RM-6280C Multi channel Physiological Signal Acquisition and Processing System
8 channels, all of which are multifunctional fully controlled isolated amplifiers. Each channel amplifier can be used as a bioelectric amplifier, bloo
Product details
  • Product Name: RM-6280C Multi channel Physiological Signal Acquisition and Processing System
  • Order number: tlyon000456
  • Brand Name: Sichuan Chengyi
If you find that the product information is inaccurate, please feel free to correct it; For inquiries about related categories and brand products, please contact us

Product Introduction:
The system adopts a true external structure. Suitable for both laptops and desktop computers. Interface with computer: USB2.0。 Due to the independent circuit board used for the internal A/D acquisition part of the system (inside the external chassis), no matter how the interface technology of the computer develops in the future, the instrument can adapt to the development of the computer by replacing the A/D acquisition module and corresponding software, and the instrument upgrade is very convenient. The stimulator adopts an optocoupler fully isolated system and 12 lead modes with international standards for ECG.
Independently develop system software.
Having a software product registration certificate. Certificate No.: Chuan DGY-2013-0154
Computer software copyright registration certificate. Registration number: 2012SR137470
Hardware technical specifications:
1. The instrument adopts an integrated anti-interference power supply with AC 220V. Except for the built-in transformer in the chassis, there is no need to connect any external transformer, ensuring that the instrument can display clear and accurate bioelectric signals without any external grounding wire during any bioelectric experiment. This ensures the anti-interference performance and accuracy of the device.
2. The instrument has 8 channels, all of which are multifunctional fully controlled isolated amplifiers. Each channel amplifier can be used as a bioelectric amplifier, blood pressure amplifier, bridge amplifier, as well as a spirometer, thermometer, etc. And each channel has independent hardware modules that are mutually independent, greatly increasing the anti-interference ability between channels, and also bringing great convenience to instrument maintenance and repair.
3. Adopting high-precision 16 bit A/D conversion chip, the maximum sampling rate of single channel hardware is 1000KHz. The minimum hardware sampling rate is 0.01Hz. The maximum sampling frequency during eight channel continuous sampling is 100kHz, and the sampling rate can be changed as needed during real-time sampling.
4. Scanning speed: 0.05m/div~3200s/div.
5. Amplifier input resistance ≥ 100M Ω (dual ended input) and 50M Ω (single ended input), common mode rejection ratio ≥ 100dB, noise ≤± 1 μ V (RMS) or ≤± 3 μ V (P-P).
6. Frequency response: DC~20kHz。
7. Input range: 5 μ V~500mV.
8. Sensitivity:
a) Bioelectric mode: 20uV/div~500mV/div
b) Blood pressure mode 3.6-360 (mmHg/div) 0.36-180 (mmHg/div) (high-sensitivity transducer)
9. AC and DC have the same gain: adjustable ranges of 500mv, 200mv, 100mv, 50mv, 20mv, 10mv, 5mv, 2mv, 1mv, 500uV, 200uV, 100uV, 50uV, 20uV, and 10uV; It can directly input a 10V electrical signal without saturating the amplifier.
10. Low pass filtering (hardware): 0.3 Hz 3 Hz, 10Hz, 30Hz, 100Hz, 500Hz, 1kHz, 3kHz, 10 kHz OFF(20kHz)。 Having filtering methods of 5 or more orders.
11. Time constants (hardware): 0.001s, 0.002s, 0.02s, 0.2s, 1s, 5s DC。
12. The main technical requirements for optoelectronic isolated programmable stimulators include single stimulation, serial single stimulation, continuous single stimulation, dual stimulation, serial dual stimulation, continuous dual stimulation, timed stimulation, intensity increasing stimulation, frequency increasing stimulation, wave width increasing stimulation, strong interval increasing stimulation, and automatic serial dual stimulation. Maximum load current: 100 mA, with positive and negative current output modes, meeting national safety standards for experimental electricity use, and will not cause electric shock due to misoperation. Output voltage<=50V to meet national safety electricity standards.
13. Digital filtering mode:
1) Adjustable high pass, low-pass, band-pass, and bandstop filtering parameters.
2) Zero phase shifted digital filtering with adjustable order.
14. The hardware system includes an ECG full lead card, with each channel capable of producing 12 different lead modes for electrocardiograms. The lead switching mode can be programmed, with a total of 12 lead modes available I II, III aVR、 aVL、 aVF、 V1、 V2、V3、V4、V5、V6。

Software technical performance:
1. Possess a software product registration certificate. Certificate No.: Chuan DGY-2013-0154
Computer software copyright registration certificate. Registration number: 2012SR137470
2. It has monitoring and drip recording functions, and drip recording has dedicated analysis and counting software.
3. Two devices can be combined to form a new 16 channel recorder, with independent 8-channel and 16 channel software. The software can freely set 1-16 display channels.
4. Includes physiological, pharmacological, and pathophysiological experimental projects, with a minimum of 50 experimental projects; And it can wirelessly expand experimental projects according to user needs (define parameters by oneself). It has flexible dimension conversion function, which stores various parameters such as zero position, dimension conversion ratio, and experimental parameters of various experiments in the database, and can be flexibly and quickly called and modified.
5. Supports waveform data export function, which can be opened by software such as Matlab, SPSS, Sas, etc. Customizable open data interface for secondary development of software. Users can write their own software to collect, record, and analyze experimental waveform data.
6. Support external stimulus capture module and synchronized display with blood pressure and oxygen monitoring device. Microcirculation synchronous video display and recording; And it can be used in conjunction with video teaching systems. Synchronize the recording of physiological signals and video signals, and support synchronous playback.
7. It has data analysis functions such as integration, differentiation, frequency histogram, sequence/non sequence density histogram, and two-dimensional and three-dimensional spectrum analysis.
8. Software integration dedicated pharmacological analysis toolbox, integrating multiple pharmacological analysis tools, such as PA2 calculation, LD50 calculation using Bliss method, t-test calculation Regression analysis, etc. Equipped with automatic statistical analysis function for electrocardiogram. Capable of heart rate variability (HRV) analysis. Capable of myocardial cell action potential LTP、 Specialized measurement and analysis functions for EEG, cellular, and neural discharges. Equipped with dynamic automatic measurement functions for electrocardiogram, blood pressure, intraventricular pressure, pulse, respiration, etc. It has the functions of quantitative respiratory flow measurement and respiratory mechanics index determination, and can also be used for measuring human lung ventilation.
9. Data result export, import, backup, and save functions, as well as data power-off recovery function. The data measurement results can be displayed in the form of a floating data board or channel display. The software has waveform sound playback function, which plays experimental waveforms in audio format. (Sound reproduction in experiments such as decompression nerve discharge, heart sounds, cochlear microphonic potentials, etc.).
10. The supporting software has a software product registration certificate and a computer software copyright registration certificate;
The software can be paired with an English version and is suitable for foreign education. Equipped with a contextual assistance system.
11. The software has a split waveform function (i.e. left view function), which is used to observe the recorded waveforms at any time during the recording process and align them for relevant data analysis.
12. WINDOWS traditional software interface, supporting XP, WIN7/8/10 operating systems.

Main accessories:(Additional configurations can be changed according to user needs)
1- One host;
2. One set of analysis software for biological signal acquisition and processing system;
One USB 2.0 signal cable accessory;
4- Shielding and protecting 4 bioelectric signal input lines; 1 stimulation output line; Record one input line.
5. Import one three-way connector; One venous pressure measuring tube;
6-Blood pressure sensor 1 (-10~40kPa) calibration transducer
7-Muscle Tension Sensor 1 (0-50g) Calibration type transducer
7-International standard ECG full lead lead family 1

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content