feature
Better accuracy in detecting ultra-low torque values (1-100 n • cm).
All aluminum constructions. Small size and light weight (about 200 grams).
Application: Material testing machine, testing equipment, etc.
function
Small scale. Lightweight. Control of electrical and hydraulic presses for loads.
Provide top and bottom flange handles. The press has been conveniently installed in terms of position and operation.
A hollow space can be used due to the special measurement of its central hole construction.
Use oil resistant and flexible cables.
Appearance size

Model and capacity/size/etc. (in millimeters)
|
model |
ability |
A |
B |
C |
D |
E |
F |
G |
Natural frequency |
weight |
|
PHC 5KN |
5kN |
40 |
35 |
50 |
1 |
24 |
10 |
2-4-M4 8deep |
8.7 kHz |
0.3 kilogram |
|
PHC 10KN |
10kN |
62 |
55 |
70 |
2 |
44 |
18 |
2-4-M5 8deep |
5.4 kHz |
0.95 kilogram |
|
PHC 20KN |
20kN |
62 |
55 |
70 |
2 |
44 |
18 |
2-4-M5 8deep |
7.5 kHz |
1.0 kilogram |
|
PHC-30KN |
30 Qianniu |
62 |
55 |
70 |
2 |
44 |
18 |
2-4-M5 8deep |
9.2 kHz |
1.0 kilogram |
|
PHC 50KN |
50kN |
62 |
55 |
70 |
2 |
44 |
18 |
2-4-M5 8deep |
11 kHz |
1.0 kilogram |
|
PHC 100KN |
100kN |
62 |
55 |
80 |
2 |
44 |
18 |
2-4-M5 8deep |
12 kHz |
1.3 kilogram |
Note:
*The dimensions in the lower part of the installation are the intersection of Φ FH8 and Φ Bh7 on the top and bottom surfaces. However, please note that the effective size H8 of Φ F is 5 millimeters.
*Considering that the weight in the list does not include the weight of the cables.
Specifications
|
Safe Overload |
120%RC |
|
Rated output |
1mV/V±1% |
|
nonlinear |
0.5%RO |
|
lag |
0.5%RO |
|
reproducibility |
0.3%RO |
|
excitation voltage |
12V(or less) |
|
Safety incentive voltage |
307 |
|
Input tension |
350Ω |
|
Output tension |
350Ω |
|
Range of temperature compensation |
-10 to70 ℃ |
|
Safe temperature range |
-30 to80 ℃ |
|
At ZeroTemp.Effect |
0.01%RO/℃ |
|
Regarding OutputTemp.Effect |
0.03%/℃ |
|
cable |
Φ6mm-4Shielded cable, length:3 m |