VIP member
Product details
MODEL TES-1315/1316
- High precision, K.J.E.T.R.S.N. multiple types of test rods
- T1/T2 dual display function (1316)
- 4200 pieces of memory data
- HI/LO alarm device.
- Maximum/minimum value (including time), maximum minus minimum value, average value, read value locking function
- Celsius, Fahrenheit, and absolute temperature switching function.
- Back light device.
Specification TES-1315/1316
measuring range | K - Type : -150.0℃ to +1370.0℃ (-200.0℉ to +1999.9℉) |
J - Type : -150.0℃ to +1090.0℃ (-200.0℉ to +1994.0℉) | |
T - Type : -150.0℃ to +400.0℃ (-200.0℉ to +752.0℉) | |
E - Type : -150.0℃ to +870.0℃ (-200.0℉ to +1598.0℉) | |
R - Type : 2.0℃ to +1767.0℃ (+35℉ to +1999.9℉) | |
S - Type : 2.0℃ to +1767.0℃ (+35℉ to +1999.9℉) | |
N - Type : -150.0℃ to +1300.0℃ (-200.0℉ to +1999.9℉) | |
resolution | K. J, E, T, and N types: 0.1 ℃/℉/K R and S types: 1.0 ℃/℉/K (0.1 ℃/℉/K for reference only) |
Error value (ITS-90) | K, J, E, T, N : ± [Read value 0.05%+0.5 ℃ (0.9 ℉)] Below -100 ℃ (-148 ℉): K, J, E, N : Add reading value 0.15% T : Add reading value of 0.45% R, S : ±[0.05% + 2℃ (4℉) ] |
temperature coefficient | Reading value: 0.01%+0.03 ℃ (0.5% ℉)+18 ℃~28 ℃ (+64 ℉~+82 ℉) [LCD range: below -100 ℃ (-148 ℉): K, J, E, N : Read value+0.04% T : Read value 0.08%] |
Maximum differential input voltage | 1V (difference in maximum voltage values between T1 and T2) |
input protection | 30V (any type of connector) |
Sampling rate | Once per second |
Operating/Storage Environmental Conditions | 0℃ ~ 40℃< 80% RH -10℃ ~ 60℃< 70 RH |
power supply | 6 AAA specification batteries |
BATTERY LIFE | About 200 hours. (Excluding backlight and buzzer) |
size | 152 (length) x 72 (width) x 37 (height) mm |
weight | Approximately 235 grams |
attachment | 1. Instruction manual and battery 2. Install software, RS232 cable, 9-to-25 RS232 connector |
Online inquiry