Anti corrosion glass rotor flowmeterProduct model: LZB、LZJ
Overview of anti-corrosion glass rotor flowmeter
The LZB/LZJ series glass rotor flowmeter is widely used in chemical, petroleum, light industry, medicine, environmental protection, food and metrology testing, scientific research and other departments to measure the flow rate of single-phase non pulsating fluids (liquids or gases).
The LZB/() F/LZJ - () F series corrosion-resistant glass rotor flowmeter has strong corrosion resistance and can detect the flow rate of acids (except hydrofluoric acid), alkalis, oxidants, and other corrosive gases or liquids. It is suitable for industries such as chemical, pharmaceutical, papermaking, and sewage treatment.
Appearance and installation dimensions
Company: mm
Diameter DN | A | B |
C |
D | E |
Connection form |
4 | 178 | 204 | 230 | Φ10 | 38.5 × 33 (front) | hose |
6 | 178 | 204 | 230 | Φ10 | 42 × 33 (front) | hose |
10 | 178 | 208 | 244 | Φ12 | 45 × 40 (front) | hose |
15 | Φ95 | Φ65 | 470 | Φ15 | 4-Φ14 | flange |
25 | Φ115 | Φ85 | 470 | Φ25 | 4-Φ14 | flange |
40 | Φ145 | Φ110 | 570 | Φ40 | 4-Φ18 | flange |
50 | Φ160 | Φ125 | 570 | Φ50 | 4-Φ18 | flange |
80 | Φ185 | Φ150 | 660 | Φ80 | 4-Φ18 | flange |
100 | Φ205 | Φ170 | 660 | Φ100 | 4-Φ18 | flange |
125 | Φ245 | Φ210 | 660 | Φ125 | 8-Φ18 | flange |
150 | Φ280 | Φ240 | 660 | Φ150 | 8-Φ22 | flange |
Note: Flange standard GB/T9119-2000 DN (15-50), DN (125-150) PN1.0MPa DN (80-100) PN0.6MPa
principle and structure
The flowmeter is mainly composed of a conical glass tube that expands from bottom to top and a float that moves up and down with the flow rate of the fluid (Figure 3). When the fluid flows through the conical tube from bottom to top, the lift S generated by the kinetic energy of the fluid on the float and the buoyancy A of the fluid cause the float to rise. When the sum of the lift S and buoyancy A is equal to the weight G of the float itself, the float is in equilibrium and stable at a certain height position. The scale on the conical tube indicates the flow rate value of the fluid.
The cone tube of LZB/LZB - () F flowmeter is a smooth inner wall tube (see Figure 4). For flowmeters with a diameter of DN15 or more, the float moves up and down through the guide rod to maintain stability; There are three guiding ribs on the inner wall of the cone tube of LZJ/LZJ - () F flowmeter, which keep the float stable (see Figure 5). Flow meters with a diameter of DN10 or less are connected by hoses and equipped with needle shaped flow control valves; Flow meters with a diameter of DN15 or above shall be connected with flanges.
Materials of components in contact with measuring fluids
components and parts | Model |
|||||
LZB-4、6、10 LZB-4F |
LZJ-6、10 LZJ-6F、10F |
LZB-15 25, 40 |
LZJ-15、25 40, 50 (F) |
LZB-50 80, 100 |
LZB-80 100(F) |
|
Float | 1Cr18Ni9Ti Stainless steel Φ |
Agate | 1Cr18Ni9Ti stainless steel |
Outsourced fluoroplastics | 1Cr18Ni9Ti stainless steel |
Outsourced fluoroplastics |
Base | HPb59-1 brass |
1Cr18Ni9Ti stainless steel |
Cast iron lined with polypropylene plastic | Cast iron lined with fluoroplastic* | Cast iron coated with anti-corrosion paint | Cast iron lined with fluoroplastic* |
Stop stop | polypropylene plastics | Fluoroplastic | polypropylene plastics | Fluoroplastic | cast iron | Fluoroplastic |
Sealing rings and gaskets | Nitrile rubber | VITON | Nitrile rubber | VITON | Nitrile rubber | VITON |
Guide rod | 1Cr18Ni9Ti stainless steel |
1Cr18Ni9Ti stainless steel |
Outsourced fluoroplastics |
Note: If the medium is an organic solvent, please specify when ordering.
Anti corrosion glass rotor flowmeterModel specifications and technical parameters
Diameter DN (mm) | Type Φ Number | measuring range | Cone tube length (mm) | accuracy class | Allow the tested fluid state | |||
Water, 20 ℃ | Air temperature: 20 ℃, 101325Pa | LZB/LZJ | LZB-()F LZJ-()F |
Temperature (℃) | pressure (MPa) |
|||
4 | LZB-4 LZB-4F |
(1~10)L/h (1.6~16)L/h (2.5~25)L/h |
(16~160)L/h |
160 | 2.5 | 4 | -20~+120 | ≤1 |
6 | LZB-6 LZJ-6 LZJ-6F |
(2.5~25)L/h (4~40)L/h (6~60)L/h |
(40~400)L/h (60~600)L/h (100~1000)L/h |
2.5 | ||||
10 | LZB-10 LZJ-10 LZJ-10F |
(6~60)L/h (10~100)L/h (16~160)L/h |
(100~1000)L/h |
|||||
15 | LZB-15 LZJ-15F |
(16~160)L/h |
(0.25~2.5)m3/h (0.4~4)m3/h (0.6~6)m3/h |
350 | ≤0.6 | |||
25 | LZB-25 LZJ-25F |
(40~400)L/h (60~600)L/h (100~1000)L/h |
(1~10)m/h (1.6~16)m3/h (2.5~25)m3/h |
|||||
40 | LZB-40 LZJ-40F |
(0.16~1.6)m3/h (0.25~2.5)m3/h |
(4~40)m3/h (6~60)m3/h |
430 | ||||
50 | LZB-50 LZJ-50F |
(0.4~4)m3/h (0.6~6)m3/h |
(10~100)m3/h (16~160)m3/h |
450 | ||||
80 | LZB-80 LZB-80F |
(1~10)m3/h (1.6~16)m3/h |
(50~250)m3/h (80~400)m3/h |
500 | ≤0.4 | |||
100 | LZB-100 LZB-100F |
(5~25)m3/h (8~40)m3/h |
(120~600)m3/h (200~1000)m3/h |
Note: Special traffic can be customized.
All stainless steel LZB - () B/BF LZB - () Bo/BoF flanges, floats, guide rods, support plates, and bolts are all made of stainless steel 1Cr18Ni9Ti, model LZB - () B. If 316 is required for the liquid receiving material, the model is LZB - () B0 and it needs to be customized. If stainless steel lined with PTFE is required, the model is LZB - () BF (316 is B0F), which needs to be customized.