Price of trace moisture analyzer for insulating oil
Product Introduction: The trace moisture analyzer for insulating oil is mainly used for analyzing the moisture content in insulating oil, transformer
Product details
brand ZKP/Zhongkepu

Introduction to the price and detailed parameters of the trace moisture analyzer for insulating oil

1、 Product Introduction

The measuring principle of this instrument is based on the classic water measurement method "Karl Fischer Coulomb coulometric method". This method has high testing accuracy and extremely low testing cost, making it the most specific and accurate chemical method. It can quickly determine the moisture content in liquids, solids, and gases within one minute, directly display the measurement results, and the measurement range is from 0.0001% (1ppm) to 100%. It is widely used in the petroleum, chemical, power, pharmaceutical, pesticide, railway industries, and scientific research institutions.

The sample measurement process is automatically controlled by the instrument, with stirring and measurement completed in about 60 seconds, and the measurement results are directly displayed; The fully enclosed titration system avoids the harm of reagents to operators; The 500ml Karl Fischer reagent that comes with it has significant advantages such as the ability to continuously measure samples for about 1000 times, avoiding excessive errors that may occur during other methods of measuring water content, thereby improving the quality indicators of the product.

2、 Compliant with standards:

GB6283-86Determination of Moisture Content in Chemical Products by Karl Fischer Method (General Method)

GB/T606-2003Chemical reagents - General method for determination of moisture - Karl Fischer method

GB/T11133-1989 "Determination of Water Content in Liquid Petroleum Products (Karl Fischer Method)"

SH/T0246 GB/T11133-1989 GB/T7380-1995 GB10670-1989 GB/T3776.1-1983

GB/T6023-1999、 GB/T1600 . GB7600 . B/T 18619.1 . SH/T 0255 and other method standards.

3、 Application areas:

liquid

Chemical industry: alcohols, ethers, esters, acids, alkanes, benzenes, amines, organic solvents, phenols

Organic products that are suitable for Karl Fischer method determination.

Petroleum and power industry: insulation oil, transformer oil, turbine oil and other oil products(Price of trace moisture analyzer for insulating oil

Pharmaceutical industry: pharmaceutical raw materials, etc

Pesticide industry: emulsifiers, etc

Other industries: lithium battery electrolytes, etc

solid

Solid substances with good solubility, such as various inorganic salts and citric acid

Gas

Natural gas, liquefied gas, fluorocarbons, butadiene, chloromethane and other gases

4、 Main features:

*Adopting a powerful new generation microprocessor with dual CPU design, the measurement electrode data is directly A/D sampled and converted;

*Imported Mitsubishi 8-inch color touch Chinese LCD display screen with reagent failure prompt function, extending the service life of reagents;

*Fully sealed titration cell bottle, avoiding contact between reagents and people, and also avoiding the influence of environmental humidity;

*The shell is made of high-quality ABS engineering plastic board, and the surface is treated with electrostatic spraying, which is corrosion-resistant and easy to clean;

*The blank current microprocessor automatically controls compensation, and the reagent can quickly reach equilibrium state;

*0-430mA high electrolysis current, high detection sensitivity and fast analysis speed;
*The instrument automatically measures the sample and displays the analysis results, and can automatically calculate the average value of multiple measurements of the sample;

*Automatic measurement resultsUnlimited storageCheck historical records at any time;

*Automatically calculate and print content such as ug/ppm/percentage content/mg/L/sample number/tester/experiment date, etc;

*Through the instrument's USB or RS232 interface, it can communicate and connect with laptops and microcomputers to achieve networked management;

*Multiple language display operation, instrument program can be upgraded when national standards are revised;

5、 Main technical indicators:

Display mode:

Imported Mitsubishi 8-inch color touch Chinese LCD display screen

Measurement method:

Microprocessor controlled electrolysis (Karl Fischer Coulomb method)

Electrolysis speed:

3.0 milligrams of water per minute

Electrolytic current:

0-430mA automatic control

Display measurement range:

0.01 micrograms of water -200 milligrams of water

Water content range:

0.0001%(1ppm)—100%

Sensitivity:

0.01 micrograms of water

Accuracy:

When the water content is between 2 micrograms and 100 micrograms, the error is ≤± 1ug,

When the water content is between 100 micrograms and 1000 micrograms, the error is ≤± 2.9ug,

When the water content is above 1000 micrograms of water, the error is ≤± 0.2% (excluding injection error)

Drift compensation:

Microprocessor automatic control

Mixing speed:

Adjustable control

Endpoint indication:

Screen display/print output/sound warning/endpoint indicator

Data input:

Touch screen operation input

Sample Number:

User

Storage function:

Unlimited storage of results

printer:

Low energy high-speed thermal printer, 44mm paper width

Print content:

Ug/ppm/mg/L/sample number/tester/date

Calendar/Clock:

Analyze time and date display and print output

Self checking function:

Automatic diagnosis of instrument faults

Special Features:

Can be connected to laptops and other computers, allowing for both online and independent work

Power consumption:

Less than 40W

External dimensions:

390×270×190mm

Usage environment:

Temperature 5 ℃-40℃, humidity? 85%

Power supply:

AC220V±10% 50HZ±2.5HZ

Weight:

About 7 kilograms

6、 Configuration:

Number Attachment Name Quantity/Unit
1 host, one unit
2 electrolytic cell bottles each
3 electrolytic electrodes, one
4 measuring electrodes, one
5 drying tubes, one
Six sealing gaskets, ten pieces
7 boxes of vacuum grease
One power cord of 8
9 magnetic stirring rods, one
One 10 0.5 μ L sampler
11. One 50 microliter sampler
A 12 100 microliter sampler
One 13ml sampler
14 Karl Fischer reagent bottle
15 manuals, one copy
16 Attachment 1
One 17 certificate of conformity

Service commitment:

Home delivery, startup debugging, and free training on instrument operation;

Warranty period of one year Within one year, any non-human error in the instrument will be covered by on-site warranty