Portable sampler, GLS portable sampler, with super compact structure, light weight, fast touch operation, smaller than full-size sampler, designed specifically for general or key pollution detection.
GLSSuitable for situations where standard size samplers cannot work. It has a super compact structure, light weight, and fast touch operation,GLS in nothing less than a revolution.
GLSOne of its characteristics isLD—90Liquid detector, which is compatible withIscoThe combination of pump speed measurement system ensures accurate sample volume and high repeatability for each sampling.
Exclusive fast touch operation
characteristic
&S226;Compact structure, diameter16.5inchinch
&S226;Weight less than25Ibs
&S226;Optional proportional sampling with or without delayed traffic
&S226;Foldable handle
Application scenarios
&S226;Maximum daily traffic monitoring
&S226;Rainstorm runoff
&S226;Rivers, lakes, and estuaries
&S226;Non point source pollution
&S226;Sewage discharge
&S226;Confluence overflow of sewer system
&S226;Industrial mandatory monitoring
technical parameter
Weight (in thousands) |
11.1kg |
Size(H×D) |
67.3cm×41.9cm |
Controller protection level |
IP67 |
Operating temperature |
0~49℃ |
Incoming water detector |
Using patented non water contact and non-conductive sensors for detectionLD90When the water sample reaches the pump head, it automatically compensates for the change in head height |
Program storage |
Non volatileROM |
Traffic signal requirements |
5 ~ 15VDCPulse, or25Millisecond insulated contact closure signal |
Number of programmable combination samples |
1-999A sample |
Sampling frequency selection |
from1Minutes to arrive99hour59Divide, to1Minutes are increments. Non equal time sampling is measured in minutes or clocks, or in1~9999Flow pulses with intervals |
Sampling method setting |
It can be triggered through methods such as equal time, non equal time, flow rate (controlled by flow module or external flow meter pulse), external events, etc |
Replacement cleaning settings |
Before each sampling,The suction pipe can automatically replace and clean up to3second,Users can set |
Program execution aborted/Restore Settings |
Can be set at most24By time/Date suspension/Instructions for restoring the running of the sampling program |
Controller self diagnosis |
automatic testingRAM、ROMPump, display panel, and bottle separator |
Size(H×W×D) |
125cm×66cm×66cm |
Sampling repeatability |
±10ml |
Sampling height |
7.9m |
Sample volume |
10-9990ml;1mlIncrements per unit |
Program storage |
1Program Sampling |