The design of LCMS-8040 retains the ultra-high speed of LCMS-8030 while achieving higher sensitivity improvement. By combining Shimadzu's UFsweeperTM collision chamber technology, high-precision quadrupole performance, and high-voltage power supply technology, ultra fast MRM ion pair collection can be achieved, up to 555 MRMs/sec. In addition, the LCMS-8040 has a positive and negative polarity switching capability of up to 15msec. Through these fast performances, LCMS-8040 will improve the throughput of analysis.
Description:
By adopting innovative ion optical systems and collision cell technology, we have achievedHigh sensitivity of MRM and scanning measurement. LCMS-8040 expands the application areas of LC/MS.
characteristic:·Sensitivity
By adopting innovative ion optics systems and collision cell technology, the LCMS-8040 can provide higher sensitivity for multiple reaction monitoring (MRM). The multipole rod ion lens enhances focusing and reduces ion loss, resulting in a 5-fold increase in the signal-to-noise ratio (S/N) of Levofloxacin. These improvements can also enhance the sensitivity of scanning modes, thereby expanding the application areas of LC/MS.
·Improve ion optical system to enhance sensitivity
·Improve collision chamber, enhanceCID efficiency
· ultra fast
The design of LCMS-8040 retains the ultra-high speed of LCMS-8030 while achieving higher sensitivity improvement. By combining Shimadzu's UFsweeperTM collision chamber technology, high-precision quadrupole performance, and high-voltage power supply technology, ultra fast MRM ion pair collection can be achieved, up to 555 MRMs/sec. In addition, the LCMS-8040 has a positive and negative polarity switching capability of up to 15msec. Through these fast performances, LCMS-8040 will improve the throughput of analysis.
·Q1 full scan has higher sensitivity
·MS/MS acquisition method achieves higher sensitivity
·durability
·Yafik area detection under ultra high speed
·Ultra high reliability
ShimadzuThe optimization of MRM by LCMS system is based on a series of fast automatic flow injection analysis, which can be completed in just a few minutes. Multi component analysis can also be automatically optimized, freeing analysts from repetitive, monotonous, and time-consuming work. The optimized MRM conditions on LCMS-8030 can be transferred to LCMS-8040. The methods on both instruments can be shared. The LCMS-8030 is also simple and convenient in terms of operation, maintenance, cleaning, and replacement of ion source related components, just like the LCMS-8030.