The CW-700S Total Organic Carbon Analyzer is a structurally simple instrument. The main components are installed on the host, and before measurement,
Product details
Working principle
CW-700S Total Organic Carbon AnalyzerAdopting the principle of UV persulfate oxidation NDIR detection. One sample is fully oxidized and decomposed into CO2 through UV and persulfate, while the other sample is decomposed into CO2 through acid reagents. Under the action of a carrier gas, CO2 is dried and purified before entering a non dispersive infrared detector (NDIR) for determination of carbon concentration in the sample.
CW-700S Total Organic Carbon AnalyzerTechnical Parameter
Analysis method: UV persulfate oxidation NDIR detection principle
Detectable items: TC、IC、TOC、NPOC
TOC detection range: 0.001~100.0mg/L
TOC detection accuracy: 0.001mg/L
TOC accuracy error: ≤ ±5%
Injection volume: 50-6000ul
Analysis time: 3-8 minutes
Repetitive error: ≤ 3%
Zero drift: ≤ ±2%/D
Range drift: ≤ ±2%/D
Test condition oxidant: Sodium persulfate solution
Acid reagent: phosphoric acid solution
Carrier gas: high-purity nitrogen (carbon dioxide free air)
Environmental requirements: Environmental temperature: 0-40 ℃
Relative humidity: ≤ 85%
Power Requirements: 220V AC ≤± 10% 50Hz
Power: 150W
Basic dimensions: 38cm × 30cm × 32cm
Weight: 20kg
Performance characteristics
Meets the requirements of EP, USP, and the 2015 edition of the Chinese Pharmacopoeia;
Three detection modes: TC、TIC、TOC、NPOC, Conducted in the same reactor;
The highly reflective gold-plated gas chamber, highly concentrated infrared light source, and highly sensitive infrared detector ensure excellent performance of NDIR; Measuring ppb level data has sufficient sensitivity and accuracy;
Precise electromagnetic metering pump ensures the accuracy and stability of sample injection volume;
Dual tube electronic condensation dehydration technology;
The detection curve is visible in real-time, making it more intuitive;
Real time self-monitoring function for temperature, pressure, and flow at multiple locations;
The curve can be customized according to the measurement range to meet the measurement requirements of any water sample;
Optional online module for online monitoring;
L can be equipped with an automatic sampling device to achieve unmanned operation, saving manpower and time.
measuring software
Software meets GMP computer system validation:
Electronic signature
1) Login through username and password, with * attribute.
2) Passwords have length requirements to enhance security.
3) Equipped with manual screen locking function, ensuring operability and safety.
Permission management
1) Multi level permission settings.
2) Administrators can grant different permissions to other operators to ensure that they only have permissions equivalent to their job functions.
Data integrity
1) It has audit tracking function and cannot be closed.
2) All test results are saved and cannot be modified or deleted.
3) All operations are recorded (as long as there are traces of personnel entering).
4) If the detection method is modified, the modified parameters will be recorded.
5) Data can be exported and backed up to protect stored data for future access.