KH series public place system testing box
Public place detection system box
Product details

Description of Public Place Detection System Box

One:Public place detection system boxusing objects

Currently, the staff of China's health and epidemic prevention stations and environmental monitoring stations are affected by the special nature of measurement services. It is necessary to go to the measurement site to quickly and accurately measure the environmental conditions and the content of pollutants in the air. In the past, due to outdated instruments, it was often necessary to go to the measurement site for sampling and then return to the laboratory for analysis, which brought a lot of workload.

Now, the public place detection system box produced by our company integrates the most advanced instruments produced by foreign countries and our company according to the needs of users, and combines them into an advanced detection box, allowing staff to go out of the laboratory and directly measure the required data on site, increasing the evidence directness and strength of law enforcement personnel

Secondly:Public place detection system boxSpecifications and Configuration

There are four models of public place detection system boxes produced by our company:

(1) ET-1 type: contains the following instruments

Serial Number

model

Instrument Name

Technical parameters (range, accuracy)

1

T40

Palm type carbon monoxide analyzer

Range: 0-1000ppm, accuracy: 1ppm

2

CEA-700

Infrared carbon dioxide analyzer

Range: 0-10000ppm, accuracy: 1ppm

3

TES1332

digital luxmeter

Range: 0.01-20000Lux

4

TES1350

Digital sound level meter

35-130dbAccuracy: 0.1db

5

TES1360

Digital temperature and humidity meter

10%-95%-20 ℃ -+60 ℃

6

AVM-01

Digital anemometer

Range: 0-45m/s, accuracy: 0.1

(2) ETType 2: Contains the following instruments

Serial Number

model

Instrument Name

Technical parameters (range, accuracy)

1

Z-500

Palm type carbon monoxide analyzer

Range: 0-100ppm, accuracy: 0.1ppm

2

7001America

Infrared carbon dioxide analyzer

Range: 0-10000ppm, accuracy: 1ppm

3

TES1332

digital luxmeter

Range: 0.01-20000Lux

4

TES1350

Digital sound level meter

35-130dbAccuracy: 0.1db

5

TES1360

Digital temperature and humidity meter

10%-95%-20 ℃ -+60 ℃

6

AVM-01

Digital anemometer

Range: 0-45m/s, accuracy: 0.1

Similar products include:

2、 Public place detection system boxMicroclimate detection instruments

Instrument selection for detection system box

price

carbon dioxide

carbon monoxide

TH-CALC

Noise meter

lumeter

anemometer

CEA-700

T40

TES-1360

TES-1350A

TES-1330

AVM-01

29800

-7001

Z-500

TES-1360

TES-1350A

TES-1332

BYWF-2001

32900

Same as above, with additional radiation meter

42900

Indoor pollution detection system box

Can measure simultaneously (formaldehyde analyzer, ammonia analyzer, radon analyzer, carbon dioxide)