MULP-8c Multi Parameter Water Quality Tester
Equipped with DIS-16B (or optional DIS-20B/25B/36B) digestion analyzer;
Equipped with printing and USB data upload;
Adopting a 5-inch large screen color touch screen with Chinese and English display;
Equipped with one click recovery function;
Automatic wavelength selection.
The multi parameter water quality analyzer uses a single wavelength of light to pass through the test sample, and according to Lambert Beer's law, calculates the concentration value of a substance contained in the sample by measuring the absorbance value.
【 Host 】 | |
Customizable products can be selected from the following options: | 340,420,440,470,520,540,560,610,630,660,680,700nm |
Accuracy: | Maximum absorbance error: 0.005; The maximum error of measurement results is generally 5%, with a few exceptions of 10% |
Absorption range: | -2.000~2.000 |
Power Supply: | AC220V(165V~240V), 30W |
Instrument size: | 400x310x158mm |
Instrument weight: | 5kg |
Work environment: | Temperature: 10-35 ℃; Humidity not exceeding 90% |
The measurement wavelength can be selected. The multi parameter water quality analyzer can take backup measures for user calibrated curves and data records, and can perform recovery operations in case of accidental loss. The instrument comes with various security measures, and can be set to power on and input passwords for system settings. The instrument comes with a calibration function that performs self calibration during operation, effectively eliminating drift errors caused by long-term use. The instrument adopts a 5-inch large screen color touch screen operation, with a user-friendly interface. The light intensity can be adjusted, divided into 16 levels and set arbitrarily, which can effectively solve the problem of measurement range expansion caused by the strength of the signal. |
![]() In addition to the factory curve, users can add and calibrate curves themselves, and store them in the instrument. It is possible to query the curve, in addition to querying the curve equation, it is also possible to query the standard value and corresponding absorbance of each standard substance during calibration, as well as the calibration time and calibration personnel number, fully reproducing the state during calibration. Type C can store 300 curves, while Type D can store 3500 curves; Type C can store 1000 records, while Type D can store 100000 records. Optical system optimization upgrade (D-type), the system is more stable during measurement, with better accuracy and stability. |
![]() When recording queries, single item printing or page printing can be performed. The system has bilingual functionality and can switch between Chinese and English. |
![]() The instrument measurement method can choose the straight line method or the line method. Choosing the line method can achieve more accurate measurement of some parameters with poor linearity. It has a one click recovery function, which can achieve one click recovery when the factory curve and user curve data records are lost due to accidents. |