Shanghai Yuanben Magnetoelectric Technology Co., Ltd
Home>Products>RFSS series non-contact safety switch
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    6133 Huyi Road, Jiading District, Shanghai
Contact Now
RFSS series non-contact safety switch
RFSS series non-contact safety switch
Product details


接近安全全家图.jpg


RFSS seriesnon-contactsafety switch

Overview

RFSSseriesnon-contactsafety switchyesbased onRFID technologySpecially designed for safety circuitsSafety switches, compared to mechanical or magnetic switches, havehigherConfidentiality testingsexStrong anti-interference ability, Characteristics such as safety and reliability.Built in codec device, withThree different encoding methods (standard, independent.Being able to be independent.The best way,Equipped with tamper proof performanceIt can effectively prevent missed or false alarms, or human abnormal triggering. Adopting secure dual channel output technology for safety levelPerformance achievedPLe/ SIL3,Compliant with(EN ISO 13849-1) (EN 62061)Waiting for international standards, can be applied toMobile protective devices (e.gMonitoring of safety doors, protection of top covers and flaps, safety door locks)Location monitoring,Prevent unauthorized entry, used to prevent personnel from being injured by dangerous movements, or to prevent interference with production processes, etcplantStrict monitoring or prevention is requiredHigh risk situations.reach, achieve, attainIP67 orIP69KProtection level, can be used in harsh equipment environments.Adopting composite engineeringPlastic shell material,Characterized by easy cleaning and long service life.with the help ofM12Interface, capable of quickly achieving system integration.

Main features

nCompliant with(EN ISO 13849-1) (EN 62061)Waiting for international standards

nsecurity levelPerformance achievedPLe/SIL3

nbased onrfid technologyEquipped with tamper proof performance, haveThree different encoding methods

nreach, achieve, attainIP67 andIP69KProtection levelUsed in harsh equipment environments

nCable length2-meter or 150mm beltM12Interface, capable of quickly achieving system integration

nPBT or PA engineeringPlastic shell material,Easy to clean and have a long service life

nStrong anti-interference ability, Characteristics such as safety and reliability

Technical Specifications

security level

standard

ISO13849-1, IEC/EN60947-5-3,EN 62061

security classification

comply withISO13849-1Cat4/ SIL3, Dual channel interlockreachablePLe

Technical Specifications

Safety output

2XPNPNormally Open

Auxiliary output

1XPNPnormally closed(Non secure output)

working distance

conduct. Min15mm

safetyoutput current

200mA

Working Voltage

24VDC±15%

operating current

50mA

response time

50ms

Protection level

IP67(The sealing process needs to be verified)

operating frequency

10 Hz

Operating Temperature

-10~+60

relative humidity

5...95%

shellmaterial

PBTorPA


RFIDSafety switch wiring

serial number

signal definition

Color

Explanation

1

24V

brown

Power supply positive (connected to 24)V±15%)

2

0V

blue

Negative power supply

3

Enter A+

black

Cascade input (connected to 24)V±15%)

4

Enter B+

Huang

Cascade input (connected to 24)V±15%)

5

Output A

white

Normally open safety output A

6

Output B

green

Normally open safety output B

7

Auxiliary input positive pole

powder

Normally closed input (no power supply required)
(Cannot be directly grounded, otherwise there will be a short circuit)

8

Auxiliary output

gray

Normally closed output

Indicator light status

LEDdisplay


Output State


Status Description

Normally open floating outputA

Normally open floating outputB

Normally closed outputC

Green light always on

sever

sever

through

No actuator or incomplete alignment

green light4Hzflash

sever

sever

through

Unrecoverable error, check input lineATheB

The red light is always on

through

through

sever

Induction is normal, position aligned

protect

short circuit protection

Current Limit

overload protection

Overvoltage protection

Overheating stop and restart

reverse polarity protection

Transient noise protection

Failure pulse protection

integration

integration

integration

integration

integration

integration

integration

integration

State verification operation method

1.Check if the power supply voltage is24VDC,Connect the red, black, and yellow wires of the sensor to the positive pole of the power supply, and connect the blue wire to the negative pole of the power supply.

2.If the sensor and actuator positions are not aligned, you can see that the green indicator light is constantly on and the normally closed output is in a power-off state. At the same time, the normally open input (pink line) and normally open output (gray line) are in a conducting state.

3.If the sensor is aligned with the actuator position, the red indicator light will light up and the normally closed output will be in a conducting state (at this time, there is real voltage output on the white and green lines).


RFSSseriesRFIDSafety switch size(mm

RFSS1.jpg


product image

RFSS白底.jpg

RFSSseriesnon-contactSafety switch approaching direction diagram

345.jpg

Notes:

The sensing distance will change When the sensor is installed on a metal surface, it can also be clamped between the sensor and the metal surface with a non-metallic plate to reduce the impact. Before officially using the control system,All security functions must be thoroughly tested.

RFSSseriesRFIDApplication wiring example of safety switch without cascade function


Electrical connection diagram

QQ截图20191118095004.jpg