Shenzhen Kerei Technology Development Co., Ltd
Home>Products>SA6 Six Channel Spectrum Analyzer
SA6 Six Channel Spectrum Analyzer
Description: Simultaneously connect two three-axis flux gate sensors or accelerometers Provide time-domain and spectral analysis functions.
Product details

Tags: Flux Gate Gradienter, Flux Gate Magnetic Gradienter, Magnetic Field Gradienter, Magnetic Field Gradienter, Gradient Magnetometer

Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF501

fluxgate

handheld

1

0.5%

200μT

1nT

GF503

fluxgate

handheld

3

0.5%

200μT

1nT

GF601

fluxgate

handheld

1

0.5%

200μT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Gradiometer

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GR100

fluxgate

Gradiometer

3

0.1%

100μT

0.01nT

Data Acquisition System

model

Number of channels

function

FDU301

3

3Channel analyzer, connectable1Three axis flux gate sensor, providingDC,AC RMSand1KHzSpectrum analysis function

SA6

6

6Channel spectrum analyzer, can be connected simultaneously2A three-axis flux gate sensor or accelerometer, providing time-domain and spectral analysis functions

ASA1000

1-6000

High precision synchronous acquisition system, capable of connecting up to2000Three axis flux gate sensor with maximum synchronous acquisition speed40ksps/road

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F23

fluxgate

split type|Small size

3

<>

1500μT

±10V,single-ended

F31

fluxgate

Miniatur Probe

1

<>

200μT

±2.5V,finite difference

F33

fluxgate

Miniatur Probe

3

<>

200μT

±2.5V,finite difference

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

<>

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

AMS-1M3D

reluctance

Analog transmitter

3

1%

500μT

30Hz-1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------



SA6Six channel spectrum analyzer


sketch:

Six channel spectrum analyzerSA6Designed according to industrial standards, the structure is compact, reliable and practical. Six channel spectrum analyzerSA6synchronous acquisition6Channel data from magnetic field sensors, accelerometers, or acoustic sensors, and perform spectral analysis on the data.

Six channel spectrum analyzerSA6When used in conjunction with 3D magnetic flux gate sensors and 3D accelerometers, it can not onlyDCMeasure the static magnetic field in measurement mode, and it is possible toACMeasure AC magnetic field in measurement mode, with an AC response frequency of up to10kHzThree dimensional flux gate sensors can be selectedBartingtonBrand'sMag-03Mag-13andMag690orCOLIYBrand'sF901F902andF905Wait.



Upper computer software


The upper computer software provides many practical functions, includingXYZComponent value and vector value, maximum value, minimum value, relative value, set range, spectrum analysis, data storage, unit conversionAC/DCMeasurement mode switching, etc.






SA6 Six Channel Spectrum Analyzer - Technical Parameters


model

SA6

performance parameter

Number of input channels

6A channel. 2Group, each group3Input channels (data from 3D flux gate sensors, accelerometers, or acoustic sensors)

Input signal range

±10Vsingle-ended

Input frequency range

Magnetic Field

Accelerators and acoustic sensors

highest1kHz

DCto1kHz (DCcoupling)5Hzto1kHz (ACcoupling)

resolution

24High precision positioningA/Dconverter

Sampling rate

1-2000spsMaximum sampling interval1s

storage

Can collect up to700,000Sample data (depending on computer storage space)

Frequency domain display options

DCData sources andACdata source

Analog gain control

Can be selected on the software1Double2Double4Double8Double16Double32times

Spectrum range

Select sampling rate or maximum frequency through software

Sensor Input

single-ended(Unbalanced)

Requirements for 3D Flux Gate Sensors

Power Supply:±15Vor User Specified

Output signal:±10V/axle(Unbalanced, single ended reference0V)or User Specified

give an example:BartingtonBrand's 3D flux gate sensorMag-03Mag-13Mag690COLIYBrand'sF901F902F905class

Requirements for accelerometers

Power Supply:±15Vor User Specified

Signal output ratio:1V/gor10V/g

Acoustic sensor or any other sensor

Power Supply:±15Vor User Specified

Signal output ratio: User specified

Environmental requirements

operation temperature

-10to +50

storage temperature

-20to +70

Related humidity

0 to90%non-condensing

specifications

size

200mm W × 75mm H × 150mm L

weight

1.25kg

output interface

USB

Input Interface

2individual10Core waterproof connectors and6individualBNCinterface

Housing material

aluminum alloy

power interface

USB TYPE C 5V 1A

Digital Output

USB TYPE A




Optional Accessories


type

describe

Software-spectrum

SMART PC Software(Upper computer software)Spectrum analysis function

PS2005

Power adapter: Input100VAC- 240VAC

Output voltage:5VDC±5%

Rated output current:2A

power bank

Any commercially available power bank

Output voltage:5VDC±5%

Rated output current:>1A



Click to view other magnetic measurement devices


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!