Product Introduction
YY (Q) W horizontal fuel/gas heat transfer oil furnace (organic heat transfer furnace) is a new type of heating equipment that uses fuel and gas as heat sources, heat transfer oil as a carrier, and a circulating pump to force the heat carrier to circulate through the circulating oil pump. The heat is transferred to the heating equipment and then returned to the furnace for reheating. The heating surface has a compact structure and is composed of densely arranged circular tubes in the inner, middle, and outer (or inner and outer) directions. The inner tube is a radiating heating surface, while the outer surfaces of the middle and outer tubes and the inner tube form a convective heating surface.
The fuel of YY (Q) W horizontal fuel/gas thermal oil furnace (organic heat carrier furnace) burns and releases heat in the combustion chamber composed of inner coils. After absorbing most of the heat through the radiation heating surface, the high-temperature flue gas enters the convection heating surface and exchanges heat. After leaving the boiler, the air required for boiler combustion is heated in the air preheater, and then sent to the chimney by the induced draft fan through the dust collector and discharged into the atmosphere.
YY (Q) W horizontal fuel/gas thermal oil furnace is mainly used in industries such as chemical and light industry, petrochemical industry, oil and fat decomposition, plastic and rubber, leather industry, textile printing and dyeing, chemical fiber, coating and painting, wood processing, building materials, cement processing, carbon industry, highway transportation, asphalt heating, pharmaceutical industry, atomic energy industry, metal processing, food industry, feed processing, etc.
Performance advantages
(2) The heating surface adopts closely arranged circular tubes, with sufficient arrangement to reduce the surface heat load of the tubes and make the use of heat transfer oil safer;
(3) The diameter and length of the radiation coil are fully adapted to the flame of the matching burner to ensure reliable operation and sufficient cooling of the coil;
(4) The compact structure of the boiler greatly saves the floor space of the boiler room;
(5) Install an air preheater at the tail of a large boiler to improve boiler efficiency;
(6) On the basis of rigorous calculation, the convective heating surface adopts a relatively high and reasonable flue gas flow rate to ensure sufficient heat transfer of the furnace body and high thermal efficiency of the boiler system;
(7) Heating up to 300 ℃ or above, generally working pressure below 1MPa, safe and reliable.
technical parameter
Data model parameters | YY(Q)W-300Y(Q)(25) | YY(Q)W-350Y(Q)(35) | YY(Q)W-600Y(Q)(50) | YY(Q)W-900Y(Q)(75) | YY(Q)W-1200Y(Q)(100) | YY(Q)W-1500Y(Q)(125) | YY(Q)W-1800Y(Q)(150) | YY(Q)W-2400Y(Q)(200) | YY(Q)W-3000Y(Q)(250) | YY(Q)W-3500Y(Q)(300) | YY(Q)W-4000Y(Q)(350) | YY(Q)W-4600Y(Q)(400) | YY(Q)W-6000Y(Q)(500) | YY(Q)W-7100Y(Q)(600) | |
Rated thermal power KW | 300 | 350 | 600 | 900 | 1200 | 1500 | 1800 | 2400 | 3000 | 3500 | 4100 | 4800 | 6000 | 7100 | |
Thermal efficiency% | ≥90 | ||||||||||||||
Design work pressure MPa | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.1 | 1.1 | 1.1 | |
Maximum temperature of the medium ℃ | 320 | ||||||||||||||
Furnace content oil volume m ³ | 0.21 | 0.25 | 0.28 | 0.44 | 0.7 | 1.0 | 1.48 | 2.2 | 3.5 | 4.7 | 5.7 | 7.2 | 8.5 | 9.5 | |
Circulating oil volume m ³/h | 40 | 40 | 60 | 80 | 100 | 100 | 150 | 200 | 200 | 250 | 250 | 250 | 300 | 300 | |
Pipe connection diameter DN | 100 | 100 | 100 | 100 | 125 | 125 | 125 | 150 | 150 | 200 | 200 | 200 | 250 | 250 | |
Complete system installed capacity KW | 17 | 17 | 27 | 40 | 40 | 42 | 45 | 70 | 70 | 85 | 85 | 85 | 100 | 100 | |
Dimensions mm | A | 1016 | 1016 | 1216 | 1416 | 1716 | 1716 | 2000 | 2000 | 2320 | 2500 | 2520 | 3080 | 3220 | 3400 |
L1 | 2050 | 2350 | 3050 | 3290 | 3300 | 3900 | 4400 | 5100 | 5300 | 6000 | 6200 | 6400 | 8000 | 8400 | |
L2 | 2650 | 3000 | 3550 | 3800 | 4065 | 4665 | 4900 | 5900 | 6200 | 6900 | 7200 | 7400 | 9000 | 9400 | |
L3 | 300 | 300 | 250 | 250 | 300 | 300 | 350 | 350 | 350 | 400 | 400 | 450 | 450 | 450 | |
L4 | 500 | 500 | 350 | 370 | 600 | 620 | 400 | 650 | 700 | 700 | 700 | 750 | 750 | 750 | |
H1 | 900 | 900900 | 1000 | 1350 | 1350 | 1500 | 1500 | 1700 | 1700 | 1700 | 1800 | 2000 | 2400 | 2600 | |
H2 | 750 | 750 | 920 | 1010 | 1100 | 1100 | 1200 | 1300 | 1450 | 1450 | 1550 | 1760 | 1800 | 1852 | |
H3 | 700 | 700 | 820 | 930 | 1100 | 1050 | 1250 | 1200 | 1400 | 1400 | 1500 | 1700 | 1800 | 1900 | |
H4 | 650 | 650 | 810 | 900 | 950 | 950 | 1100 | 1100 | 1300 | 1300 | 1400 | 1600 | 1800 | 1890 | |
Total weight of equipment Kg | 1750 | 1950 | 3580 | 4290 | 4900 | 5450 | 6550 | 11400 | 14600 | 16600 | 25000 | 28200 | 30760 | 35340 | |
Basic size mm | 890 | 1190 | 1750 | 1770 | 2000 | 2470 | 2620 | 3700 | 3900 | 4600 | 4820 | 5000 | 6600 | 7000 | |
1150 | 1450 | 2000 | 2100 | 2300 | 2750 | 3450 | 4000 | 4200 | 4900 | 5100 | 5300 | 6900 | 7300 | ||
700 | 700 | 720 | 880 | 1150 | 1150 | 1120 | 1300 | 1500 | 1500 | 1600 | 1800 | 2200 | 2400 | ||
1100 | 1100 | 900 | 1100 | 1550 | 1510 | 1600 | 1700 | 1900 | 1900 | 2000 | 2200 | 2600 | 2500 | ||
450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 |