VIP member
NIVELCO Capacitive Level Gauge
NIVELCO capacitance level gauge (capacitance level gauge) is a measuring instrument that uses changes in capacitance to measure the level of dielectri
Product details
-
NIVELCOProduct features of capacitive level gauge:
The hard rod or steel cable probe can be extended up to 20m
There are various forms of electrical levels that are widely used
● No movable parts
● Adopting intrinsic safety design
● Optional HART communication protocol
NIVELCOThe parameters of the capacitive level gauge are as follows:
type
|
Stick
|
Steel cable type
|
Heavy duty steel cable type
|
|||
range |
0.2 ~ 3m |
1 ~ 20m |
||||
Wetware
material
|
Process connection |
Stainless steel (DIN1.4517) |
||||
Probe section |
Partial or complete PFA coated steel |
Partially or completely FEP coated steel cables
|
Partial or complete PE coated steel cable |
|||
Shell material
|
Aluminum or plastic (VALOX412) |
|||||
medium temperature |
-30℃ ~ +200℃ |
-25℃ ~ +80℃ |
||||
Medium pressure |
Max. 6 MPa (60 bar)+20 ℃ (see pressure chart) |
Max 1.6 MPa (16 bar) |
||||
ambient temperature |
-26oC ~ +70oC |
|||||
mechanical strength |
- |
7.7kN |
45kN |
|||
Insulated electrode capacitor |
-600pF/m |
-200pF/m |
-600pF/m
|
|||
output
|
4 ~ 20mA, Two line system (3.9~20.5)
|
|||||
Output voltage/current |
Resistors for measuring voltage: 1v/1mA |
|||||
digital communication |
HART |
|||||
Display module (optional) |
SAP-202 |
|||||
measuring range |
0pF ~ 5nF |
|||||
Minimum transmission range of capacitor |
10pF or 10% |
|||||
Damping time |
3S, 10S or 60S |
|||||
fault indication |
COM and LED flash and output current changes to 3.8 or 22mA |
|||||
Transmission voltage/power |
12 ~ 36V Dcmax.22mA/48 ~ 800mW |
|||||
Maximum Load |
Rtmax=(ut-12v)/ 0.02A |
|||||
accuracy |
± 0.3%
|
|||||
Zero temperature drift |
± 0.02%/oc |
|||||
Electrical connection
|
Cable specifications: PG 16 or M20 x 1.5 Explosion proof cable: 8 15 mm, or . 6 ... 12 mm,
Cross wiring section: 9,5... . 10 mm wiring area n0.5... 1.5 mm2
|
|||||
Process connection |
1”,11/2”Or BSP
|
11/2”NPT or BSP
|
||||
Protection level |
IP67 |
|||||
explosion-proof
grade
|
Standard type |
Class III |
||||
Ex form |
Explosion proof mark: II 1G EEx ia IIB T6 |
|||||
weight
|
2.3kg/0.5m probe |
1.9kg/3m probe |
4.5kg/3m probe |
Online inquiry