1、 Instrument Introduction
The TN-1 total nitrogen detector is a total nitrogen detector developed and designed by our company in accordance with the national standard "HJ 636-2012 Determination of Total Nitrogen in Water Quality - Alkaline Potassium Persulfate Digestion UV spectrophotometry" and industry requirements. This total nitrogen detector has PID automatic adjustment technology and functions such as curve self calibration and automatic zero adjustment, enhancing the accuracy and stability of the instrument; Widely used for total nitrogen detection in various industries such as laboratories, sewage treatment plants, universities, environmental monitoring departments, and research institutions.
2、 Main features
1. The measurement system adopts advanced optical systems and cold light sources, with high measurement accuracy, small drift, and good stability;
2. Adopting a 13:7 series high brightness large screen LCD display, with a Chinese operating system for easy operation;
3. The digestion system is independent of the measurement system and does not interfere with each other;
4. The digestion system adopts PID regulation technology, which has high temperature control performance, good stability, and saves energy consumption;
5. The instrument has an automatic calibration function, which can automatically adjust the calibration curve and improve measurement accuracy;
6. The use of spectrophotometry combined with specialized reagents greatly reduces operation time and workload;
7. Built in large capacity storage space, capable of storing 100 curves and 30000 measurement results;
8. The instrument comes with a computer connection interface, which can upload experimental data or connect to a printer to print data;
9. Optional external thermal printer for printing experimental data;
10. The instrument is equipped with dedicated data recording and processing software, which facilitates the storage, processing, and analysis of experimental data;
3、 Technical parameters
1. Determination method: Alkaline potassium persulfate digestion UV spectrophotometry
2. Measurement range: 0.001-100mg/L (segmented measurement, expandable)
3. Measurement error: ≤ ±5 %
4. Range of photometric measurement: 0-2A
5. Wavelength accuracy: ± 1 nm;
6. Linear photometric measurement: ± 0.002 A;
7. Repeatability of photometric measurement: ± 0.005 A;
8. Accuracy of photometric measurement: ± 0.005 A;
9. Dissolution temperature and time: 120 ± 1 ℃; 30min
10. Measurement time: Dissolve 9/12/25 water samples simultaneously within 30 minutes;
11. Temperature indication error: < ±1.5℃;
12. Uniformity of temperature field: ≤ 1.5℃;
13. Error in digestion time indication: ≤ ±3%;
14. Curve parameters: 100 measurement curve parameters can be set;
15. Record storage: capable of storing 30000 measurement results;
16. Printing: Portable printer, directly printing measurement results (optional);
17. Environmental temperature: (5~40) ℃; Environmental humidity: relative humidity<85% (no condensation);
18. Working power supply: AC220V ± 10%/50Hz; DC power supply can work continuously for 50 hours.
4、 Product configuration
Serial number |
name |
quantity |
Serial number |
name |
quantity |
1 |
host |
1 unit |
9 |
power cord |
2 pieces |
2 |
Dissolver (standard configuration)12Hole) |
1 unit |
10 |
data line |
1 piece |
3 |
Sealed digestion tube |
12 pieces |
11 |
Data processing software |
1 set |
4 |
Dissolve the protective cover |
1 pair |
12 |
certificate |
1 copy |
5 |
test tube rack |
1 set |
13 |
warranty card |
1 copy |
6 |
Colorimetric dish rack |
1 set |
14 |
instructions |
1 copy |
7 |
Colorimetric dish |
1 set |
15 |
||
8 |
Total nitrogen reagent |
1 set |
16 |