System Introduction
Application areas:Measure oxygen content on clean gas pipelines or containers in industrial equipment such as magnetic materials, oxygen plants, nitrogen generators, food packaging, and special industries.
Application furnace type:High temperature sintering furnace for magnetic materials, power battery mesh belt furnace, all nitrogen hydrogen hood protection furnace, hot treatment hair gas furnace, chemical hydrogenation reaction kettle, various vacuum furnaces, etc.
characteristic:The ZND probe adopts a complete set of SIRO2 sensors and ceramic heaters, with high measurement accuracy and long service life.
Low voltage DC heating (15V), no high voltage, safe and reliable for on-site use.
The appropriate probe size (ZND or ZND-E) can be selected according to the on-site situation
The system structure is simple and the failure rate is extremely low.
Oxygen probe measures ambient temperature: 0-700 ℃
● Transmitter alarm output: One channel alarm output
● Transmitter communication: RS485 isolated communication (optional)
● System range: 1-209000 ppm, 0.01-20.9 O2%
● System response time: < 2 seconds when the measured atmosphere changes at the probe measurement end
When inputting standard gas into the probe calibration hole: reach 95% response value within 3 seconds
● Transmitter output type: 0-10mA, 4-20mA, 0-5V, 1-5V isolated transmission output (optional)
System installation environment: Oxygen probe installation environment temperature: -10-60 ℃ (standard type) or -20-120 ℃ (high temperature environment type)
Installation environment temperature for transmitter and oxygen probe maintenance instrument: -10-50 ℃; Humidity<90%
Structure: The oxygen probe adopts a waterproof design, can be installed outdoors, and is explosion-proof (optional); The transmitter and maintenance device are both wall mounted and designed to be waterproof, and can be installed outdoors
Explosion proof grade: ExdII CT 6 (customized)
Customizable positive pressure zirconia oxygen analysis system!