VIP member
Large walk-in high and low temperature laboratory
Application of large walk-in high and low temperature laboratory products: Large walk-in high and low temperature laboratories are mainly used for ada
Product details




| Aircraft instrument model | ZH-DTH-4500 (A~D ) |
ZH-DTH-6000 (A~D ) |
ZH-DTH-8000 (A~D ) |
ZH-DTH-10000 (A~D ) |
| Internal dimensions W × H × D (cm) | 200*150*150 | 200*200*150 | 200*200*200 | 250*200*200 |
| Room material | Polyurethane foam plastic composite assembly board (outer wall is color steel plate, inner wall is stainless steel plate) | |||
| temperature range | Maximum temperature: 120 ℃, 85 ℃; Minimum temperature: 0 ℃, -20 ℃, -40 ℃, -50 ℃ | |||
| humidity range | 20%~95%RH | |||
| Temperature and humidity stability | ≤±0.5℃/; ≤±2.5%RH. | |||
| Uniformity of temperature and humidity | ≤±2℃/; ≤±5%RH. | |||
| Cooling method | Mechanical compression binary cascade refrigeration | |||
| refrigerator | Compressor (using French Taikang fully enclosed compressor or German Bitzer semi enclosed compressor) | |||
| cooling method | Water cooling (optional air-cooled type for small systems) | |||
| heater | High quality nickel chromium alloy heater | |||
| humidifier | Stainless steel sheathed heater | |||
| Cooling circulating water | Cooling water pressure: 0.1~0.3Mpa; Water temperature: ≤ 25 ℃ | |||
| blower | centrifugal fan | |||
| temperature sensor | PT100 platinum resistor | |||
| Door observation window | Coated heat film insulated glass | |||
| controller | High quality 7-inch true color touch screen control system, capable of program setting function, USB/R232 interface | |||
| safety device | Overtemperature protection, leakage protection, dry burning protection (humidification system), water shortage protection, fan overload protection, compressor overpressure, overload, overcurrent protection, phase sequence protection, fuse | |||
| Standard device | Electric heating membrane insulated glass observation window, indoor lighting, accumulation timer | |||
| Optional parts | Add a room door (with observation window), which can be installed on the laboratory wall, operating hole, handling inclined platform, floor reinforcement plate, floor protection, rubber pad for floor protection, cable hole (opening size according to customer requirements) | |||
| We can undertake the design and manufacturing of various large-scale non-standard environmental testing laboratories according to the specific requirements of users | ||||
Online inquiry