4146 |
4046 |
|
Flow measurement range |
0.01-20L/min |
2.5—300L/min |
accuracy |
± 2% reading or 0.005STDL/min, whichever is greater |
± 2% reading or 0.05STD L/min, whichever is greater |
External dimensions |
127 x 50 x 32mm |
183 x 64 x 53mm |
weight |
1.0Kg |
1.1Kg |
Warm-up time |
1min |
|
power supply |
7.5VDC ± 1.5V, peak current 300mA |
Flow calibrator
Model: 4046/4146
The accuracy of TSI flowmeter TSI4046TSI4146 sampling in the United States depends on flow measurement and laboratory analysis. In order to accurately measure the volume of air passing through the sampling medium, the air sampling instrument must adjust the flow rate, calibrate, and regularly check to ensure the accuracy of the flow rate. Practice has shown that personal sampling pumps must be calibrated before and after each use, and regularly checked during use.
TSI provides two types of flow calibrators for calibrating pumps or other active air sampling devices. The 4046 and 4146 flow calibrators have ranges of 2.5-300L/min and 0.01-20L/min, respectively. They all use batteries, are lightweight, portable, and easy to use. Continuous display of volumetric flow rate enables real-time adjustment of pump flow rate. In addition, the calibrator has temperature compensation and pressure correction functions. The measurement of volumetric flow rate can be accurate to 2% of the count.
Product characteristics
Provide continuous and real-time volumetric flow counting for convenient and quick adjustment of pump flow rate
Using batteries, compact and lightweight
Portable - Use the same calibrator for adjustment, calibration, and regular flow checks
Confirmed by NIOSH as a Level 1 Calibration Reference Instrument Technology
Having NIST calibration certificate
Complete accessories, ready for immediate use
Application scenarios
Industrial hygiene sampling
Environmental Sampling
Research on Indoor Air Quality
Infectious Disease Health Research
Special longitudinal session
Contains components
Calibrator, battery, tube, carrying case, NIST calibration certificate, user guide
TSI flowmeter from the United States, tsi4146,tsi4046,tsi4146, TSI flowmeter 4146 from the United States, TSI flowmeter 4046 from the United States, TSI4046 from the United States, TSI4146 from the United States
Remarks: TSI flow calibrator from the United States, TSI4046 from the United States, TSI4146 from the United States, TSI4046 from the United States, TSI flowmeter agent, agent of TSI flowmeter from the United States, flow calibrator, flow detection device, TSI flow calibrator 4046 from the United States, TSI flow calibrator 4146 from the United States, and agent of TSI flowmeter 4046/4146 from China Instrument Environmental Science and Technology Co., Ltd