CanadaSolinst launches LTC Levelogger EDGEOnce again, the standards for underground recorders have been raised. The shell is made of fully corrosion-resistant titanium alloy ceramic material, greatly improving the reliability and long-term stability of the product. Three internal sensors simultaneously measure water level, temperature, and conductivity, and store them in the instrument's memory, which can be downloaded to the computer for processing at any time.LTCIt can be widely applied to emission monitoring, landfill treatment monitoring, as well as water storage and land restoration projects, salinization projects, seawater erosion projects, etc.
Advantages of LTC EDGE
◎titanium alloyceramicscasing
Six water level range options, 5, 10, 20, 30, 100, 200 meters, with an accuracy of 0.05%;The measurement units include:cm, m, ft, psi, kPa, bar
High precision temperature sensor with an accuracy of 0.05 ℃ and a resolution of 0.003 ℃
◎ Three year warranty
◎ Conductivity range100,000 μS/cm, Resolution±0.1 μS/cm
◎ Can be paired with Bluetooth communication module, and can be operated on mobile phones or tablets in the field
Application areas: Monitoring of aquifer rechargeMonitoring of seawater intrusionTheMonitor wastewater (illegal) discharge, monitor garbage disposal sitesMonitoring the quality of groundwater or surface water
Technical parameters of sensors
water level sensor
Hastelloy diffused silicon
Water level range
5, 10, 20, 30, 100,and200 m
Water level accuracy
±0.05% FS
Water level measurement unit
cm, m, ft, psi, kPa, bar (ºC, ºF)
Temperature compensation range
0ºC to 50ºC(Automatic temperature compensation)
temperature sensor
Platinum resistance temperature sensor(RTD)
accuracy
±0.05ºC
resolution
0.003ºC
TriE Conductivity Sensor
Four platinum electrodes
measuring range
0 to 100,000 μS/cm
calibrated range
50 to 80,000 μS/cm
accuracy
±1% > 30,000 μS/cm;
±2% 500 - 30,000 μS/cm;
±30μS < 500 μS/cm
resolution
±0.1 μS/cm
Temperature compensation range
0ºC to 50ºC
Instrument technical parameters
BATTERY LIFE
8 year(Monitor a set of data every 5 minutes)
Clock accuracy:
±1minute/year(-20ºC to 80ºC)
operation temperature
-20ºC to 80ºC
Memory:
3*27,000group
Storage mode
Solid state full mode perhaps Cycle Mode
Communication method
optical communication: USB, RS-232, SDI-12
size
7/8' x 7.5' (22 mm x 190 mm)
weight
7.05 oz. (200 grams)
Anti corrosion shell material
Titanium alloy ceramics
Working mode
Fixed monitoring
Set the frequency according to the amplitude
pumping test
Monitoring frequency
2 seconds to 99 hours
Pressure compensation method
Paired with barometer compensation
Origin manufacturer:CanadaSolinst