VIP member
RKD Circular Core - Protection and Isolation Transformer
RKD Circular Core - Protection and Isolation Transformer
Product details
RKD
Circular iron core - protection and isolation transformer
, PRI 2 x 115 Vac, SEC 2 x 6 – 2 x 115 Vac, 15 – 3.000 VA
General data
Power 15-3.000 VA
The maximum ambient temperature is 40 ° C
Insulation material grade B
Effectiveness up to 98%
Measure the output voltage of 2 x 6-2 x 115 Vac
Measure input voltage 2 x 115 Vac
Protection level IP 00
advantage
Ensure minimum specifications at high power
Minimum no-load loss
Suitable for series or parallel dual input/output voltage
A smaller leakage magnetic field can achieve excellent temperature performance
Extremely small noise field
light weight
standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with: VDE 0570 Parts 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
A transformer specifically designed for voltage regulation and simple electrical isolation.
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
Circular iron core - protection and isolation transformer
, PRI 2 x 115 Vac, SEC 2 x 6 – 2 x 115 Vac, 15 – 3.000 VA
General data
Power 15-3.000 VA
The maximum ambient temperature is 40 ° C
Insulation material grade B
Effectiveness up to 98%
Measure the output voltage of 2 x 6-2 x 115 Vac
Measure input voltage 2 x 115 Vac
Protection level IP 00
advantage
Ensure minimum specifications at high power
Minimum no-load loss
Suitable for series or parallel dual input/output voltage
A smaller leakage magnetic field can achieve excellent temperature performance
Extremely small noise field
light weight
standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with: VDE 0570 Parts 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
A transformer specifically designed for voltage regulation and simple electrical isolation.
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
variant | Measure input voltage | Measure output voltage | measured power |
RKD 15/2x6 | 2 x 115 Vac | 2 x 6 Vac | 15 VA |
RKD 15/2x9 | 2 x 115 Vac | 2 x 9 Vac | 15 VA |
RKD 15/2x12 | 2 x 115 Vac | 2 x 12 Vac | 15 VA |
RKD 15/2x15 | 2 x 115 Vac | 2 x 15 Vac | 15 VA |
RKD 15/2x18 | 2 x 115 Vac | 2 x 18 Vac | 15 VA |
RKD 20/2x12 | 2 x 115 Vac | 2 x 12 Vac | 20 VA |
RKD 20/2x15 | 2 x 115 Vac | 2 x 15 Vac | 20 VA |
RKD 20/2x18 | 2 x 115 Vac | 2 x 18 Vac | 20 VA |
RKD 20/2x24 | 2 x 115 Vac | 2 x 24 Vac | 20 VA |
RKD 30/2x6 | 2 x 115 Vac | 2 x 6 Vac | 30 VA |
RKD 30/2x9 | 2 x 115 Vac | 2 x 9 Vac | 30 VA |
RKD 30/2x12 | 2 x 115 Vac | 2 x 12 Vac | 30 VA |
RKD 30/2x15 | 2 x 115 Vac | 2 x 15 Vac | 30 VA |
RKD 30/2x18 | 2 x 115 Vac | 2 x 18 Vac | 30 VA |
RKD 30/2x24 | 2 x 115 Vac | 2 x 24 Vac | 30 VA |
RKD 40/2x6 | 2 x 115 Vac | 2 x 6 Vac | 40 VA |
RKD 40/2x9 | 2 x 115 Vac | 2 x 9 Vac | 40 VA |
RKD 40/2x12 | 2 x 115 Vac | 2 x 12 Vac | 40 VA |
RKD 40/2x15 | 2 x 115 Vac | 2 x 15 Vac | 40 VA |
RKD 40/2x18 | 2 x 115 Vac | 2 x 18 Vac | 40 VA |
RKD 40/2x24 | 2 x 115 Vac | 2 x 24 Vac | 40 VA |
RKD 50/2x12 | 2 x 115 Vac | 2 x 12 Vac | 50 VA |
RKD 50/2x15 | 2 x 115 Vac | 2 x 15 Vac | 50 VA |
RKD 50/2x18 | 2 x 115 Vac | 2 x 18 Vac | 50 VA |
RKD 50/2x24 | 2 x 115 Vac | 2 x 24 Vac | 50 VA |
RKD 60/2x6 | 2 x 115 Vac | 2 x 6 Vac | 60 VA |
RKD 60/2x9 | 2 x 115 Vac | 2 x 9 Vac | 60 VA |
RKD 60/2x12 | 2 x 115 Vac | 2 x 12 Vac | 60 VA |
RKD 60/2x15 | 2 x 115 Vac | 2 x 15 Vac | 60 VA |
RKD 60/2x18 | 2 x 115 Vac | 2 x 18 Vac | 60 VA |
RKD 60/2x24 | 2 x 115 Vac | 2 x 24 Vac | 60 VA |
RKD 60/2x30 | 2 x 115 Vac | 2 x 30 Vac | 60 VA |
RKD 80/2x12 | 2 x 115 Vac | 2 x 12 Vac | 80 VA |
RKD 80/2x15 | 2 x 115 Vac | 2 x 15 Vac | 80 VA |
RKD 80/2x18 | 2 x 115 Vac | 2 x 18 Vac | 80 VA |
RKD 80/2x24 | 2 x 115 Vac | 2 x 24 Vac | 80 VA |
RKD 100/2x9 | 2 x 115 Vac | 2 x 9 Vac | 100 VA |
RKD 100/2x12 | 2 x 115 Vac | 2 x 12 Vac | 100 VA |
RKD 100/2x15 | 2 x 115 Vac | 2 x 15 Vac | 100 VA |
RKD 100/2x18 | 2 x 115 Vac | 2 x 18 Vac | 100 VA |
RKD 100/2x24 | 2 x 115 Vac | 2 x 24 Vac | 100 VA |
RKD 100/2x30 | 2 x 115 Vac | 2 x 30 Vac | 100 VA |
RKD 120/2x9 | 2 x 115 Vac | 2 x 9 Vac | 120 VA |
RKD 120/2x12 | 2 x 115 Vac | 2 x 12 Vac | 120 VA |
RKD 120/2x15 | 2 x 115 Vac | 2 x 15 Vac | 120 VA |
RKD 120/2x18 | 2 x 115 Vac | 2 x 18 Vac | 120 VA |
RKD 120/2x24 | 2 x 115 Vac | 2 x 24 Vac | 120 VA |
RKD 120/2x30 | 2 x 115 Vac | 2 x 30 Vac | 120 VA |
RKD 160/2x12 | 2 x 115 Vac | 2 x 12 Vac | 160 VA |
RKD 160/2x15 | 2 x 115 Vac | 2 x 15 Vac | 160 VA |
RKD 160/2x18 | 2 x 115 Vac | 2 x 18 Vac | 160 VA |
RKD 160/2x24 | 2 x 115 Vac | 2 x 24 Vac | 160 VA |
RKD 160/2x30 | 2 x 115 Vac | 2 x 30 Vac | 160 VA |
RKD 160/2x35 | 2 x 115 Vac | 2 x 35 Vac | 160 VA |
RKD 200/2x12 | 2 x 115 Vac | 2 x 12 Vac | 200 VA |
RKD 200/2x15 | 2 x 115 Vac | 2 x 15 Vac | 200 VA |
RKD 200/2x18 | 2 x 115 Vac | 2 x 18 Vac | 200 VA |
RKD 200/2x24 | 2 x 115 Vac | 2 x 24 Vac | 200 VA |
RKD 225/2x12 | 2 x 115 Vac | 2 x 12 Vac | 225 VA |
RKD 225/2x15 | 2 x 115 Vac | 2 x 15 Vac | 225 VA |
RKD 225/2x18 | 2 x 115 Vac | 2 x 18 Vac | 225 VA |
RKD 225/2x24 | 2 x 115 Vac | 2 x 24 Vac | 225 VA |
RKD 225/2x30 | 2 x 115 Vac | 2 x 30 Vac | 225 VA |
RKD 250/2x12 | 2 x 115 Vac | 2 x 12 Vac | 250 VA |
RKD 250/2x18 | 2 x 115 Vac | 2 x 18 Vac | 250 VA |
RKD 250/2x24 | 2 x 115 Vac | 2 x 24 Vac | 250 VA |
RKD 250/2x30 | 2 x 115 Vac | 2 x 30 Vac | 250 VA |
RKD 300/2x12 | 2 x 115 Vac | 2 x 12 Vac | 300 VA |
RKD 300/2x18 | 2 x 115 Vac | 2 x 18 Vac | 300 VA |
RKD 300/2x24 | 2 x 115 Vac | 2 x 24 Vac | 300 VA |
RKD 330/2x18 | 2 x 115 Vac | 2 x 18 Vac | 330 VA |
RKD 400/2x18 | 2 x 115 Vac | 2 x 18 Vac | 400 VA |
RKD 400/2x24 | 2 x 115 Vac | 2 x 24 Vac | 400 VA |
RKD 400/2x30 | 2 x 115 Vac | 2 x 30 Vac | 400 VA |
RKD 500/2x24 | 2 x 115 Vac | 2 x 24 Vac | 500 VA |
RKD 500/2x30 | 2 x 115 Vac | 2 x 30 Vac | 500 VA |
RKD 500/2x35 | 2 x 115 Vac | 2 x 35 Vac | 500 VA |
RKD 625/2x30 | 2 x 115 Vac | 2 x 30 Vac | 625 VA |
RKD 625/2x115 | 2 x 115 Vac | 2 x 115 Vac | 625 VA |
RKD 800/2x40 | 2 x 115 Vac | 2 x 40 Vac | 800 VA |
RKD 800/2x115 | 2 x 115 Vac | 2 x 115 Vac | 800 VA |
RKD 1000/2x50 | 2 x 115 Vac | 2 x 50 Vac | 1.000 VA |
RKD 1000/2x115 | 2 x 115 Vac | 2 x 115 Vac | 1.000 VA |
RKD 1200/2x115 | 2 x 115 Vac | 2 x 115 Vac | 1.200 VA |
RKD 1600/2x115 | 2 x 115 Vac | 2 x 115 Vac | 1.600 VA |
RKD 2000/2x115 | 2 x 115 Vac | 2 x 115 Vac | 2.000 VA |
RKD 3000/2x115 | 2 x 115 Vac | 2 x 115 Vac | 3.000 VA |
Product specification sheet download
RKD_datasheet
Online inquiry