Shimadzu High Performance Liquid Chromatography SystemProminence LC-20A
Networking - Providing Solutions for Analysts
Stable performance - meeting customer requirements for instruments
Automation - Stability wins the trust of customers
System Controller Prominence CBM-20A/20Alite
>> CBM-20A
>> CBM-20Alite
Infusion unit Prominence LC-20AD/20AT/20AB
>> LC-20AD
>> LC-20AT
>> LC-20AB
Gradient system of infusion unit
>> LC-20AB
>>LC-20AD/20AT High Voltage GE Specification
>>LC-20AD/20AT Low Voltage GE Specification
UV Visible Detector
SPD-20A/SPD-20AV
>>Prominence SPD-M20A PDA detector
SPD-M20A
Prominence SIL-20A/20AC automatic sampler
Injection method: full volume injection, variable injection volume
Sample rack switcher
>>Sample rack switcher C
Column temperature box Prominence CTO-20A/20AC
Temperature regulation method: forced air circulation type
characteristic:
Main parameters:
Connectable units: 4 more infusion units, 1 automatic sampler, 1 column temperature box, 2 more detectors, 1 fraction collector, and 2 more auxiliary controllers
Number of connection units: 8 (can be increased to 12)
Data buffering: Approximately every 24 hours for analysis (at a sampling rate of 500ms, limited to LCsolution use only)
Connectable units: 4 more infusion units, 1 automatic sampler (excluding SIL-10AF/10AP/10A), 1 column temperature box, 2 more detectors, and 2 more auxiliary controllers
Number of connection units: 5
Data buffering: Approximately every 24 hours for analysis (at a sampling rate of 500ms, limited to LCsolution use only)
Infusion method: Parallel double plunger
Piston capacity: 10 μ L
Large discharge pressure: 40MPa
Flow setting range: 0.0001mL/min-10.0000mL/min
Flow accuracy: within 1% or 2 μ L/min, whichever is greater
Flow accuracy: 0.06% RSD or 0.02minSD, within the larger value
Infusion method: Series double plunger
Piston capacity: Main pump head 47 μ L, auxiliary pump head 23 μ L
Large discharge pressure: 40MPa
Flow setting range: 0.001mL/min-10.000mL/min
Flow accuracy: within 2% or 2 μ L/min, whichever is greater
Flow accuracy: 0.06% RSD or 0.02minSD, within the larger value
Infusion method: Parallel double plunger (Type 2)
Piston capacity: 10 μ L
Large discharge pressure: 40MPa
Flow setting range: 0.0001mL/min-10.0000mL/min
Flow accuracy: within 1% or 2 μ L/min, whichever is greater
Flow accuracy: 0.06% RSD or 0.02minSD, within the larger value
Gradient method: high-pressure mixing
Number of mixed solvents: 2 liquids
Gradient method: high-pressure mixing
Number of mixed solvents: 2 or 3 liquids
Gradient method: low-pressure mixing
Number of mixed solvents: 4 more liquids
>>Prominence SPD-20A/20AV UV-VIS detector
Light source: SPD-20A D2 light, SPD-20AV D2 light, W light
Wavelength range: SPD-20A 190nm-700nm, SPD-20AV 190nm-900nm
Wavelength accuracy: below 1nm
Wavelength accuracy: below 0.1nm
Noise: ± 0.25 × 10-5AU
Drift: ± 0.5 × 10-4AU/h
Linear:>2.5AU
Function: Dual wavelength detection at 190nm-370nm or above, proportional chromatogram output, wavelength scanning, time program
Light source: D2 lamp, W lamp
Number of diode components: 512
Wavelength range: 190nm-800nm
Wavelength accuracy: below 1nm
Wavelength accuracy: below 0.1nm
Noise: ± 0.3 × 10-5AU
Drift: 0.5 × 10-3AU/h
Linear:>2.0AU
Function: Contour line output, spectral retrieval, large output
Injection volume setting range: 0.1 μ L-100 μ L (standard), 1 μ L-2000 μ L (optional)
Sample processing quantity:
175 (1mL sample bottle)
105 (1.5mL sample bottle) SIL-20AC 70 (1.5mL sample bottle)
50 (4mL sample bottle)
192 (96 hole MTP 2 pieces)
768 (384 hole MTP 2 pieces)
In addition to the above specifications, an additional 10 1.5mL sample bottles can be used
Injection volume accuracy: less than 1%
Injection volume accuracy: below 0.2% RSD
Cross contamination: typical value below 0.0025% (naphthalene, chlorhexidine)
Repeated injection times: 30/1 sample
Needle cleaning: set arbitrarily before and after injection
Sample cooler: SIL-20A without SIL-20AC module cooling and heating method, with moisture removal function at 4 ℃ -40 ℃
Applicable plates: 96 well MTP, 96 well DWP, 384 well MTP, 384 well DWP, 1.5mL sample bottles (54 pieces)
Number of board processing blocks: 12P
Sample cooler: module cooling and heating method, with moisture removal function at 4 ℃ -40 ℃
Cooling method: CTO-20A None, CTO-20AC Electronic Cooling
Temperature control accuracy: below 0.1 ℃ (typical value below 0.04 ℃)
Temperature control range: CTO-20A (room temperature+10) ℃ -85 ℃, CTO-20AC (room temperature -10) ℃ -85 ℃
Storage space: W220 × H365 × D95mm
Can accommodate instruments: 2 manual samplers, gradient mixers, 2 high-pressure flow path switching valves, etc
Timer program: Linear temperature program
Stability measures: solvent sensor, temperature fuse, upper limit temperature control