Shanghai Jinxiao Electronics Co., Ltd
Home>Products>LD-6S Multi functional Precision Laser Dust Analyzer
LD-6S Multi functional Precision Laser Dust Analyzer
LD-6S Multi functional Precision Laser Dust Analyzer
Product details

A patented product of the new generation laser particle analyzer with continuous automatic humidity correction function. LD-6S is portable, and LD-6S (R) is online.

This instrument can effectively reduce humidity interference, achieve high precision, high sensitivity, wide range, and compatibility with various particle cutters such as PM10, PM5, PM2.5, and PM1.0. The instrument is equipped with a Φ 40mm filter membrane sampling device, which can collect particulate matter samples while continuously monitoring, and has functions such as data processing, storage, timed sampling, and dust over limit alarm. This instrument is particularly suitable for continuous online monitoring of particulate matter 24/7, as well as serving as a replacement product for existing dust meters.

Main technical performance indicators:

(1) ★★★haveCPAThe certificate can be sent for inspection to a national metrology institute.

(2)★★configuration40mmFilter membrane online sampler;Certified as a high-tech enterprise.It has the function of continuous humidity automatic correction; Equipped with a filter membrane sampler unit, it enables continuous monitoring of dust concentration and compatibility with filter membrane sampling;The instrument is equipped with a calibrated self calibration device with optical stability. Particulate matter capture characteristics Da50=10 µ m+0.5 µ m, σ g=1.5 ± 0.1

(3)Cutting particle size: PM10, PM5, PM2.5, PM1.0, TSP, compatible with total dust;Volume: 198 * 118 * 98
(4) Detection sensitivity: 0.001mg/m3;0.01 mg/m3

(5) Measurement range: 0.001-10 mg/m3 0.01―100 mg/m3

(6)Measurement accuracy: ± 10%;

(7)Repetitive error ± 2%;

(8)Measurement time: The standard time is 1 minute, and there are also 0.1 minutes and manual modes available;

(9)Timed sampling: measurement time (1-9999 seconds), shutdown time (0-9999 seconds), and sampling frequency (1-9999 times) can be set;

(10) Alarm threshold setting for excessive dust concentration: concentration threshold<65mg/m3Measurement time: 1-9999 seconds;

(11) Output interface:

--PCSerial interface for machine communication: RS232;

--Micro printer output interface;

(12)Power supply: Ni MH rechargeable battery, can be used continuously for 8 hours, equipped with a power adapter.

Main technical features

  1. ★★Designed a replaceable particle cutter and achievedPM10PM5PM2. 5PM1TSPMultiple particle separation cutters compatible with total dust.
  2. Designed an online filter membrane sampler that is compatible with continuous monitoring of dust concentration and filter membrane sampling. It can analyze the composition of collected particles and calculate the mass concentration conversion coefficient of the siteKValue.
  3. Using a laser light source, the conversion coefficient of mass concentration is not affected by the color of particles.
  4. Adopting a large screen LCD display of Chinese characters, Chinese character menu prompts have been implemented.
  5. Designed a constant current controller, Ensure a constant sampling flow rate and correct cutting curve.
  6. Equipped with built-in optical standard scatter board,Ensure high stability of the instrument.
  7. Featuring a special protective air curtain, it prevents dust from damaging the core components of the instrumentPollution from optical systems ensures high reliability of instruments .
  8. The automatic zero adjustment of the instrument is achieved through computer software, which improves the measurement accuracy of the instrument and facilitates user use.
  9. The instrument is designed with a timed sampling mechanism, which can perform timed sampling, start and stop according to the set time. The obtained data can be obtained through Micro printer records or importsPCThe machine processes data to make the instrument suitable for continuous monitoring of inhalable particulate matter in the atmospheric environment.
  10. The instrument can set an alarm threshold for dust concentration exceeding the standard. When the dust exceeds the standard, it will automatically sound and light an alarm, or transmit the signal to the control center Conduct monitoring.
  11. The instrument is designed with an analog output interface, which can draw a purification efficiency evaluation curve when evaluating the air purifier.
  12. In addition to the general measurement mode suitable for dust monitoring in indoor public places and the timed sampling mode suitable for atmospheric environment monitoring, a new labor hygiene mode has been added. In this mode, according to the hygiene standards of industrial enterprises(GBZ1-2002)Exposure limit standards for harmful factors in the workplace(GBZ2-2007)Calculate the time weighted average(TWA)And the allowable concentration for short-term exposure(STEL).

Online inquiry