VIP member
Medium and low temperature screw refrigeration unit (dual head)
Note:
Product details
project
|
unit
|
model
|
||||||||||||||||
RXG150B
|
RXG195B
|
RXG215B
|
RXG259B
|
RXG290B
|
RXG335B
|
RXG387B
|
RXG427B
|
RXG460B
|
RXG547B
|
RXG578B
|
RXG640B
|
RXG681B
|
RXG713B
|
RXG828B
|
RXG910B
|
|||
The required temperature and cooling capacity of the refrigerant
|
-5℃~-10℃
|
kW
|
146.4
|
190.5
|
210.7
|
253.8
|
284.4
|
328.1
|
379.5
|
418.1
|
451.2
|
536.3
|
566.2
|
626.4
|
667.8
|
698.5
|
811.6
|
891.4
|
-15℃~-20℃
|
98.8
|
128.6
|
142.1
|
171.3
|
191.9
|
221.3
|
256.0
|
282.0
|
304.4
|
361.8
|
382.0
|
422.8
|
450.6
|
471.4
|
547.6
|
601.3
|
||
-25℃~-30℃
|
61.9
|
80.8
|
89.2
|
107.4
|
120.5
|
139.0
|
160.7
|
177.0
|
191.1
|
227.2
|
239.9
|
265.4
|
282.8
|
295.8
|
343.8
|
377.5
|
||
power supply
|
|
3P 380V 50Hz
|
||||||||||||||||
compressor
|
form
|
|
Advanced semi enclosed twin-screw type
|
|||||||||||||||
Operating power
|
kw
|
70.4
|
89.4
|
100.0
|
117.0
|
131.5
|
149.7
|
173.1
|
188.4
|
206.2
|
243.6
|
257.2
|
286.0
|
303.4
|
319.5
|
368.1
|
404.2
|
|
refrigerant
|
|
R404a
|
||||||||||||||||
Energy control
|
%
|
0~25%~50%~75%~100%
|
||||||||||||||||
evaporator
|
type
|
|
Horizontal shell and tube high-efficiency heat exchanger
|
|||||||||||||||
Refrigerant flow rate
|
m3/h
|
46.0
|
59.8
|
66.2
|
79.7
|
89.3
|
103.0
|
119.2
|
131.3
|
141.7
|
168.4
|
177.8
|
196.7
|
209.7
|
219.4
|
254.9
|
279.9
|
|
Water pipe interface
|
mm
|
DN100
|
DN100
|
DN100
|
DN125
|
DN125
|
DN125
|
DN125
|
DN125
|
DN125
|
DN150
|
DN150
|
DN150
|
DN150
|
DN150
|
DN200
|
DN200
|
|
condenser
|
type
|
|
Horizontal shell and tube high-efficiency heat exchanger
|
|||||||||||||||
discharge
|
m3/h
|
37.2
|
48.0
|
53.3
|
63.6
|
71.3
|
81.9
|
94.7
|
104.0
|
112.7
|
133.7
|
141.2
|
156.4
|
166.5
|
174.5
|
202.2
|
222.1
|
|
Water pipe interface
|
mm
|
DN100
|
DN100
|
DN100
|
DN125
|
DN100*2
|
DN100*2
|
DN100*2
|
DN100*2
|
DN100*2
|
DN125*2
|
DN125*2
|
DN125*2
|
DN125*2
|
DN125*2
|
DN150*2
|
DN150*2
|
|
Refrigerant control
|
expansion valve
|
|
Temperature sensitive external pressure equalization thermal expansion valve
|
DN25
|
DN25
|
|||||||||||||
Safety protection device
|
|
|
High and low voltage protection, anti freezing, anti heat, dual protection, safety valve, overload protection, phase loss, reverse phase, undervoltage, overvoltage, water flow protection, etc
|
|
|
|||||||||||||
External dimensions
|
Long (L)
|
mm
|
2870
|
3240
|
3400
|
3600
|
3600
|
3850
|
4000
|
4000
|
3900
|
4150
|
4150
|
4380
|
4250
|
4500
|
4800
|
4950
|
Width (W)
|
mm
|
1100
|
1100
|
1150
|
1200
|
1200
|
1200
|
1250
|
1250
|
1300
|
1350
|
1400
|
1450
|
1500
|
1550
|
1600
|
1600
|
|
High (H)
|
mm
|
1600
|
1650
|
1700
|
1750
|
1750
|
1800
|
1800
|
1800
|
1850
|
1850
|
1900
|
1950
|
1950
|
2200
|
2400
|
2500
|
|
weight
|
net weight
|
kg
|
1805
|
1900
|
2090
|
2565
|
2850
|
3002
|
3268
|
3515
|
4085
|
4560
|
5035
|
5510
|
5890
|
6650
|
7220
|
7980
|
Operating weight
|
kg
|
2076
|
2090
|
2299
|
2822
|
3135
|
3302
|
3595
|
3867
|
4494
|
5016
|
5539
|
6061
|
6479
|
7315
|
7942
|
8778
|
Note:
1. Refrigeration condition: The refrigerant is a 60% ethylene glycol aqueous solution; The inlet/outlet temperature of the cooling water is 32/37 ℃.
2. Scope of work: The outlet temperature of the cooling water is between 22 ℃ and 37 ℃, and the inlet temperature difference of the cooling water is between 3.5 ℃ and 10 ℃; The outlet temperature of the frozen liquid is -5 ℃ to -30 ℃, and the temperature difference between the inlet and outlet of the frozen liquid is 2.5 ℃ to 5 ℃.
3、This series of units can all be equipped with a heat recovery system (hot water temperature 35 ℃~60 ℃)
4、At the same time, our company can customize various anti-corrosion and explosion-proof units according to the specific needs of customers.
5、If there are any changes to the above specifications without prior notice, this will help our company to bring the latest technological achievements to customers at any time.
Online inquiry