overview
Suitable for implementing time-division or tiered billing for residential users, it can be equipped with carrier network for meter reading and remote cost control according to customer needs;
main features
DDZY1778-ZThe model adopts high-precision MCU and high-precision circuit design, which has the characteristics of stable performance, rich functions, and strong anti-interference ability. It adopts a fully sealed structure and shell, which can meet the application of harsh high and low temperature alternation and humid environment, and has a longer service life;
major function
Ø It can measure voltage, current, and power, and can measure positive and negative active energy. It can be stored cumulatively for up to 12 months and has power direction recognition and indication functions;
Ø Optional zero line CT, capable of measuring zero line data and zero line energy metering function;
Ø It has the function of time division and multiple rate electricity metering, and can modify the time period rate parameters through parameter setting software;
Ø It has freezing and settlement functions, supporting up to 3 settlements within a month;
Ø Equipped with backlit LCD display, supporting rich status indicators and Chinese auxiliary information prompts;
Ø Supports RS-485 and infrared communication, with optional carrier communication methods, both supporting DL/T645-2007 and Q/GDW11778-2017 protocols;
Ø Having multiple event recording functions;
Ø Built in relay control, supports remote opening and closing function through 485 or carrier communication;
Ø After a power outage, the display can be awakened by pressing the button for meter reading;
Ø 485The default baud rate is 2400bps, which can be modified to 1200-9600 through parameter setting software;
Ø Voltage signal power supply, no need for auxiliary power supply;
performance parameter
project |
TECHNICAL INDEX |
Main technical standards |
GB/T17215.321-2008 |
reference voltage |
AC 220VResolution: 0.1V |
Working voltage range |
70%Un~120%Un |
Common current specifications |
Direct access type 5 (60) A; Resolution: 0.001A (specifications can be customized according to requirements) |
active power |
Resolution: 0.0001KW |
active electrical energy |
Accuracy levels: Active 0.5, 1, 2; Resolution: 0.01KWh |
Working power supply |
No need for external power supply (direct power supply) |
Load switch |
Built in 1-channel relay |
operation temperature |
-25℃~+60 ℃, maximum operating temperature:- 40℃~+70℃ |
Frequency range |
(50±2.5)Hz |
Clock Error |
23℃,≤ 0.5s/d;- 25℃~+60℃,≤ 1.0s/d |
Communication protocol |
DL/T645-2007, Q/GDW11778-2017 |
External dimensions |
Length x Width x Thickness: 160mm x 112mm x 58mm (without module): 160mm x 112mm x 71mm (with module) |
Product wiring diagram