Material Purification Test Chamber
Material Purification Test Chamber
Product details


Product Overview:

The material purification testing chamber meets the latest standardsJC/T1074-2021The testing requirements of the "Purification Performance of Coating Materials for Indoor Air Purification Function" climate and environmental testing standards strictly follow the technical parameters such as temperature, humidity, background cleanliness, desorption of pollutants in the cabin, closed-loop circulation between the gas generator and the cabin, test light source, light intensity, and sample placement angle for sample preparation.

This test chamber simulates the climate conditions in the indoor environment and meets the spatial environmental characteristics of adsorption and purification of pollutants in the air by coatings with adsorption and purification functions.


User value of material purification testing chamber:

2.1Determine the influence of sample materials on the adsorption capacity and adsorption characteristics of formaldehyde (toluene) in the air during environmental variable processes

2.2Classification of materials based on their adsorption characteristics for formaldehyde (toluene) according to the sample material

2.3Verification of air quality characteristics of formaldehyde (toluene) adsorption in indoor air based on data collected during the research and testing process of sample materials

2.4Evaluation of Sustainable Duration and Efficiency Decay of Sample Materials after Adsorption of Formaldehyde (Toluene) in Natural Environment

2.5Predicting and evaluating the quality of indoor air by analyzing the adsorption capacity of sample materials based on detection data

Meet the standards:

JC/T1074-2021Purification Performance of Coating Materials for Indoor Air Purification Function

Suitable for normative reference documents and standards:

GB/T 3186Sampling of raw materials for paints, varnishes, and paints and varnishes,ISO 15528:2000

GB/T 9271—2008Standard test panels for paints and varnishes

GB/T 16129Standard method for hygiene inspection of formaldehyde in the atmosphere of residential areas - spectrophotometric method

GB/T 18883Indoor Air Quality Standards


Product Technical Features:

4.1 control module

1usePLC+The touch screen human-machine interface features a one click intelligent operation control mode, making daily operations easy to manage and human-machine exchange convenient. It is perfectly designed for human operation positions.

2After the experiment is completed, the machine will automatically stop and save the operating data (the environmental parameters inside the climate chamber have been set at the factory, and the standard test parameters do not need to be set separately).

4.2 In cabinTEST

1Temperature and humidity control

usePLCAs the core control unit, it has high reliability and strong anti-interference ability. During the testing process, it realizes automatic constant temperature control of the cabin temperature and absolute humidity control of humidity sealing, effectively maintaining the temperature inside the climate chamber/The humidity remains constant at23℃Relative humidity50%The scope.

2) Heating and cooling system

The balanced heat source uses the compression heat of the refrigeration system for heat exchange, reducing the load of electric thermal balance heat exchange, ensuring stable performance, and reducing operating energy consumption.

The refrigeration unit adopts imported fully enclosed compressors, and the cooling method adopts air cooling. It has low operating noise, high reliability, and simple on-site installation and commissioning work for customers.

3)gas generatormodule

Adopting an adjustable constant temperature gas generator for gasification injection of reagents (formaldehyde, toluene), the injection method should form a closed-loop loop with the environmental chamber, which can easily achieve precise control of formaldehyde volatilization temperature and volatilization rate.

4)Light source control module

The intensity of LED and UV light sources can be adjusted, and can be combined with irradiance sensors to achieve closed-loop PID regulation.

5) Air exchange method

Use clean air replacement for secondary treatment.

6) Bottom detachment method inside the test chamber

The clean air used to desorb the background adopts a forced pressure pump in type, and the equipment has overpressure alarm and displacement flow regulation functions.

4.3 Operation monitoring module

1) Real time monitoring and data storage of temperature, humidity, and various parameters.

2) The historical data and curves of parameters at each point during the experiment can be queried and viewed in real time.

3) Data can be downloaded from a USB drive and saved to a computer for analysis, editing, and viewing of archives.


Technical parameters:

name

Material Purification Testing Chamber

model

AIBEVS 8211

volume

1m³±0.2%

temperature control

Temperature control range

+20℃~﹢40℃

temperature resolution

0.1℃

temperature fluctuation

≤±0.2℃,Stability time less than 40 minutes

Temperature uniformity

≤1.5℃

Humidity control

Humidity control range

35%~70% RH (temperature+20~+40 ℃)

Humidity fluctuation

Environmental preparation process: ≤± 1.5% RH, from the beginning to the end of the experiment: 240 hours: ≤± 4% RH, with a stabilization time of less than 70 minutes

humidityresolution

0.1%RH

Cooling of refrigeration unit

Cooling method

forced air cooling

Light source control

UV light source

Power 20w, wavelength 365nm

Irradiance:

The arithmetic mean of irradiance at the center position of each template shall not be less than 50-60mw/cm

Visible light source

1 unit, power 16w, color temperature 6500K white light

Irradiance:

The arithmetic mean of the illuminance of the LED light source at the center position of each template shall not be less than 1000-1200Lx

Mixing inside the cabin

Mixing fan

Multi blade axial fan with blade radius of 710cm, adjustable speed>5r/s

Heat exchange method inside the cabin

Cold wall heat exchange

Traditional air circulation with air ducts and fins is prohibited in the cabin to reduce the flow surface of air ducts and heat exchange fins, facilitating clean detachment of the background inside the cabin

Air flow meter

Digital Flow Meter

Range 0-50L/min, accuracy level 0.5

Glass rotor flowmeter

Range of 10-60L/h, accuracy not less than level 2.5;

gas generator

The gas flow rate can be adjusted from 1L/min to 4L/min,Reagent vessel vaporization temperature Adjustable from 30 ℃ to 60 ℃, with a chamber volume of ≤ 100cm ³

Air tightness

100pa holding pressure for 24 hours residual pressure>5pa (@ temperature (25 ± 0.5) ℃, relative humidity (50 ± 5)%,)

Reagent injection method

Gas generator and test chamber closed-loop cycle

Control range of cabin depressurization

1~10Pa adjustable control accuracy ± 5Pa

Cabin pressure monitoring

Analog digital display micro pressure sensor, touch screen online cabin pressure display stable time

24-hour empty reagent decay rate

Formaldehyde decay rate ≤ 20%; Toluene attenuation rate ≤ 18% (@ temperature (25 ± 0.5) ℃, relative humidity (50 ± 5)%,)

Desorption air exchange rate

1-3 times/hour (adjustable)

Equipment operating noise

Test cabin ≤ 60db (A-level)

Bottom concentration of formaldehyde and toluene in the empty cabin

<0.006mg/m³

Sustainable operation of equipment

>30 days

Factory settings

Cabin temperature/humidity 23 ℃/50% RH, air exchange rate 1 time/h, cabin pressure 10Pa

Product external dimensions

930 × 1710 × 1715 mm (width x depth x height)

Cabin dimensions

800 × 1250 × 1000mm (width x depth x height)

Using environmental and working condition parameters:

6.1 Requirements for moving equipment into the usage site

Passage and elevator

Height and width of channels and doors: above 2000mm

When using an elevator, in addition to meeting the above dimensions, the following requirements must also be met

Depth: above 3000mm; Load capacity: above 1000Kg

If the above conditions cannot be met, please be sure to contact our company in advance.

6.2 Equipment installation requirements:

power supply

Power Supply: AC220V φ150Hz

Maximum load capacity: 3.2KW

Maximum current: 15A

Power switch capacity: 20A

water supply

Please use purified water or distilled water with a conductivity of ≤ 10 μ s/cm

Condensate drainage

Drainage pipe diameter ≥ DN25,

The inclination angle is greater than 5 °, and the height difference below the drainage outlet is not less than 5cm


Ordering information:

AIBEVS 8211 Material Purification Test Chamber

AIBEVS 8211/P/001 Formaldehyde generator

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!