- LMIX series
- Marked pulse
- Resolution=0025 mm (when divided by four times);
0.1 mm (single frequency division)
- Repetitive accuracy+/-0.025 mm
- Small sensor reading head with built-in reading electronic components
- Square wave signal speed ratio output
LMIX2 Technical Data
resolving power
|
When dividing by one, 0.1 mm; 0.025 mm at quadruple division |
Repetitive accuracy |
+/- 0.025 mm |
System accuracy µ m at 20 ° C |
+/-(25+20 x L) (L=length, meters) |
Sensor/magnetic ruler distance |
Max 2.0 mm |
Shell |
Die cast zinc alloy |
Protection level |
IP 67 |
Operating temperature |
-10 ... + 70 ° C (-25...+85 ° C as required) |
Storage temperature |
-25 ... + 85 °C |
Output current |
Maximum 20 mA per band |
Marking pulse (every 5 mm) |
The cycle time depends on the operating speed |
When the voltage is 5 VDC/5 V-TTL line driver output | |
Error/working voltage |
+/-2.5%, standing wave coefficient<50 mV |
Current consumption |
Maximum 200 mA |
output frequency |
40 kHz (per band) |
running speed |
Max 4.0 meters per second |
Maximum cable length |
10 m |
When the working voltage is 10-30 VDC/5 V-TTL line driver output | |
Error/working voltage |
Stable, with a maximum standing wave coefficient of 5% |
Current consumption |
Maximum 150 mA |
output frequency |
40 kHz (per band) |
running speed |
Maximum 4 meters per second |
Maximum cable length |
50 m |
Working voltage 10-30 VDC/10-30 VDC output | |
Error/working voltage |
Stable, with a maximum standing wave coefficient of 5% |
Current consumption |
Maximum 150 mA |
output frequency |
Under ideal reading conditions, 40 kHz (per band) |
running speed |
Under ideal circumstances of dereliction of duty, the maximum speed is 4 meters per second |
Maximum cable length |
30 m |
LMIX3 Technical Data
working voltage |
10-30 VDC stable, with a maximum standing wave coefficient of 5%; 5 VDC+/-2.5%, standing wave coefficient<50mV |
Current consumption |
Maximum 150 mA (voltage 10-30 V); Maximum 200 mA (voltage 5 VDC) |
Output terminal |
Push pull type, reverse signal anti continuous short circuit, band A/A ', B /B‘, Z /Z‘ |
signal level |
10-30 V or 5 V-TTL |
Flag pulse |
Every 5 mm |
Repetitive accuracy |
+/- 0.025 mm |
System accuracy at 20 ° C, μ m: |
+/-(25+20 x L) (L=measured length, meters) |
resolving power |
0.1 mm (single frequency), 0.025 mm (4th harmonic) |
speed |
Maximum 4 m/s -5V/TTL; Maximum 4 m/s -10-30V/HTL (at optimal reading) |
output frequency |
40 kHz each/band A/B/A '/B‘ |
Measure length |
Maximum 32.0 meters |
Sensor/magnetic ruler distance |
Max 2.0 mm |
Operating temperature |
-10 ... + 70 °C (-25 ... +85 °C |