New Patek dry particle size analyzer HELOS-RDOS from Germany
New Patek dry particle size analyzer HELOS-RDOS from Germany
Product details
parameter |
Indicator |
Particle size range |
0.1-3500 microns (different ranges can be selected to achieve the highest testing accuracy) |
measurement accuracy |
σ<0.04% (error in repeated testing results of a single sample of the same product) σ<0.3% (error in test results of repeated sampling of the same product) |
light source |
5mw helium neon laser, wavelength 632.8nm |
detector |
Fully automatic quasi linear focusing system, multiple detectors, scanning rate: 2000 times/second |
Testing time |
Within 10 seconds (from sample injection to test report output) |
data transmission |
High speed TCP/IP transmission |
obscuration |
Up to 50%* |
Sample size |
Milligram kilogram |
Automatic sampling method |
Vibration groove funnel feeding (conventional material) Rotary brush wheel feeding (for sticky materials) Gas suction feed (materials with low density and easy dispersion) |
Dispersing medium |
Compressed gas (air or inert gas) |
Disperse pressure |
0.1-6Bar (adjusted according to the characteristics of the material) |
Dispersion tube lifespan |
Disperse 2.5 grams of Potland cement each time, at least 100000 times |
data processing |
Fraunhofer or Mie theory |
Result output format |
Standard granularity distribution curve, customer customized format result output, etc |
Supporting documents |
Complete set of instrument operation and maintenance manual, software operation manual in both Chinese and English, original CD of instrument software, system recovery CD, and CD of instrument configuration list |
Operation method |
Software Control Standard Operating Procedure (SOP) |
Power Supply |
AC65-260V, 50/60Hz |
Environmental requirements |
Temperature: 0-40 ℃, humidity ≤ 80%, no condensation |
For large particles, they can be dispersed by the gravity of the particles themselves. New Patek Company can provide a dry gravity dispersion laser particle size analyzer (model: HELOS/GRADIS, Test range: 0.5-8750 micrometers).
Example:
Comparison of dispersion test results of HELOS&RODOS: NdFeB dry wet method using dry laser particle size analyzer:
1. Dry sample testing does not require any dispersants or solvents;
2. Instantaneous dispersion and measurement, fast testing accuracy, high analysis efficiency, and only a few seconds from sample injection to result output;3. Sample sizes ranging from milligrams to kilograms can be tested each time;
4. Easy control of dispersed energy (dispersed pressure can be adjusted between 0.1-6Bar according to material characteristics);
5. A uniquely designed decentralized system with self-cleaning function, which does not require disassembly for cleaning and can continuously test many different materials without causing cross contamination. The system automatically recovers waste materials, which is conducive to environmental protection and reuse;
6. Powerful operating software with multiple report formats to choose from. Test results can be compared on the same interface, and customers can customize report formats, including FDA CFR 21 Part 11 Model;
7. The main body and casing of the instrument are all made of high-quality stainless steel, which is durable and long-lasting