Product Introduction
This testing machine is based onGB2099.1、GB16915、GB15092、UL498、UL310、UL817Developed according to relevant standards for other electrical accessories.
Temperature rise testing machineUsed for terminal temperature rise test and plug temperature rise test. The trial method is to short-circuit the positive and negative terminals of the plug or socket, connect the tail to the current output terminal, and then connect
After passing the current and setting the required test current and time according to the standard requirements, the temperature rise value of the rivet joint between the plug or socket and the conductor is tested after a certain period of time and current
Does the temperature rise value after loading meet the standard requirements and can automatically print and record the test temperature,Equipped with over temperature and over-current protection function, no manual duty is required.
main features
1.Touchscreen interface, fully Chinese user-friendly operation interface, reliable quality;
2.Insert on the panelUExport the temperature data from the disk for testing and transfer it to the computer for storageEXCELfile;
3.Test station: 6/9/12Workstation;
4.Two testing modes:Continuous testing(0-30000minute)Intermittent testing(0-30000second, ONduration0-120minute, OFFduration0-120minute);
5.Temperature channel: 6/9/12passageway+room temperature;
6.temperature range: 0-300℃/0.1℃,Temperature recording interval20s;
7.Standard test current:50Aresolving power:0.1A;
8.Protection alarm:Automatic shutdown due to overcurrent,Range of overcurrent alarm values: 0Maximum current value,Automatically record overcurrent time;Automatic shutdown due to overheating,Overtemperature alarm value0-300℃,Alarm communicationDao Touch
Touchscreen display and flashing,Automatically record overheating
technical parameter
Test parameters |
Operation interface |
7 "TFT touch screen |
|
|
Test mode |
Continuous/intermittent testing |
|
|
Open circuit voltage |
Less than AC12 volts |
|
|
Test current |
600A |
Optional |
|
electricStream resolution |
0.1A |
|
|
measuretryCurrent accuracy |
0.5level |
|
|
electricStream refresh rate |
Once/second |
|
|
Current frequency |
50Hzor60Hz |
Same power frequency |
Temperature parameters |
Temperature sensing line |
U.S.AOMEGA 30AWG fine wire thermocouple |
|
|
Temperature measurement channel |
6 +1 CH |
cansetsystem |
|
temperature range |
0-150/300centigrade |
|
|
Temperature divisionResolution |
01 degree Celsius |
|
|
temperaturemeasureTest precisiondegree |
0Level 2 |
canchoose |
|
temperaturesampling rate |
8ch/s |
|
|
dataRecord cycle |
10 s |
|
|
Temperature storage roomSeparated |
60 minutes or immediately |
|
|
Temperature data storage |
Save electronic files to USB drive |
Can be converted from PC to storageEXCEL document |
technical specifications
model |
Workstation |
Test voltage |
Current range |
temperature range |
Power capacity |
weight |
8108-6-50 |
6individual |
≤12V |
0-50.0A |
0-300.0℃ |
1KVA |
30KG |
8108-9-50 |
9individual |
≤12V |
0-50.0A |
0-300.0℃ |
1KVA |
35KG |
8108-12-50 |
12individual |
≤14V |
0-50.0A |
0-300.0℃ |
1KVA |
38KG |
8108-6-150 |
6individual |
≤12V |
0-150.0A |
0-300.0℃ |
2KVA |
60KG |
8108-9-150 |
9individual |
≤12V |
0-150.0A |
0-300.0℃ |
2KVA |
65KG |
8108-6-350 |
6individual |
≤12V |
0-350.0A |
0-300.0℃ |
5KVA |
90KG |
8108-6-600 |
6individual |
≤12V |
0-600.0A |
0-300.0℃ |
10KVA |
130KG |