Schmidt vortex flowmeter, with strong reliability and high accuracy, model: LUGB
LUGB Vortex Flow Meter Overview: The LUGB type vortex flow sensor is an ideal alternative to orifice flow meters The vortex flowmeter is a type of flo
Product details
LUGBswirl flowmeter

1 overview

The LUGB vortex flow sensor is an ideal alternative to orifice flow meters The vortex flowmeter is a type of flowmeter developed based on the Karman vortex street principle. Due to its unique advantages that cannot be achieved by other flowmeters, it has developed rapidly since the 1970s. According to relevant data, the proportion of vortex street flowmeters used in developed countries such as Japan, Europe, and America has increased significantly and has been widely used in various fields. It will play a dominant role in future flow meters
The LUGB vortex flow sensor is suitable for measuring the mass and volume flow rates of superheated steam, saturated steam, compressed air, and general gases, water, and liquids

2、 Technical performance

Summary Table of Standard Flow Range: Unit (m)3/h)

internet traffic

caliber

Liquid flow range

Gas flow range

Saturated steam flow range

Zui small traffic

Zui high traffic

Zui small traffic

Zui high traffic

Zui small traffic

Zui high traffic

DN25

0.9

14

8.3

110

13

1500

DN40

2.5

35

26

300

25

4400

DN50

3.3

55

36

480

40

6800

DN80

8.0

150

90

1300

100

19000

DN100

14

240

140

2000

160

29000

DN125

22

220

250

2500

350

35000

DN150

38

450

290

4100

350

66000

DN200

70

850

620

7500

620

118000

DN250

130

1300

700

12500

970

185000

DN300

180

2000

920

16500

1400

267000

3、 Workcharacteristic

The structure is simple and sturdy, with no movable parts, high reliability, and very reliable for long-term operation. Easy to install and very convenient to maintain. The detection sensor does not directly contact the measured medium, with stable performance and long lifespan. The output is a pulse signal proportional to the flow rate, with no zero drift and high accuracy. The measurement range is wide, and the range ratio can reach 1:10. Low pressure loss, low operating costs, and energy-saving significance. Within a certain Reynolds number range, the output signal frequency is not affected by changes in fluid physical properties and composition. The instrument coefficient is only related to the shape and size of the vortex generator, and there is no need for compensation when measuring fluid volume flow rate. After replacing accessories, there is generally no need to recalibrate the instrument coefficient. Widely applicable, the flow rates of steam, gas, and liquid can be measured. The verification period is two years.

LUGBThe application inner diameter range of the KTLUI type vortex flow sensor is 25-300mm (full tube type), and the application inner diameter range of the KTLUI type insertion vortex street flow sensor is 350-1200mm (insertion type). The full tube type measures liquid with an accuracy of 1%, steam and gas with an accuracy of 1.5%, the insertion type measures liquid with an accuracy of 2%, and steam and gas with an accuracy of 2.5%. The measured medium temperature is -20~150 ℃, -40~250 ℃,+100~350 ℃ (tube type only), and the output signal is a three wire voltage pulse, with a three wire 4-20mA and a two wire 4-20mA

4、 Basic structure and installation dimensions

The flowmeter consists of a body, a support column, and an amplifying display device. There are two ways to connect with pipelines, namely flange clamping and flange connection. Figure 2 shows the schematic diagram of flange clamping, Figure 3 shows the schematic diagram of flange connection, and Tables 1 and 2 provide relevant reference dimensions.

Figure 1 Flange connection method Figure 2 Flange clamping method

Table 1 Reference Dimensions for Flange Connections(mm)

DN

L

H

D1

D

bolt

number of elements

80

255

375

160

200

M16*70

8

100

280

410

190

235

M20*70

8

150

330

475

250

300

M24*80

8

200

380

535

310

360

M24*80

12

250

430

600

370

425

M27*90

12

300

480

660

430

485

M27*90

16

Table 2 Reference dimensions for flange mounting(mm)

DN

L1

L2

D

H

Equipped with seamless steel pipes

25

80

115

110

430

Ф32*3.5

40

106

145

150

475

Ф49*4.5

50

106

145

160

485

Ф60*5

80

106

155

205

520

Ф91*5.5

100

106

155

235

550

Ф111*5.5

125

140

190

250

570

Ф134*7

150

153

205

280

600

Ф163*6.5

200

173

230

340

660

Ф212*6

250

183

250

390

710

Ф262*6

300

185

250

450

760

Ф327*13.5