Laboratory Ultra Pure Water Series
Laboratory ultrapure water machine is a laboratory water purification equipment that removes all solid impurities, salt ions, bacteria and viruses fro
Product details
Aquaplore3 is a system designed specifically for users with small usage but strict production and quality requirements. Automatically monitor and trace your water production process and maintenance work to ensure consistent and compliant quality of your ultrapure water. Featuring a variety of clever and intelligent designs, we assist you in quickly completing complex calibration and correction tasks, saving unnecessary manpower and time, allowing you to focus on more important research work. Now you no longer have to compromise your management work due to resource limitations, and can easily have laboratory ultrapure water with compliant quality.
| Dimensions and Weight | |||
| size | H x W x D; 625 x 410 x 470 mm | ||
| packing weight | 40kg | ||
| Water inlet requirements | |||
| water source | Tap water inflow | ||
| traffic | ≥ 50 L/h | ||
| Conductivity (25 ° C) | < 2000 μS/cm | ||
| pressure | 1-5 Kg | ||
| temperature | 5-35 °C | ||
| free chlorine | < 1 ppm | ||
| PH value | 6.5-8.5 | ||
| Total hardness (as CaCO)3Calculation) | <450ppm | ||
| Electricity requirements | |||
| Electricity input | 100-240 VAC,50-60 Hz | ||
| system voltage | 24V DC | ||
| System power | 221W(max) | ||
| Noise level | < 50 dB | ||
QualitybyDesign
Intelligent system design makes your pure water compliance faster and simpler
Patented Waterway Integration Process (P.I.M.)
The patented waterway integration process provides a unique and compact standard structure, integrating all purification units and control components. Thoroughly disinfect the entire circulation pipeline from the inlet to the outlet, avoiding the risk of contamination caused by incomplete disinfection operations.
Plug and play purification modules and control components enable more efficient on-site system maintenance operations such as sampling, validation, calibration, maintenance, and cleaning, providing low-cost and time-saving solutions.
Standardized waterways effectively avoid human errors during maintenance operations, ensuring system integrity and easier replacement of consumables, making after-sales service more efficient and economical.
Intelligent consumables management
Unlike traditional consumables replacement calculation methods based on calendar days, “SmartAngel ®” Through complete automatic monitoring and self diagnosis, track the actual consumption of consumables based on different purification capacity indicators, plan the optimal replacement time, and meet the compliance requirements of the system.
You can directly check the operating status of each purification unit on the screen at any time, and the system will also notify consumables of expiration in advance according to the set purification capacity indicators, allowing you to prepare in advance.
Based on your data, easily set up customized preventive maintenance programs to make your consumables replacement more reasonable and economical.
Intelligent water intake method
Small water volume intelligent and precise water intake: with an error of less than 2ml, there is no need to use traditional measuring cylinders or cups for water intake. Eliminate the need for you to simultaneously pay attention to the scale of the measuring cup and control the flow rate when taking water, making it easy to obtain the amount of water you need. No need to purchase expensive split type water intake devices.
Intelligent multiple water intake of the same volume: The commonly used water intake volume can be set arbitrarily in milliliters. The patented 'SmartAngel @' can store and remember for you. Therefore, you can quickly operate the same volume of water intake multiple times to avoid repetitive work. Fast and efficient.
Intelligent water intake with large water volume: Automated water intake eliminates your waiting time.
• Appointment water collection mode: You can pre-set the automatic water collection time and amount. The next day, when you need water, the system will prepare the necessary experimental water for you, so you don't have to wait for time.
| Product Series | A3-05-05/10-BE | A3-10-05/10-BE | A3-20-05/10-BE |
| water quality parameters | |||
| Ultra pure water resistivity (25 ° C) | 18.2MΩ•cm | 18.2MΩ•cm | 18.2MΩ•cm |
| Pure water conductivity * (25 ° C) | 1-5 μS/cm | 1-5 μS/cm | 1-5 μS/cm |
| Total Organic Carbon (TOC) * * (treated with DP-RO) | < 1-3 ppb | < 1-3 ppb | < 1-3 ppb |
| bacteria | < 0.1 CFU/ml | < 0.1 CFU/ml | < 0.1 CFU/ml |
| bacterial endotoxin | < 0.001 EU/ml | < 0.001 EU/ml | < 0.001 EU/ml |
| Particulate matter (>0.2um) | <1/ml | <1/ml | <1/ml |
| Inorganic ion removal rate | ≥99.5% | ≥99.5% | ≥99.5% |
| heavy metal ions | ≤ 0.1 ppb | ≤ 0.1 ppb | ≤ 0.1 ppb |
| Silicon removal rate | > 99% | > 99% | > 99% |
| Water quantity parameters | |||
| Secondary reverse osmosis water production (25 ° C) | 5L | 10L | 20L |
| Water intake for pure water/ultrapure water respectively | 10ml-99L, The value can be set arbitrarily, with an accuracy of ± 2ml within 500ml and ± 1% above 500ml | ||
| Water intake flow rate | 1-2L/min | ||
| Ultra pure aquatic water quantity*** | 5/10T | 5/10T | 5/10T |
| Water utilization rate | 60-80% | 60-80% | 60-80% |
| Purification technology | |||
| Tap Water Pre treatment | yes | yes | yes |
| Reverse osmosis (DP-RO) | yes | yes | yes |
| Ultra purification column | yes | yes | yes |
| Photo oxidation | 185/254nm UV | 185/254nm UV | 185/254nm UV |
| Ultrafiltration column | 6KD | 6KD | 6KD |
| 0.2um Terminal Filter (UF) | yes | yes | yes |
| *Under the condition of general municipal water supply and conductivity<1000 μ S/cm | |||
| **Under the condition of general municipal water supply and raw water TOC<1000ppb | |||
| ***Different depending on the inflow situation | |||
Online inquiry