PTS -12S Digital Cement Hydration Heat Measurement System (New Version)
PTS -12S Digital Cement Hydration Heat Measurement System (New Version)
Product details

This system was developed by our company in 2006 in accordance with the national standard GB-T 2022-1980 (now updated to GB/T 12959-2008) Cement Hydration Heat Test Method (Direct Method). It is used to automatically record the temperature changes of cement binder in multiple sets of calorimeter, calculate the total accumulated and dissipated heat in the calorimeter, and obtain the hydration heat of cement within 7 days (28 days). The system is fully automated, with dense sampling points and high accuracy, fully replacing old-fashioned manual reading instruments. It can be used in cement plants, scientific research departments, colleges and universities, and construction engineering departments. It is an essential equipment for detecting the hydration heat of cement such as "dam cement", "Portland cement", "slag Portland cement", "fly ash Portland cement", and additives.
The use of this system eliminates the problem of traditional instruments requiring manual duty for reading and large errors in reading recording. Once the sample is installed, manual intervention is no longer needed. The system will automatically control the collection/recording/stopping/analysis/calculation of hydration heat data according to program settings and print hydration heat detection reports. The system uses high-precision temperature sensors to collect the temperature changes of cement in the calorimeter. Multiple sets of calorimeters are installed in a constant temperature circulating water tank with a numerical control device to ensure constant external temperature. The changes in heat values are collected in real time by a multi-channel data acquisition device and transmitted to the computer. The software automatically analyzes the data and displays the hydration heat release curve in real time, and calculates the total heat value within 7 or 28 days.
The system is currentlyChengdu Survey and Design Institute, Central South Survey and Design Institute, Yangtze River Academy of Sciences, Beijing Building Materials Science Research Institute, Gezhouba Testing and Inspection Co., Ltd., Hydropower 7 Bureau Research Institute, Hohai University, Guangzhou University, Lafarge Cement Co., Ltd. (French), Tenglong Cement Co., LtdMany domestic scientific research, experimental, and production units have adopted it.

(Attention to customers: Regarding the current situation where other units mislead customers by using our company's name or claiming to be the first of its kind in China with slogans such as discounted prices, it has been found that many of them counterfeit and steal our company's product network images to sell cement hydration heat measurement systems at low prices online. Currently, multiple customers have reported to our company that they have purchased the counterfeit equipment and found that the actual product appearance does not match the introduction, the design is simple, the operation is inconvenient, and the experimental data is distorted. Our company hereby declares that for details, please refer to our company's website link.)<Company News>One columnhttp://www.wh-pts.com/detail.aspx?node=a3&id=2197(Click on the red font link)


(Attention customers 2: Real photos of the actual usage effect of the new hydration heat related users can be found on our company's website link for details.)Test CaseOne column,http://www.wh-pts.com/content.aspx?node=case(Click on the red font link)

New product features:
--The new water bath adopts a large screen color high brightness LCD controller and a unique tilted front control panel design, which has a beautiful and elegant appearance while effectively preventing water droplets from the tabletop from entering the panel circuit, and avoiding direct collision and compression damage to the LCD panel during transportation.
--The sample holder frame of the new water bath is no longer welded to the inner cavity of the sink, but is made in an integral movable manner, which is convenient for placing the sample at once and for cleaning the bottom of the sink to prevent water rust
--The new water bath can be used as a large volume constant temperature water bath after extracting the support frame of the overall activity basket type sample (achieving the function of one machine for multiple purposes)
--The new water bath has lower noise and more stable operation
--The new water bath offers multiple versions including 6-hole, 8-hole, 10 hole, 12 hole, 16 hole, and 32 hole according to user requirements
--The new software can not only calculate the hydration heat value of 7 days,
According to customer requirements, the function of calculating hydration heat value at any time period has been added, and multiple curves such as hydration heat temperature rise curve, hydration heat total heat output curve, and hydration heat release rate curve can be drawn according to national standards (see the figure below)
--New software can be provided according to customer needsMultiple versions including 7-day standard version and 28 day extended version
Technical parameters of the new system:
Sample channel that can be placed:16 pieces (8 groups), or 6-32 pieces can be made according to user requirements (i.e. 6, 8, 10, 12, 14, 16... 32 pieces)
Water bath volume:280 liters (16 samples)
Sink size:Length, width, and height: 1.65 × 0.8 × 1.2 meters
Water bath: Built in circulating water bath
Sample holder:Improved to a new activity basket style, which can be removed as a whole from the sink
Temperature control accuracy of water bath: 20 ± 0.1 ℃
Temperature control range of water bath:10℃~80We can also design the temperature control range of the water bath according to customer requirements and conduct high and low temperature tests on other materials, such as low temperature -20 ℃ or high temperature 80 ℃
System resolution:0.01℃ (We can provide ultra-high precision 0.0001 ℃ according to customer requirements(Accurate to one ten thousandth), see the attached image at the bottom right
System accuracy: ±0.1℃
System calibration: with calibration sensor zero drift and cold end compensation function
Data acquisition: multi-channel independent data acquisition device (with self calibration function)
Data collection speed:>20 points/s (1/5/10/30/60 minutes optional, can also be set according to user requirements)
Data Interface: StandardRS 232 interface
Data communication: Real time communication with the computer during the experiment, and the computer analysis software can synchronously display the current test data values and the current heat curve graph
Software version:7-day standard version or 28 day extended version, according to customer requirements
Data analysis: Each sample automatically generates an independent database file, which can draw hydration heat rise curve, hydration heat total heat output curve, hydration heat release rate curve, etcThree curves can be used to calculate the total heat value for 7 days or the heat value for any time period.
Compliant with regulations: NationalGB/T 12959-2008 Test Method for Cement Hydration Heat
Standard16The composition of the channel digital direct method cement hydration heat measurement system is shown in the following table:
Serial Number
model
describe
quantity
PTS-12S
Digital Cement Hydration Heat Measurement System (Direct Method)
1
The system includes:
.1
PTS-16
CNC low-temperature circulating constant temperature water bath, capable of simultaneous measurement16 calorimeters
1 unit
.2
PT100
High precision platinum resistance temperature sensor
16 of them
.3
PTS-SPV
16 channel automatic temperature acquisition system
1 piece
.4
PTS-SHR
Hydration heat analysis software
1 set
.5
Lenovo or Same
Class brand
Desktop computer control, computer configuration: Pentium IV not less than3.0MHz processor, 500GB hard drive, DVD drive, 19 LCD display.
1 set
.6
national standard
Five pound wide mouthed thermos with cork stopper (including)4 spare bottles)
20 of them
.7
national standard
Truncated cone cylinder
16 of them
1.8
National standard
Experimental plastic sleeve
32 of them
1.9
Sample sealing kit
1 set
standard configuration16Technical description of channel hydration heat configuration:
1. superLow temperature circulating constant temperature water bath
The low-temperature circulating constant temperature water bath adopts imported compressor refrigeration and built-in magnetic water pump to ensure uniform internal water circulation temperature field and stable performance. The structure is compact and small, and the inner liner is made of all stainless steel, which is clean, beautiful, and corrosion-resistant. Adopting the most advanced automatic control technology in China, it is easy to operate. Digital display microcomputer intelligent PID temperature control LCD panel temperature control, precise temperature control, simple operation.
One CNC low-temperature circulating constant temperature water bath (capable of measuring up to 16 calorimeters simultaneously):
Calorimeter (sample) quantity: 6, 8, 10, 12, 14, 16 according to customer requirements
Sample holder: New basket style, can be removed as a whole from the sink
Temperature control range: 10-50 ℃
Temperature control accuracy: 20 ± 0.1 ℃
Liquid level protection: Add automatic water shortage alarm device
Refrigeration method: Imported compressor refrigeration (independent refrigeration)
Heating method: Heating tube heating (PID automatic control)
Control method: Large screen high brightness LCD digital temperature control (displayed in both Chinese and English)
Working power supply: AC220 ± 10% 50HZ
2.PT100Platinum resistance temperature sensor (with wire)
Range: 0-100 ℃
Resolution: 0.01 ℃
Accuracy: ± 0.1 ℃
3PTS-SPV multi-channel independentData acquisition device
Temperature measurement unit:16 channels (6-16 channels optional), connected to 16 temperature sensors
Temperature resolution:0.01℃
Temperature inspection speed:>20 points/s
System calibration: The acquisition instrument can calibrate each channel sensor and has zero drift calibration and cold end compensation functions
4. PTS-SHRHydration heat analysis software:
Hydration heat analysis software(Optional criteria7-day or 28 day versions
Experimental parameter settings can be made, including automatic collection/stop/recording/analysis/calculation, real-time display of heat release curves for each channel, automatic calculation of water synthesis heat for 1-7 days, and generation of test reports. The interface is simple and friendly, with 16 channels running independently. The real-time acquisition status of each channel is indicated by colors, and functions such as data addition/playback are available. The original database file can be imported into an EXECL file for further analysis,
Multiple data curves can be drawn according to national standards, including hydration heat temperature rise curve, hydration heat total heat output curve, and hydration heat release rate curve.

As shown in the above figure, users can obtain the hydration heat release value at any time period through the hydration heat release curve graph