basic descriptionBasic description-Heavenly Shield-
The MDI series products are customized lightning protection products for high-definition network cameras (with pan tilt control), protecting camera power, network and other circuits from the effects of lightning electromagnetic pulses, induced overvoltages, and operational overvoltages. They are widely used in public security, traffic monitoring and other fields. This series of products has the characteristics of high integration, low insertion loss, low residual voltage, and easy installation, and has good lightning protection effect.
Application scenariosApplication scene-Heavenly Shield-
-
01Mainly used for the protection of monitoring equipment (power supply, gimbal, camera) in monitoring systems;
02Widely used in bank monitoring systems
03High definition monitoring equipment for schools, enterprises, road safety protection, etc.

Technical Parametertechnical parameter-Heavenly Shield-
model |
MDI-2-12 |
MDI-3-24 |
MDI-3-220 |
||
network/Control some electrical parameters |
|||||
working voltageUc |
12V |
||||
Nominal discharge currentIn |
3kA(8/20μs) |
||||
Maximum flow capacityImax |
5kA(8/20μs) |
||||
protection levelUp |
40V |
||||
transfer rateVs |
Control 10Mbps; Network: 1000Mbps |
||||
response timeTa |
1ns |
||||
bit error rate |
<10-12 |
||||
Joint form |
Network: RJ45; Power supply and control: crimping type |
||||
Electrical parameters of the power supply section |
|||||
working voltageUn |
12VDC |
24VAC |
220VAC |
||
Maximum Continuous Operating Voltage |
15VDC |
30VAC |
275VAC |
||
Nominal discharge currentIn |
5kA(8/20μs) |
||||
Maximum flow capacityImax |
10kA(8/20μs) |
||||
Protection levelUp |
60V |
100V |
900V |
||
Joint form |
Crimping type |
||||
External dimensions |
88 * 68 * 40mm (excluding terminals) 88 * 68 * 38mm (excluding terminals and rails) |
||||
Protection level |
IP20 |
installation diagraminstallation diagram-Heavenly Shield-
-
-
1. The lightning arrester is connected in series between the protected equipment and the signal channel.
2. The input terminal (IN) of the lightning arrester is connected to the signal channel, and the output terminal (OUT) is connected to the protected equipment and cannot be reversed.
3. Connect the grounding wire of the lightning arrester reliably to the grounding bar of the lightning protection system.
4. This product does not require special maintenance. When there is suspicion of a malfunction in the lightning arrester during system operation, it can be removed and checked again. If the system returns to normal after being restored to its pre use state, it indicates that the lightning arrester has been damaged and must be replaced immediately.