brief introductionBrief Introduction
The latest Measures for the Administration of License for Installation (Repair, Testing) of Electric Power Facilities will come into effect on October 11, 2020. The "Measures for the Administration of License for Installation (Repair, Testing) of Power Facilities" (Order No. 28 of the State Electricity Regulatory Commission) announced by the former State Electricity Regulatory Commission on December 18, 2009, are hereby abolished. Huatian Power provides a brief introduction to the new version of the construction equipment selection guide required for the second level power facility license for installation (repair, testing).
Obtaining a second level installation (repair, testing) license, one can engage in the installation, maintenance, or testing activities of power facilities with voltage levels below 330 kV.
To learn about the application materials and filling specifications for the installation, maintenance, and testing of power facility licenses, you can click on "Application Specifications" to browse.
Alternative names: Secondary Testing Instruments, Secondary Testing Equipment, Testing Instruments and Equipment, Secondary Testing Configuration Table, Secondary Testing Equipment, Secondary Testing Equipment Selection Table
configuration tableConfiguration Table
Test Level 2 Configuration Table
Serial Number | Name of machinery and equipment | unit | quantity | specifications | Specification and model |
one | High voltage generating equipment | ||||
1 | DC high voltage generator | cover | 1 | DC:250kV/5mA | ZGF-250kV/5mA |
2 | Power frequency withstand voltage test device | cover | 1 | AC:10kVA/100kV | GSB-10kVA/100kV |
cover | 1 | AC:5kVA/50kV | YDJ-5kVA/50kV | ||
3 | Complete set of equipment for frequency conversion series resonance test | cover | 1 | 2000kVA/400kV/5A 30~300Hz |
HTXZ-2000kVA/400kV |
4 | Induction voltage withstand test device | cover | 1 | 5kVA/360V 150Hz |
SBF-5kVA/500V |
two | Electrical measuring instruments | ||||
1 | High voltage dielectric loss tester | tower | 2 | 1. The accuracy of medium measurement is 1% 2. The capacitance accuracy is 0.5% 3. Anti interference frequency conversion |
HTJS-V |
2 | Loop resistance tester | tower | 2 | DC:≥100A | HTHL-100A |
3 | Transformer volt ampere characteristic tester | tower | 1 | 2200V/5A | HTFA-105 |
4 | Ground Resistance Tester | tower | 1 | Frequency difference method | HTDW-5A |
5 | Capacitance and inductance tester | tower | 1 | HTRG-H | 6 | Grounding continuity tester | tower | 1 | DC:1A | HTDT-10A |
7 | Transformer DC resistance tester | tower | 2 | DC:≥10A | HTZZ-10A |
8 | Transformer ratio tester | tower | 1 | Digital 0.5 level | HTBC-H |
9 | Transformer winding deformation tester | tower | 1 | Frequency response method | HTBX-H |
10 | Load tap changer tester | tower | 1 | I≧1A | HTBYC-3000 |
11 | Circuit breaker characteristic tester | tower | 2 | HTGK-III | |
12 | Zinc oxide lightning arrester resistive current tester | tower | 1 | HTYB-3H | |
13 | Three phase relay protection tester | tower | 2 | Two sets of three-phase voltage and current each | HT-1200 |
14 | Transmission line parameter tester | tower | 1 | Frequency difference method | HTXL-Y |
15 | Lightning strike counter calibrator | only | 1 | HTFZ-III | |
16 | insulation resistance tester | tower | 2 | DC:0~5000V 200G(Ω) Short circuit current ≥ 5mA |
GM-5kV |
three | Oil and gas testing instruments | ||||
1 | SF6 leak detector | tower | 1 | Sensitivity 1ppmv | XP-1A |
2 | SF6 gas micro water tester | tower | 1 | HTWS-V | |
3 | SF6 gas density calibrator | tower | 1 | Accuracy level 0.2 Pressure range 0~1.0Mpa |
HTMD-H |
4 | Insulation oil chromatograph | tower | 1 | HTYSP-H | |
5 | Insulation oil closed flash point tester | tower | 1 | HTYBS-H | |
6 | Insulation oil micro water meter | tower | 1 | PPM level | HTYWS-H |
7 | Insulation oleic acid value tester | tower | 1 | HTYSZ-H | |
8 | Insulation oil pH tester | tower | 1 | ||
9 | Automatic dielectric loss measuring instrument for insulating oil | tower | 1 | HTYJS-H | |
10 | Insulation oil dielectric strength tester | tower | 1 | HTJY-80B | |
four | Common instruments and meters | ||||
1 | Megger | only | 2 | DC:2500V | HT2671 |
2 | Megger | only | 2 | DC:500V | HT2670 |
3 | Digital dual clamp phase voltmeter | only | 2 | Measure current 1mA~5A | SMG2000B |
1. All national users who purchase our products enjoy free technical guidance, software upgrades, one-year warranty, and lifelong maintenance services.
2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448
qualifiedQualified
-
Those who have obtained the license for the installation (repair, testing) of second level testing power facilities can engage in testing activities for power facilities with voltage levels below 330kV. The applicant shall meet the following conditions:
-
1、 Net assets
-
Having net assets suitable for carrying out installation (repair, testing) of power facilities, with a proportion of no less than 15% of the total assets.
-
2、 Technical Manager, Safety Manager
-
Applicants for first to third level licenses must have at least 5 years of experience in the installation, maintenance, or testing management of power facilities that are suitable for the type of license being applied for, and hold intermediate or higher professional titles in power related fields; Those who apply for a first level license should have a senior professional title in the field of electricity.
-
3、 Professional technical and skilled personnel
-
For those applying for first to third level licenses, there shall be no less than 50, 30, and 15 professional and technical personnel in the field of electric power, among whom no less than 30, 15, and 5 have intermediate or above technical qualifications respectively; There shall be no less than 60, 30, and 20 professionals with specialized skills in the field of electricity, including no less than 30, 15, and 10 high-voltage electricians.
-
4、 For those applying for Level 1 to Level 3 licenses, in addition to meeting the above conditions, they should also have the following performance that is suitable for the category and level of the license being applied for:
-
1. For those applying for Level 1 to Level 3 installation permits, they should have a track record of engaging in the installation of transformer (distribution) and line facilities with voltage levels below 330 (220) kV, 110 (66) kV, and 35 kV and above, respectively, within the past three years, and the quality should be qualified; During this period, the highest annual engineering settlement income engaged in power facility installation business shall not be less than 200 million yuan, 100 million yuan, and 30 million yuan, respectively.
-
2. For those applying for Level 1 to Level 3 maintenance or testing licenses, they should have a track record of engaging in maintenance or testing activities for transformer (distribution) and line facilities with voltage levels below 330 (220) kV, 110 (66) kV, and 35 kV and above, respectively, in the past two years.
Product FeaturesProduct Characteristics






















Product videoProduct Video
Instrument AtlasInstrument Pictures
(Secondary testing instrument) High voltage generating equipment

DC high voltage generator

10kVA/100kV power frequency withstand voltage test device

5kVA/50kV power frequency withstand voltage test device

Complete set of equipment for frequency conversion series resonance test

Induction voltage withstand test device
(Secondary testing instrument) Electrical measuring instrument

High voltage dielectric loss tester

Loop resistance tester

Transformer volt ampere characteristic tester

Ground Resistance Tester

Capacitance and inductance tester

Grounding continuity tester

Transformer DC resistance tester

Transformer ratio tester

Transformer winding deformation tester

Load tap changer tester

Circuit breaker characteristic tester

Zinc oxide lightning arrester resistive current tester

Three phase relay protection tester

Transmission line parameter tester

Lightning strike counter calibrator

insulation resistance tester
(Secondary testing instrument) Oil and gas testing instrument

SF6 leak detector

SF6 gas micro water tester

SF6 gas density calibrator

Insulation oil chromatograph

Insulation oil closed flash point tester

Insulation oil micro water meter

Insulation oleic acid value tester

Automatic dielectric loss measuring instrument for insulating oil

Insulation oil dielectric strength tester
(Secondary testing equipment) Common instruments and meters

2500V megohmmeter

500V megohmmeter

Digital dual clamp phase voltmeter
product certificateProduct Certificate
Our company's products are strictly produced in accordance with international and national standards and industry regulations. They have passed the testing of national, provincial, and municipal power research institutes, measurement centers, and authoritative power departments, and have fully passed the ISO9001 international quality management system certification, the People's Republic of China manufacturing measuring instrument license, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, and GB/T45001-2020 occupational health and safety management system requirements.