Tags: Flux Gate Gradienter, Flux Gate Magnetic Gradienter, Magnetic Field Gradienter, Magnetic Field Gradienter, Gradient Magnetometer
Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF501 |
fluxgate |
handheld |
1 |
0.5% |
200μT |
1nT |
GF503 |
fluxgate |
handheld |
3 |
0.5% |
200μT |
1nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
200μT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Gradiometer | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GR100 |
fluxgate |
Gradiometer |
3 |
0.1% |
100μT |
0.01nT |
Data Acquisition System | ||||||
model |
Number of channels |
function |
||||
FDU301 |
3 |
3Channel analyzer, connectable1Three axis flux gate sensor, providingDC,AC RMSand1KHzSpectrum analysis function |
||||
SA6 |
6 |
6Channel spectrum analyzer, can be connected simultaneously2A three-axis flux gate sensor or accelerometer, providing time-domain and spectral analysis functions |
||||
ASA1000 |
1-6000 |
High precision synchronous acquisition system, capable of connecting up to2000Three axis flux gate sensor with maximum synchronous acquisition speed40ksps/road |
||||
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F23 |
fluxgate |
split type|Small size |
3 |
<> |
1500μT |
±10V,single-ended |
F31 |
fluxgate |
Miniatur Probe |
1 |
<> |
200μT |
±2.5V,finite difference |
F33 |
fluxgate |
Miniatur Probe |
3 |
<> |
200μT |
±2.5V,finite difference |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
<> |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
AMS-1M3D |
reluctance |
Analog transmitter |
3 |
1% |
500μT |
30Hz-1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
SA6Six channel spectrum analyzer
sketch:
Six channel spectrum analyzerSA6Designed according to industrial standards, the structure is compact, reliable and practical. Six channel spectrum analyzerSA6synchronous acquisition6Channel data from magnetic field sensors, accelerometers, or acoustic sensors, and perform spectral analysis on the data.
Six channel spectrum analyzerSA6When used in conjunction with 3D magnetic flux gate sensors and 3D accelerometers, it can not onlyDCMeasure the static magnetic field in measurement mode, and it is possible toACMeasure AC magnetic field in measurement mode, with an AC response frequency of up to10kHzThree dimensional flux gate sensors can be selectedBartingtonBrand'sMag-03、Mag-13andMag690orCOLIYBrand'sF901、F902andF905Wait.
Upper computer software
The upper computer software provides many practical functions, includingXYZComponent value and vector value, maximum value, minimum value, relative value, set range, spectrum analysis, data storage, unit conversionAC/DCMeasurement mode switching, etc.
SA6 Six Channel Spectrum Analyzer - Technical Parameters:
model |
SA6 |
performance parameter | |
Number of input channels |
6A channel. 2Group, each group3Input channels (data from 3D flux gate sensors, accelerometers, or acoustic sensors) |
Input signal range |
±10Vsingle-ended |
Input frequency range Magnetic Field Accelerators and acoustic sensors |
highest1kHz DCto1kHz (DCcoupling);5Hzto1kHz (ACcoupling) |
resolution |
24High precision positioningA/Dconverter |
Sampling rate |
1-2000spsMaximum sampling interval1s |
storage |
Can collect up to700,000Sample data (depending on computer storage space) |
Frequency domain display options |
DCData sources andACdata source |
Analog gain control |
Can be selected on the software1Double2Double4Double8Double16Double32times |
Spectrum range |
Select sampling rate or maximum frequency through software |
Sensor Input |
single-ended(Unbalanced) |
Requirements for 3D Flux Gate Sensors |
Power Supply:±15Vor User Specified Output signal:±10V/axle(Unbalanced, single ended reference0V)or User Specified give an example:BartingtonBrand's 3D flux gate sensorMag-03、Mag-13、Mag690;COLIYBrand'sF901、F902、F905class |
Requirements for accelerometers |
Power Supply:±15Vor User Specified Signal output ratio:1V/gor10V/g |
Acoustic sensor or any other sensor |
Power Supply:±15Vor User Specified Signal output ratio: User specified |
Environmental requirements | |
operation temperature |
-10℃to +50℃ |
storage temperature |
-20℃to +70℃ |
Related humidity |
0 to90%non-condensing |
specifications | |
size |
200mm W × 75mm H × 150mm L |
weight |
1.25kg |
output interface |
USB |
Input Interface |
2individual10Core waterproof connectors and6individualBNCinterface |
Housing material |
aluminum alloy |
power interface |
USB TYPE C 5V 1A |
Digital Output |
USB TYPE A |
Optional Accessories
type |
describe |
Software-spectrum |
SMART PC Software(Upper computer software)Spectrum analysis function |
PS2005 |
Power adapter: Input100VAC- 240VAC Output voltage:5VDC,±5% Rated output current:2A |
power bank |
Any commercially available power bank Output voltage:5VDC,±5% Rated output current:>1A |
※※※Click to view other magnetic measurement devices ※※※ |