Requirements for water quality in the precision machinery industry:
In the precision machinery industry, it is usually necessary to use 10uS/cm-0.1uS/cm (ultra) pure water or alkaline water with a pH of 9.5 or above to clean parts with a cleaning machine. Especially when alkaline water with a pH of 9.5 or above is used for cleaning, there is often no need to add additional cleaning agents to achieve the cleaning effect, which is both environmentally friendly and cost-effective.
Application scenarios:
Production and processing of automotive components;
Production and processing of aircraft and automotive engine blades;
☆ Laboratory and pilot workshop;
Production and processing of laser heads for printers and fax machines;
Production and processing of read-write heads and disks for optical drives and hard drives;
Production and processing of precision mechanical products with special requirements for other products
Typical process flow of the product:
☆ Tap water - Water pump - Multi medium filter - Activated carbon filter - Automatic dosing device - Security filter - High pressure pump - Primary reverse osmosis - Intermediate water tank - Intermediate water pump - UV sterilizer - EDI electric deionization device or mixed bed - Pure water tank - Pure water pump - Cleaning machine
☆ Tap water - Water pump - Multi medium filter - Activated carbon filter - Automatic softening bed - Security filter - Pressure pump - Electrolysis device - Alkaline water tank - Water pump - Cleaning machine