Metrohm Swiss Wantong 905/907 Love • Intelligent Series Fully Automatic Potentiometric Titrando (905/907 Titrando)
The 905/907 series is the latest fully automatic potentiometric titrator based on Love Intelligent TM technology launched by Swiss company Wantong in 2009. The intelligent technology of the instrument has reached a new height in titrators. The host, cables, electrodes and other important components are all equipped with built-in chips and data transmission systems, making them the best choice for building an intelligent laboratory.
Technical parameters:
Magic Touch Screen - One Click Quick Start Method
The instrument can be controlled through a computer using PC Control software
Intelligent Connection Cable - A movable measurement input cable that transmits digital information
Intelligent electrode - an automatically recognizable intelligent electrode
GLP - Certified Electrode Testing
Adopting intelligent liquid addition unit
Potentiometric titration, Karl Fischer titration, and STAT titration have multiple functions
Sample processor control
Can be accessed through TiaomoTMSoftware establishes database server
Through TiaomoTMSoftware implementation of parallel titration
Connect LAN and Internet through Lab link
Unique overthinkingTMDosino liquid addition unit can easily achieve quick quantificationTMLiquid Handling Technology
Can accommodate over 800 units with 2 built-in 807 liquid filling unitsTMLiquid dispenser
Supports up to 4 801 magnetic stirrers or 4 804 or 803KF titration tables that can be connected to 802 rod stirrers
4 MSB (Swiss Wantong Serial Port Standard) interfaces
Can connect one sample processor or multiple external devices via USB
Equipped with auxiliary measurement module connection (867pH module or 856 conduction module)
PCMCIA card interface for storage methods, data, password card (user authentication), and backup
Flash memory card with storage capacity for a large number of user methods
Pt 1000 or NTC temperature probe
Differential amplifier (optional)
Optional real-time titration curve display - touch screen (90mm x 120mm color LCD screen) or PC monitor
Resolution: 0.001PH, 0.1mV, 0.1 ℃; Measurement interval: 100ms
Support the use of ion selective electrodes to measure and calculate concentrations
Support automatic confirmation of pH calculation
Certification in compliance with GMP/GLP and FDA regulations
Wireless Bluetooth connection between printer and scale
PH, U/mV, T/℃ measurement interface is completely electrically isolated from the first group
Ipol&Upol - Integrated Program Polarizer
Titration curve evaluation: fixed equivalent point, pK value (HNP), minimum/maximum, inflection point (photometry/conductivity)
User free programming
Method and sample data storage, result storage, database
Multilingual dialogue interface
Compliant with FDA 21 CFR Part 11 requirements
Intelligent liquid addition unit
Intelligent electrode
GLP certified electrode testing
Equipped with detection limit check function
Password settings for protecting access permissions, electronic signatures
Main features:
Adopting the patent of Swiss Wantong, DosisTMLiquid addition unit
Duosi's patented designTMThe liquid addition unit can be directly installed on the top of the reagent bottle, which means that the liquid addition unit does not require additional workbench space. Based on a suitable interface adapter, the dispensing unit can be directly installed on any specification of reagent bottle. DuosiTMThe system adopts the latest electronic and micro mechanical technologies. The replacement of the liquid addition unit can be completed in a very short time. The design of the transparent shell allows for clear visibility of any air bubbles that may exist inside the burette, facilitating timely elimination, while also allowing for real-time observation of the position of the driving valve. The flushing and preparation of the liquid addition unit are fully automated and do not require manual disassembly for cleaning.
Both 905/907 support DET dynamic titration, MET equivalent titration, and SET set titration
The 905 editable method supports KF volumetric Karl Fischer titration and STAT constant potential titration
The 907 type built-in method supports KF volumetric Karl Fischer titration and STAT constant potential titration