VIP member
Six function verification furnace C2250
Product Name: Six Function Calibration Furnace C2250 Product Model: Six Function Calibration Furnace C2250 Product Exhibitor: Shenzhen York Technology
Product details
C2250 Six Function Verification Slot
C2250 provides an additional wide operating range, easy to use, and convenient to carry. As one of the ISOCAL-6 series, C2250 can be used as a dry furnace, liquid tank, blackbody source for infrared thermometers, surface temperature sensor calibrator, and ITS-90 fixed point calibrator for several mK (0.001 ℃). C2250 has two models, Basic (Type B) and On site (Type S). The B-type comes with a sophisticated temperature controller that displays the set temperature and dry body temperature. The S-type has a built-in digital indicator that can be connected to an external temperature sensor, providing better accuracy and traceability. When using the dry body furnace function, we recommend choosing the on Site dry body calibration furnace and selecting the on-site precision temperature probe. It can be used as an external standard for upper level traceability and calibration to establish an on-site temperature calibration laboratory. The UK based company Assunt uses an external probe connected to the on-site indicator to compensate for temperature gradients and load errors. We recommend the option of embedded independent indicator (field type) and standard platinum resistance thermometer to make it a completely independent calibration laboratory.
Ordering reference
C2250 provides an additional wide operating range, easy to use, and convenient to carry. As one of the ISOCAL-6 series, C2250 can be used as a dry furnace, liquid tank, blackbody source for infrared thermometers, surface temperature sensor calibrator, and ITS-90 fixed point calibrator for several mK (0.001 ℃). C2250 has two models, Basic (Type B) and On site (Type S). The B-type comes with a sophisticated temperature controller that displays the set temperature and dry body temperature. The S-type has a built-in digital indicator that can be connected to an external temperature sensor, providing better accuracy and traceability. When using the dry body furnace function, we recommend choosing the on Site dry body calibration furnace and selecting the on-site precision temperature probe. It can be used as an external standard for upper level traceability and calibration to establish an on-site temperature calibration laboratory. The UK based company Assunt uses an external probe connected to the on-site indicator to compensate for temperature gradients and load errors. We recommend the option of embedded independent indicator (field type) and standard platinum resistance thermometer to make it a completely independent calibration laboratory.
![]() ![]() |
Indicator | C2250 type |
Temperature range: | 30℃ ~ +250℃ | |
Absolute stability exceeding 30 minutes | ||
1 Dry body verification furnace: | ±0.03℃ | |
2 Mixing liquid tank: | ±0.025℃ | |
3 Blackbody Furnace: | ±0.3℃ | |
Surface temperature sensor calibrator: | ±0.5℃ | |
5 1TS-90 fixed point equipment: | ±0.0005℃ | |
Cooling time | 250 ℃ to ambient temperature for 25 minutes | |
Heating time | Environmental temperature to 250 ℃ for 25 minutes | |
Verification capacity: | 35mm diameter, 160mm depth | |
uniformity: | ±0.018℃ | |
Display resolution | up to 99.99 0.01℃ 100 to 250 0.1℃ | |
Indicator unit: | ℃,℉, K | |
External dimensions: | 302mm(H)×176mm(W)×262mm(D) | |
Standard input casing |
Six holes: 1 × 9.5mm; 1×8.0mm; 2×6.4mm; 2 × 4.5mm all 157mm deep |
|
Weight: | 8kg |
Ordering reference
Fortunately, users do not need to purchase the entire verification package at once. For example, you can purchase a dry body calibration furnace first and add accessories according to your own needs in the future. Due to the replaceability of various attachments, ISOCAL-6 has greater flexibility
|
|||
option | function | model | |
1 | Dry body verification furnace | C2250B | |
2 | Mixing liquid tank | Basic type with temperature controller | |
3 | Mixing ice/sink | C2250S | |
4 | Black body furnace | On site type with temperature controller and indicator | |
5 | Surface thermometer calibration furnace | C2250SN | |
6 | ITS-90 fixed point equipment | On site type, equipped with temperature controller, indicator, NAMAS certificate and standard PT100 probe | |
Options
|
7 Carrying Boxes 8 standard probes 9 Sensors/thermometers for options 1 and 2 10 RS232 communication or RS422 communication |
Online inquiry