Core parameters of Swiss Wantong 899 Coulombic Moisture Analyzer

  • Minimum feed rate
    0/0
  • measurement accuracy
    0.3%
  • measurement resolution
    3ug
  • measuring range
    10μg~200mg
  • Instrument type
    Coulombic Karl Fischer moisture analyzer

The first product of Swiss WantongPortable Coulombic Moisture AnalyzerNow you can conduct moisture testing at any location you need!

  • Independent power supply, testing location no longer limited

  • Automatically detect samples and start moisture measurement automatically

  • Can be used in conjunction with a Karl Fischer furnace for difficult sample moisture determination

899 Coulombic Moisture AnalyzerThe rechargeable power box provides independent power supply, and a single charge can ensure the continuous and stable operation of the instrument for several hours.

  • Direct on-site sampling for more timely results

  • Direct on-site sampling and measurement result in more accurate and reliable results

  • No need to bring samples back to the laboratory, more convenient and efficient

Automatically sense the sample and start moisture measurement
899 Coulombic Moisture AnalyzerIt can thoughtfully "automatically sense samples", and once the sample enters the titration cell, it will immediately start measuring automatically.
Flexible upgrade, compatible with 860 and 885 Karl Fischer sample heating processors
After being used in conjunction with a Karl Fischer oven, the moisture in the sample is heated and separated, transported to a titration cell via a dry carrier gas, and then measured for moisture in the titration cell.


Characteristics of Karl Fischer Furnace:
Independent sealed sample bottle, suitable for direct sampling and sealing on site, without the need for sample transfer during measurement, resulting in more accurate results.
The headspace heating method has a small dead volume and minimal sample contamination.
860 type heating chamber and sample bottle volume are optional, allowing for different ranges of sample sizes.
Not all samples can be directly injected, and it is recommended to use it in conjunction with a Karl Fischer furnace when the following conditions exist.
The sample cannot be completely dissolved (plastic particles, polyester chips, artificial bones...)
Side reactions occur between the sample and Karl Fischer reagent (lubricant additives, samples containing aldehydes and ketones...)
Slow release of sample moisture
Sample moisture can only be released at high temperatures
The sample will contaminate the titration cell (lubricating grease...)
899 Performance parameters of Coulomb moisture analyzer

measuring range Recommended 10 μ g~200mg, maximum measurement limit 1000 mg
Electrolysis speed 2240μg H2O/min
measurement accuracy ±3μg(H2O:10μg~1000μg)
±0.3%(H2O:1000μg)
Number of pre stored methods 3
Number of user-defined methods that can be saved 100
Operator/Expert Level Mode Switching have
Expand automatic sample heating processor have
Real time titration curve have
Induction sample automatically starts moisture titration have
Titration stand Built in magnetic stirring; Can be connected to one 801 or one 803 mixing station externally
External devices such as scales, keyboards, and other USB devices 1 USB port, RS-232/USB conversion box (optional component)
temperature sensor Pt1000
Power supply mode External power supply or power box power supply optional (optional)
Specification (W × H × D, excluding titration cup protective cover) 144×112×282mm


Compliant with standard methods
ASTM E1064-2008 Karl Fischer coulometric titration method for determining the moisture content of organic liquids
ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
ASTM D6304-2007 Karl Fischer coulometric titration method for determining water content in petroleum products, lubricants, and additives
ISO 15512 Determination of Water Content in Plastics
ISO 10337-1997 Determination of Moisture in Crude Oil Karl Fischer Coulombic Titration Method
GB/T 6283-2008 Determination of moisture content in chemical products Karl Fischer method
GB/T 11146-2009 Determination of Crude Oil Water Content Karl Fischer Coulombic Titration Method
GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use
GB/T 5074-1985 Method for determination of moisture content in coking products by microcoulometry
GB/T 6023-2008 Determination of Trace Water in Butadiene for Industrial Use Karl Fischer Coulombic Method
GB/T 7376-2008 Determination of Trace Moisture in Fluoroalkanes for Industrial Use Karl Fischer Method
GB/T 7600-1987 Determination of Moisture Content in Transformer Oil during Operation (Coulombic Method)
GB/T 18619.1-2002 Determination of Water Content in Natural Gas Karl Fischer Coulombic Method
GB/T 18826-2002 Industrial 1,1,1,2-tetrafluoroethane HFC-134a
SH/T 0246-1992 Determination of Water Content in Light Petroleum Products (Electricity Method)
SH/T 0255-1992 Method for determination of moisture content in additives and lubricating oils containing additives (electric method)