenient design and selection, easy installation and use;
7. Suitable for measuring the flow rate of various single or mixed gases.

3、 Product features of thermal gas mass flowmeter
1. Adopting highly stable platinum RTD sensor technology
2. Adopting the technology of 'balanced structure packaging' and self compensating for medium temperature
3. Algorithms that can achieve high linearity, high repeatability, and high accuracy
4. The range ratio is 1000:1 and can be expanded according to user requirements
5. It can achieve measurement of large pipe diameter and small flow rate. Small flow rates can be measured as low as zero, with a resolution of 0.001m/s
6. No movable parts, vibration effects can be ignored
7. The requirement for straight pipe sections is not higher than 1-2D
8. Unrelated to the temperature and pressure of the medium
9. High temperature algorithm, the medium temperature can reach+510 ℃,
10. Adopt high humidity algorithm to achieve high-precision measurement
11. Enter 12 point dynamic correction for traffic signals, with built-in 10 point correction
12. Online dynamic correction of current/voltage output
13. Not sensitive to small particles such as dust
14. Online uninterrupted loading and unloading, easy maintenance

4、 Application scenarios of thermal gas mass flowmeter
1. Public works - monitoring of electricity, gas, and water treatment
Gas in pipelines; Universal system; Biogas; Gas; natural gas; liquid gas; Preheating air for boiler
2. Oil and gas industry
Energy exchange; Gas recovery from filling wells; Gas metering; Gas quality analysis; Leakage test; Natural gas measurement; Monitoring of Torch Gas
3. Power industry
Gas measurement during gas distribution in fuel systems; Measurement of various gases in boilers and auxiliary systems; Gas measurement in gas furnaces; Hydrogen measurement; Measurement of primary and secondary air in power plant blast furnaces
4. Chemical industry
Smoke circulation monitoring; Gas flow measurement in sampling system; Gas flow measurement of induced draft fan; Measurement of ammonia gas in fertilizer plants; Measurement of various gas flow rates in battery factories
5. Metallurgical industry
Gas filling measurement in steel plants; Measurement of blast furnace gas in ironworks; Measurement of coke oven gas in coking plants; Measurement and control of heating furnace gas (blast furnace gas, coking gas, natural gas, etc.) in steel rolling mills; Control of gases such as hydrogen, oxygen, and nitrogen in heat treatment quenching furnaces, etc
6. Pulp and paper industry
Measurement of gases in wastewater treatment systems; Smoke flow monitoring; Boiler recovers secondary/tertiary air; Measurement of gas and air supply for boilers
7. Food and pharmaceutical industry
The addition of fresh air during processing operations; CO2 treatment in breweries; The flow rate of hot air in the bottle sterilizer; Measurement of gas flow rate during thermal oxidation process; Ventilation system; Boiler inlet, exhaust gas, process control
8. Environmental Protection
Gas measurement during biogas utilization process; Measurement of chlorine gas during chlorine treatment process; Gas measurement in aeration tanks during sewage treatment process; Monitoring the emissions of SO2 and NOX in the exhaust of chimney and flue gas
9. Other industries
Factory compressed air measurement; Coal powder combustion process with powder/gas ratio control fuel; Control of Hot Gas Flow from Vertical Grinding Mill in Cement Industry

5Thermal gas mass flow meterTechnical Parameter

6、 Measurement range of thermal gas mass flowmeter


Note: When DN<20mm, please consult our company for sensor size

Pipe segment sensor size table (flange connection)


inside diameter
(mm)DN

weight
(Kg)

installation length
(mm)L

Flange size (mm)

Rated pressure
(MPa)

D

D0

N×A

20

6.2

280

105

75

4×14

1.0

25

6.6

280

115

85

4×14

32

7.2

280

140

100

4×18

40

8.2

280

150

110

4×18

50

9.6

280

165

125

4×18

65

10.8

280

185

145

4×18

80

13.1

280

200

160

8×18

100

16.5

280

220

180

8×18

125

19.6

290

250

210

8×18

150

29.8

310

285

240

8×22

200

40

340

340

295

8×22

250

56

370

395

350

12×22

300

66

410

455

400

12×22

350

70

440

505

460

16×22

400

75

480

565

515

16×26

450

90

510

615

565

20×26

500

105

550

670

620

20×26

600

162

620

780

725

20×30

700

180

690

860

810

24×26

0.6

800

240

750

975

920

24×30

1000

390

890

1175

1120

28×30

1200

650

1030

1405

1340

32×33

1400

850

1160

1630

1560

36×36

1600

1150

1290

1830

1760

40×36

1800

1500

1430

2045

1970

44×39

2000

1890

1560

2265

2180

48×42

Note: The table only provides a rated pressure of 1.0Mpa. Please consult our company if it exceeds 1.0Mpa
7Thermal gas mass flow metermodel selection

BR-RSL

Thermal gas mass flow meter

Highway diameter

-XX

100 represents DN100


Installation form

G

Pipeline type

C

plug-in

1

threaded

2

Flange connection


nominal pressure

A

0~0.6MPA

B

0~1.0MPA

C

0~1.6MPA

D

0~2.5MPA

E

0~4.0MPA

F

0~6.4MPA

G

0~10MPA

H

0~16MPA


process conditions

0

ordinary

1

antisepsis

2

explosion-proof

3

high temperature


Input signal

A

no-output

B

4~20MA

C

RS485 MODBUS

power supply

1

220V AC

2

24V DC

8Price of Thermal Gas Mass Flow Meter

Due to different customer requirements for product specifications and technical indicators on site, prices may also vary. For accurate prices, please contact online customer service to verify the parameters and provide them.

Assembly of Thermal Gas Mass Flow Meter

thermal typegasqualityFlow meter head


thermal typegasqualityFlow meter calibration

thermal typegasqualityFlow meter (pipe section type, old model)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code