PCD-430A sensor interface amplifier

-----------------------------------------------------------------------

Summary

Just go throughUSBA measuring device that can be connected to a computer through an interface for measurement.
Through stack type connections, it can be easily extended to16A channel.

feature

Input strain and voltage can be selected for each channel
● Easy sensor connection based on abundant input adapters (1 input adapter is required for measurement)
The USB interface is used to connect to a personal computer
Possible measurement with 1 unit of 4 channels and a maximum of 4 units of 16 channels (allowing for a combination of PCD-400A)
● Conduct simultaneous sampling and investigation of 4 units using connector sets sold separately
Dynamic Data Set Recording Software (DCS-100A) Standard Accessory for Windows Vista, Windows 7, Windows 8, 8.1 (Japanese/English, 32/64 bits)
● TEDS Corresponding (UI-10A, UI-11A)
● Input adapter
Input adapter UI-10A for strain gauge sensors (corresponding to TEDS)
Strain gauge input adapter UI-11A (corresponding to TEDS)
Input adapter UI-15A with operating rod strain gauge
Input adapter UI-16A for single touch locking strain gauges
One touch input adapter UI-55A
Voltage input adapter UI-30A
● Small and lightweight
● Data analysis can be performed by selecting analysis software (DAS-200A, NI DIAdem)

Product Overview

Comprehensive specifications

Number of measurement channels 4
Synchronize operation Up to a maximum of 4 units with 16 channels
sampling Sampling frequency: maximum 10kHz (when set to 10kHz, 4 sets of 16 channels can be measured synchronously)
AD converter resolution 24 digits
Maintaining the set value The range and balance adjustment values are saved in the internal non-volatile memory
TEDS function Read information from TEDS sensors (input adapter: only UI-10A, UI-11A is valid)
There is a function to write channel names (valid when the manufacturer's ID is Gonghe Electric)
interface USB 2.0 (High Speed specification, can also work with USB 3.0)
Temperature and humidity range for use 0-40 ℃, 20-85% RH (no condensation)
Vibration resistance ± 29.42 m/s2 (3G), 5-200Hz (12 cycles per axis, 10 minutes per cycle)
power supply DC11~16V
Joint type: RM12BRD-4PH (Hirose Electric Co., Ltd.)
current consumption Below 0.9A (DC12V)
Dimensions of appearance 210 (W) × 35 (H) × 157.5 (D) mm (excluding protruding parts)
weight About 750g

Specifications

Applicable specifications

EMC Directive EN61326-1 (Class A)
RoHS Directive EN50581

Strain measurement mode

measurement object Strain gauges, strain gauge sensors
input format Balanced differential input
Suitable for strain gauge resistors 1/4 bridge method (2-wire, 3-wire) 120 Ω
Half bridge type, full bridge type 120 Ω~1000 Ω
Bridge power supply AC 2Vrms
strain rate 2.00 Fixed
Balance adjustment range Resistance: ± 2% (± 10000 × 10-6 strain) or less
Capacitor: 5000pF or below
Balance adjustment method Resistance: Pure electronic automatic balancing method
Capacitor: CST mode (automatic tracking)
nonlinear ± 0.1% FS or less
measurement range 200,500,1000,2000,5000,10000,20000×10-6The 7 segments of the dependent variable
Accuracy: ± 0.5% FS or below
Response frequency range DC~200Hz, Deviation within ± 10% or less
low-pass filter Communication characteristics: 2nd order Butterworth type
Cut off frequency: 10,30100Hz and 4 segments of FLAT
Amplitude ratio at the cut-off point: -3 ± 1dB
Attenuation characteristics: -12 ± 1 dB/oct.
stability temperature
Zero point: ± 0.2 × 10-6Strain/℃
Sensitivity: ± 0.05%/℃
time
Zero point: ± 0.5 × 10-6Dependent variable/8h
Sensitivity: ± 0.15%/8h
Insulation pressure resistance Input - Between Chassis
AC250V, 1 minute

Voltage measurement mode

measurement object voltage
input format Unbalanced input
measurement range 6 sections of 1, 2, 5, 10, 20, and 50 V
精度: ±0.2%FS 以内
Response frequency range DC ~ 1kHz, Deviation -3 to+1dB or less
high-pass filter Cut off frequency: 0.2Hz, 2 segments of OFF
low-pass filter Communication characteristics: 2nd order Butterworth type
Cut off frequency: 10, 30, 100, 300 Hz and 5 segments of FLAT
Amplitude ratio at the cut-off point: -3 ± 1dB
Attenuation characteristics: -12 ± 1 dB/oct.
stability temperature
Zero point: ± 0.008% FS/℃
Sensitivity: ± 0.02%/℃
time
Zero point: ± 0.03% FS/8h
Sensitivity: ± 0.1%/8h

Standard Accessories

Standard Accessories USB cable N-38 (1m)
Grounding wire P-72 (5m)
DVD (Dynamic Data Control Software DCS-100A)

Choose accessories

Choose accessories AC adapter UIA345-12
USB cable N-39 (2m)
DC power cable P-76 (DC 11-16V, 2m)
Connecting cable N-97 (10cm)
Connection connector device (ST-1A)
Connection board (CN-20)
Input adapter UI-10A for strain gauge sensors (compatible with TEDS)
Strain gauge input adapter UI-11A (compatible with TEDS)
Input adapter UI-15A with operating rod strain gauge
Input adapter UI-16A for single touch locking strain gauges
One touch input adapter UI-55A
Voltage input adapter UI-30A