Q-S153 Infrared Carbon Dioxide Analyzer
Application: Q-S153 Infrared Carbon Dioxide Analyzer is a single channel non diffusive infrared carbon dioxide analyzer, suitable for measuring carbon
Product details

Purpose:

The Q-S153 infrared carbon dioxide analyzer is a single channel non diffusive infrared carbon dioxide analyzer suitable for measuring carbon dioxide exchange in animals or high carbon dioxide flux environments, and can measure in real-time and continuously.


characteristic:
·Switch between two measurement ranges: 0-5% and 0-10%;
·Display a resolution of 0.01% for carbon dioxide;
·Adopting non diffusive infrared analysis technology;
·Integrated infrared light source, no need to move;
·0-5V analog output;
·Optional portable battery power supply;
·Compact in size, lightweight and easy to carry.


Application:
·Mammalian respiration;
·Analysis of gases exhaled by the human body;
·Compost monitoring;
·Monitoring anaerobic metabolism in yeast.

Q-S153红外二氧化碳分析仪


Technical specifications:

Working principle

Non diffusive infrared analyzer

Gas sampling mode

Flowing gas, sealed sample chamber

Maximum flow velocity range

650 milliliters per minute

Maximum measurement range

0~10% (LCD display)

Analog Output

Low sensitivity 0~10%, high sensitivity 0~5%

accuracy

± 0.3% of the full range

repeatability

Better than ± 1%

Maximum drift

± 0.5%/year

reaction time

About 20 seconds (at 250 milliliters per minute, 95% probability)

Warm-up time

About 5 minutes (at 22 ℃)

Linear output

Low sensitivity 0~5V DC corresponds to 0~10%, high sensitivity 0~5V DC corresponds to 0~5%

Calibration adjustment

Zero point and interval

Working temperature range

0~50℃

Storage Temperature Range

-40~+70℃

Working pressure range

± 1.5% local average air pressure

Operating humidity range

5~90% RH, non condensing (recommended gas after moisture absorption)

pressure dependence

+0.19% reading/mm Hg

power supply

12V DC 120V AC/60Hz adapter

Current demand

Average 175mA, peak 450mA

size

5.5~9.5 × 9.5 × 17 centimeters (H × W × D)

weight

1 kilogram