Residual chlorine ozone meter CL7687Provide:
-Display measurement values based on the range of the matching sensor
-Automatic measurement and control function;
-Low/high measurement, set point timeout operation, and logic input control alarm;
-Programmable dual analog output, used for recording and obtaining measurement values or PID regulation;
-The hold/alarm function activated by two external passive contacts;
-Automatic/manual automatic cleaning function.
Residual chlorine ozone meter CL7687The controller can be used in conjunction with constant voltage or polarographic electrodes.
If RTD Pt 100 or RTD Pt 1000 is connected, manual and automatic temperature compensation can be provided.
When connected to RTD, the instrument can also provide temperature readings
Fully functional display controller, suitable for industries such as sewage treatment, tap water, purified water, swimming pools, bottle washing, etc; multiple
Turn on/off PID/PFM/PWM control; Range 0-200.0 ppm; Large Screen Display
- Front panel with waterproof buttons and aluminum casing
- High reliability and accuracy, suitable for all application environments
- Built in data recording function with USB interface for easy downloading of data
- Backlit graphic display device with RS485 communication function
● Display measurement values, with optional ranges from -9999 to 9999 corresponding ● Select the decimal point position for the displayed value ● Input current value 0/4-20mA Can provide DC power supply for two-wire transmitters ● Single input or differential input ● Measurement units can be selected ● Set the range of measurement ● Select software filtering function ● Switch control and PID regulation function ● PFM/PWM or 4-20mA regulation control function |
Two control relays are used for upper and lower limit control functions Provide upper and lower limit alarm function for measured values The normally open and normally closed state of the alarm relay contacts is optional ● Output range and input range linkage ● Analog output value 4-20mA/0-20mA optional ● Activate, hold, and alarm functions through two external contacts ● Automatic and manual automatic cleaning control functions This instrument is suitable for dual channel deviation measurement and control ● Cooperate with two identical measurement signal inputs of the same range The signal of the input 0/4-20mA transmitter is commonly used for measuring the deviation of detection values before and after the process. |
- Measurement parameters: PH-ORP Conductivity Dissolved oxygen Residual chlorine Dissolved ozone Chlorine dioxide Turbidity Dissolved nitrite/sulfide Other outputs: ± 4…20mAsignal
- Two way control point relay switch function, PID (OWM-PFM) function
- Alarm relay, adjustable upper and lower limit values and delay - automatic cleaning relay
- Dual analog output, 0/4….20mAFull range arbitrary setting
- Power supply: 85~~264Vac_ optional: 9~36Vdc or 24Vac
- Dimensions: 96 * 96 * 95mm
|
|
B&CThe constant voltage electrode provided by the company has the following major advantages:
-The measuring and counting electrodes are both made of platinum, which can prevent corrosion from any liquid,
-The reference electrode is gel electrolyte and ring connection, which can ensure good liquid contact and low impedance,
-The electrode is a composite type, which is very easy to clean and replace,
-The electrode can be easily inserted into the flow channels SZ7231 and SZ7233, and the water flow can be relatively stable through the flow channels,
-Both metal electrodes are annular electrodes.
The measuring electrode is located at the top, and the counting electrode is located at the bottom. It is very important to note that the electrodes should not be reversed during installation. The following are the correct installation steps:
It is very important to insert the electrodes into the flow channels SZ7231/SZ7233 in the correct position. If other flow channels are used, it is necessary to maintain a constant flow rate to avoid fluctuations in readings due to changes in flow rate.
Italy's best-selling instruments also include the 7685 series, such asMagnetic residual chlorine monitor CL7685 PH7685.010 dual channel pH meterMagnetic TU7685