Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd
Home>Products>Purity and impurity content analysis of sec butanol by gas chromatography
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18663278921
  • Address
    No. 20, Xibeitan, Tengzhou City, Shandong Province
Contact Now
Purity and impurity content analysis of sec butanol by gas chromatography
Product Introduction: We are honored to recommend the gas chromatography method for determining the purity and impurity content of sec butanol. Gas ch
Product details
brand ZKP/Zhongkepu

Sec butanol is an important chemical raw material and intermediate, which can be used as a raw material for the production of methyl ethyl ketone, spices, dyes, lubricants, flotation agents, as well as solvents, emulsifiers, dye dispersants, dehydrators, paint removers, and industrial detergents. Tengzhou Zhongkepu adopts gas chromatographyQualitative analysis of impurities in industrial sec butanol products was carried out using chromatography, and the target components for gas chromatography analysis were determined. At the same time, R tx-200 capillary chromatography column was used to analyze the purity and impurity content of sec butanol. All impurities were well separated, and the accuracy and repeatability of quantitative analysis were good.

Instrument configuration and reagents

Product Name

Configuration plan

quantity

Gas chromatograph

GC-2020Equipped with (hydrogen flame detector+capillary injection system)

1platform

data processing

Chromatography workstation

1set

Chromatographic column

R tx - 200 ( 0. 32mm*60m*0. 5um )

1only

External air source

Nitrogen hydrogen air cylinder or generator

1set

computer

Brand computer XP system

1platform

GC-2020 gas chromatographPerformance characteristics

1. Adopting320 x 240lattice5.7An inch large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
2Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
3Six independent temperature controls (vaporization chamber and capillary vaporization chamber can be independently controlled), Five level program heating function;
4Overtemperature Protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
5The vertical heating device of * makes sample vaporization more reliable, reduces the heat radiation generated in the vaporization chamber to the minimum, and ensures minimal temperature deviation inside the column box;
6Intelligent fuzzy control rear door opening system, automatically tracks temperature and dynamically adjusts The angle of the air door can achieve precise temperature control even near room temperature;
7Configure filling column head injection, glass lining injection, with diaphragm cleaning Functional capillary diversion/Non split injection device and capable of installing gas injectors;
8High precision dual stable gas path, capable of installing four types of detectors simultaneously;
9
Optional electronic flow pressure display system with built-in workstation device.

Temperature control indicators
1.Temperature control range: room temperature
5400increment0.1
2.Temperature control accuracy: superior to±
0.01

Program heating: Five step interval constant temperature time0999minincrement0.1minTemperature increment0.1
Heating rate:
200The biggest one below40/min200Up to the biggest20/min

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!