Shanghai Neway Electronic Technology Co., Ltd
Home>Products>Low porosity and low-permeability rock sample testing instrument, rock core analyzer, nuclear magnetic resonance rock fragment pore testing instrument
Low porosity and low-permeability rock sample testing instrument, rock core analyzer, nuclear magnetic resonance rock fragment pore testing instrument
The MicroMR series products (low porosity and low permeability rock sample testing instrument, core analyzer, nuclear magnetic resonance rock debris p
Product details

Product Introduction:

MicroMR series small core magnetic core analyzer(Low porosity and low-permeability rock sample testing instrument, rock core analyzer, nuclear magnetic resonance rock fragment pore testing instrument)There are three series of nuclear magnetic resonance core analyzers, namely 2MHz, 5MHz, and 12MHz. This series of nuclear magnetic resonance products is carefully developed for the detection needs of different characteristic rock samples, providing the most professional and matching analysis solutions for the field of petroleum core testing. After years of unremitting efforts by Neway, three products in MicroMR (2MHz, 5MHz, 12MHz) can also be upgraded with diffusion function to become multidimensional nuclear magnetic resonance core analyzers, bringing great convenience to practical applications.
MicroMR series products(Low porosity and low-permeability rock sample testing instrument, rock core analyzer, nuclear magnetic resonance rock fragment pore testing instrument)Compact in size and structure, it is a desktop nuclear magnetic resonance core analyzer with horizontal capabilities; The MicroMR series nuclear magnetic resonance core analyzer can meet the requirements of porosity, permeability, saturation, movable fluid saturation, bound fluid saturation and other related analysis and testing in the field of petroleum exploration. The measurement results are objective and true, with high accuracy, good repeatability, stable instrument performance, and high cost-effectiveness. (

Application solution:

1. 2/5MHz nuclear magnetic resonance analyzer: conventional core pore structure and fluid saturation;
2. 12MHz nuclear magnetic resonance analyzer, high-performance short TE:
1) Conventional core pore structure and fluid saturation;
2) Pore structure and fluid saturation of unconventional rock cores (tight rock cores, mudstone, shale);
3) Oil and water content distribution and oil-water content testing of medium and large-sized rock samples;

Application example one: Glass bead pore model testing (T2 relaxation spectrum analysis at different saturation levels)

Application Example 2: T2 Graph and Pore Throat Distribution

Note: If there are any changes in the appearance of the instrument, the data formula shall prevail